VLT® 8000 AQUA ■ Application functions 400-434 401 Automatic restart time (AUTORESTART TIME) Value: 0 - 1800 sec. Includes this parameter group, the special functions of the frequency converter PID regulation, setting of the feedback range and the Setup of the Sleep mode function. Additionally, this parameter group includes: - Reset function. - Flying start. - Option of interference reduction method. - Setup of any function upon loss of load, e.g. because of a damaged V-belt. - Setting of switching frequency. - Selection of process units. ✭ 10 sec. Function: This parameter allows setting of the time from tripping until the automatic reset function begins. It is assumed that automatic reset has been selected in parameter 400 Reset function. Description of choice: Set the desired time. 402 Flying start (FLYING START) Value: ✭Manual reset (MANUAL RESET) Automatic reset x 1 (AUTOMATIC X 1) Automatic reset x 2 (AUTOMATIC X 2) Automatic reset x 3 (AUTOMATIC X 3) Automatic reset x 4 (AUTOMATIC X 4) Automatic reset x 5 (AUTOMATIC X 5) Automatic reset x 10 (AUTOMATIC X 10) Automatic reset x 15 (AUTOMATIC X 15) Automatic reset x 20 (AUTOMATIC X 20) Infinite automatic reset (INFINITE AUTOMATIC) [0] [1] [2] [3] [4] [5] [6] [7] [8] [9] Function: This parameter allows a choice of whether to reset and restart manually after a trip, or whether the frequency converter is to be reset and restarted automatically. In addition, there is a choice of the number of times the unit is to attempt a restart. The time between each reset attempt is set in parameter 401 Automatic restart time. Description of choice: If Manual reset [0] is selected, resetting must be effected via the "Reset" key or via a digital input. If the frequency converter is to carry out an automatic reset and restart after a trip, select data value [1]-[9]. Value: ✭Disable (DISABLE) Enable (ENABLE) DC brake and start (DC BRAKE AND START) [0] [1] [3] Function: This function makes it possible for the frequency converter to "catch" a spinning motor, which - e.g. because of a mains failure - is no longer controlled by the frequency converter. This function is activated whenever a start command is active. For the VLT frequency converter to be able to "catch" the spinning motor, the motor speed must be lower than the frequency that corresponds to the frequency in parameter 202 Output frequency high limit, fMAX. Description of choice: Select Disable [0] if this function is not required. Select Enable[1] if the VLT frequency converter is to be able to "catch" and control a spinning motor. Select DC brake and start [2] if the VLT frequency converter is to brake the motor with DC braking, and then restart the motor. It is assumed that parameters 114-116 DC braking are enabled. In the case of a substantial "windmilling" effect (spinning motor), the VLT frequency converter will not "catch" a spinning motor unless DC brake and start has been selected. The motor may start without warning. ✭ = factory setting. () = display text [] = value for use in communication via serial communication port MG.83.A2.02 - VLT is a registered Danfoss trademark 131 Programming 400 Reset function (RESET FUNCTION)