Download Wolf 1524 Specifications

Transcript
I N S TA L L AT I O N I N S T R U C T I O N S
48" (1219) G A S R A N G E S
28 3/8" (721)
OVERALL DEPTH
27 1/4" (692)
9 1/4"
(235)
56 3/4"
OVERALL DIMENSIONS
(1441)
WITH 20"
RISER
Overall Width
46 3/4"
24 1/2" (622)
(1187)
WITH 10"
RISER
37" (940)
36"
OVERALL
HEIGHT TO
COOKING
SURFACE
(914)
48" (1219)
Overall Height
(to cooking surface)
41 3/4"
(1060)
WITH 5"
RISER
Overall Depth
Opening Width
37" (940)
28 3/8" (721)
48 1/4" (1226)
Unit dimensions may vary by ± 1/8" (3).
2 1/2"
(64)
25 1/4" (641)
48" (1219)
OVERALL WIDTH
43 3/8" (1102)
LEGS AND CASTERS ALLOW
1" (25) HEIGHT ADJUSTMENT
I N S TA L L AT I O N S P E C I F I C AT I O N S
IMPORTANT NOTE:
A minimum 5" (127)
riser is required
when installing a gas
range against a
combustible surface.
A minimum 10" (254)
riser is required
when installing a
gas range with a
charbroiler or
griddle against a
combustible surface.
VENTILATION HOOD
30"min (762)
COUNTERTOP
TO COMBUSTIBLE
MATERIALS
6" min (152)
TO
COMBUSTIBLE
MATERIALS
(BOTH SIDES)
30"(762) TO 36"(914)
13" max
COUNTERTOP TO
BOTTOM OF
VENTILATION HOOD
36"min (914)
FOR CHARBROILER
(330)
18"min (457)
TO COUNTERTOP
481/4" (1226)
FINISHED ROUGH OPENING WIDTH
36"
(914)
26"
12"
(660)
(305)
8"
(203)
37"
(940) TO
COOKING
SURFACE
E
2"
(51)
51/2"
(140)
G
12"
5"
(305)
(127)
3"
LOCATION OF GAS SUPPLY EXTENDS
3" (76) ON FLOOR FROM BACK WALL
(76)
ISLAND INSTALLATIONS: 12" (305) MINIMUM CLEARANCE FROM BACK
OF RANGE TO COMBUSTIBLE REAR WALL ABOVE COUNTERTOP –
0" (0) TO NON-COMBUSTIBLE MATERIALS
Dimensions in parentheses are in
millimeters unless otherwise specified.
9