SCU224 Adjustment Channels Channel Description Arr x System DT O x Switch-on temperature difference DT F x Switch-off temperature difference DT S x Nominal temperature difference RIS x Rise control R1 n1MN x Minimum pump speed R1 S MX x Maximum tank temperature Emergency temperature collector EM x Emergency temperature collector if ODB is activated: OCC x Option collector cooling CMX x* Maximum collector temperature OSYC x Option system cooling DTCO x* Cooling switch-on temperature difference DTCF x* Cooling switch-off temperature difference OSTC x Option tank cooling OHOL x* Option holiday cooling THOL x* Holiday cooling temperature OCN x Option minimum limitation CMN x* Minimum collector temperature OCF x Option antifreeze CFR x* Antifreeze temperature O TC x Option tube collector TCST x* OTC starting time TCEN x* OTC ending time TCRU x* OTC runtime TCIN x* OTC standstill interval OHQM x Option energy metering FMAX x* Maximum flow MEDT x* Antifreeze type MED% x* Antifreeze concentration AH O s Switch-on temp. for thermostat 1 AH F s Switch-off temp. for thermostat 1 t1 O s Switch-on time 1 thermostat t1 F s Switch-off time 1 thermostat t2 O s Switch-on time 2 thermostat t2 F s Switch-off time 2 thermostat t3 O s Switch-on time 3 thermostat t3 F s Switch-off time 3 thermostat ODB x Drainback option tDTO x* ODB switch-on condition - time period tFLL x* ODB filling time tSTB x* ODB stabilization time OTD s Option thermal disinfection PDIS s* Monitoring period DDIS s* Heating period TDIS s* Disinfection temperature SDIS s* Starting time MAN1 x Manual operation R1 MAN2 x Manual operation R2 LANG x Language UNIT x Temperature unit RESE x Reset - back to factory defaults W0050100 Version number Factory setting 3 12.0 °Ra [6.0 K] 8.0 °Ra [4.0 K] 20.0 °Ra [10.0 K] 4 °Ra [2 K] 30 % 140 °F [60 °C] 270 °F [130 °C] 200 °F [95 °C] OFF 230 °F [110 °C] OFF 40.0 °Ra [20.0 K] 30.0 °Ra [15.0 K] OFF OFF 110 °F [40 °C] OFF 50 °F [10 °C] OFF 40.0 °F [4.0 °C] OFF 07:00 19:00 30 s 30 min OFF 6.0 l 1 45 % 110 °F [40 °C] 120 °F [45 °C] 00:00 00:00 00:00 00:00 00:00 00:00 OFF 60 s 5.0 min 2.0 min OFF 01:00 01:00 140 °F [60 °C] 00:00 Auto Auto En °C Page 39 39 39 39 39 39 40 40 40 41 41 41 41 41 42 42 42 42 42 42 42 44 44 44 44 44 44 44 44 44 14 14 14 14 14 14 14 14 45 45 45 45 15 15 15 15 15 46 46 46 46 46 © Viessmann 5443203 Legend: Symbol Specification x Channel is available x* Channel is available if the corresponding option is activated. s Channel is specifically available in this system layout s* System-specific channel, only available if the corresponding option is activated 13 |