Download Sharp SF-1020 Service manual
Transcript
2-2. Note for adjustments 1. Only the exposure balance adjustment, the blank lamp adjustment, and the copy lead edge adjustment can be performed individually. For the other adjustments, follow the flowchart below. 1. Mechanical reference position adjustment (without copying) A. No. 2/3 mirror unit parallelism adjustment Vertical skew copy adjustment --- Manual adjustment B. Check the following preset values according to the lens focus rank. Lens reference position adjustment --- SIM 48-01 No. 4/5 mirror reference position adjustment --- Manual adjustment 2. Adjustment while copying 1. Image distortion, center shift check NO Image distortion Vertical skew copy adjustment Horizontal skew copy adjustment Center shift: Lens center shift adjustment YES 2. Normal (x 1.00), zooming (x 2.00) resolution (focus) check NO Resolution (focus) adjustment Normal: Adjust with the No. 4/5 mirror adjustment screw. Zooming: Adjust with the zooming cam. YES 3. Normal copy magnification ratio (vertical, horizontal) check NO Copy magnification ratio adjustment Vertical copy magnification ratio adjustment Horizontal copy magnification ratio adjustment YES 4. Exposure balance, blank lamp position, lead edge variation check YES END 7–3 NO Exposure balance adjustment Blank lamp position adjustment Copy lead edge adjustment (Including the void area adjustment.)