Download 8501028 ACEX-FP-IO-XX User`s Manual

Transcript
ACEX-FP-IO-0x
COM Express Front Panel Board for
Ruggedized/Military Packaging
With Support for I/O Mezzanine Board
USER’S MANUAL
ACROMAG INCORPORATED
30765 South Wixom Road
Wixom, MI 48393-2417 U.S.A.
Tel: (248) 295-0310
Fax: (248) 624-9234
Copyright 2015, Acromag, Inc., Printed in the USA.
Data and specifications are subject to change without notice.
8501028B
ACEX-FP-IO-0x User’s Manual
COM Express Front Panel for Ruggedized/Military Packaging
The information contained in this manual is subject to change without notice. Acromag, Inc. makes no
warranty of any kind with regard to this material, including, but not limited to, the implied warranties of
merchantability and fitness for a particular purpose. Further, Acromag, Inc. assumes no responsibility for any
errors that may appear in this manual and makes no commitment to update, or keep current, the information
contained in this manual.
No part of this manual may be copied or reproduced in any form, without the prior written consent of
Acromag, Inc.
IMPORTANT SAFETY CONSIDERATIONS
It is very important for the user to consider the possible adverse effects of power, wiring, component,
sensor, or software failures in designing any type of control or monitoring system. This is especially
important where economic property loss or human life is involved. It is important that the user employ
satisfactory overall system design. It is agreed between the Buyer and Acromag, that this is the Buyer's
responsibility.
Acromag, Inc. Tel: 248-295-0310
-2-
www.acromag.com
ACEX-FP-IO-0x User’s Manual
COM Express Front Panel for Ruggedized/Military Packaging
Table of Contents
1.0 General Information ....................................................................................... 5
Key Features ................................................................................................................................... 6
2.0 Ordering Information .................................................................................... 6
3.0 Preparation for Use ........................................................................................ 7
Unpacking and Inspecting ................................................................................................................ 7
4.0 Operation ............................................................................................................ 8
Operational Block Diagram .............................................................................................................. 8
ACEX-FP-IO-01 – Board layout ......................................................................................................... 9
ACEX-FP-IO-02 – Board layout ....................................................................................................... 10
ACEX-IO – Board layout .................................................................................................................. 11
Mezzanine Board Interface ............................................................................................................ 13
5.0 Connector Pin-out ........................................................................................ 15
J1 (200 – Pin SEARAY Connector) ................................................................................................... 15
J2 (500 – Pin SEARAY Connector) ................................................................................................... 20
J3 – Keyed-A (130-Pin size #23 38999 Connector) ......................................................................... 33
J4 – Keyed-B (130-Pin size #23 38999 Connector) ......................................................................... 34
J5 – Keyed-C (130-Pin size #23 38999 Connector) ......................................................................... 35
J6 – Keyed-A (6-Pin size #12 38999 Connectors) ........................................................................... 36
J7 (160-Pin SEARAY Mezzanine Connector) ................................................................................... 36
J8 (160-Pin SEARAY Mezzanine Connector) ................................................................................... 37
J9 (160-Pin SEARAY Mezzanine Connector) ................................................................................... 38
J10 (160-Pin SEARAY Mezzanine Connector) ................................................................................. 39
Handling ........................................................................................................................................ 40
ESD Safe Work Area Guidelines ..................................................................................................... 40
6.0 Service and Repair ....................................................................................... 41
Service and Repair Assistance ........................................................................................................ 41
Preliminary Service Procedure ....................................................................................................... 41
Where to Get Help ......................................................................................................................... 41
7.0 Specifications ................................................................................................. 42
Physical........................................................................................................................................... 42
Acromag, Inc. Tel: 248-295-0310
-3-
www.acromag.com
ACEX-FP-IO-0x User’s Manual
COM Express Front Panel for Ruggedized/Military Packaging
Power Requirements...................................................................................................................... 42
Environmental ................................................................................................................................ 42
Appendix...................................................................................................................... 43
500 - Pin SEARAY Connector pin-out by Type ................................................................................ 43
#23, 130 Pin 38999 keyed-B, Peripheral connector pin out (front view) ...................................... 56
#23, 130 Pin 38999 keyed-A and C, I/O connector pin out (front view) ........................................ 57
38999 Crimping Tools .................................................................................................................... 58
PCB Mechanical Drawings .............................................................................................................. 59
Bill of Materials .............................................................................................................................. 61
Schematic ....................................................................................................................................... 61
Mezzanine Board Installation......................................................................................................... 62
Certificate of Volatility .......................................................................................... 64
Revision History ....................................................................................................... 65
Acromag, Inc. Tel: 248-295-0310
-4-
www.acromag.com
ACEX-FP-IO-0x User’s Manual
1.0
COM Express Front Panel for Ruggedized/Military Packaging
General Information
The ACEX-FP-IO-0x is a front panel board that provides the I/O interface for the ARCX-4xxx
product family via the 38999 type connections. The ACEX-FP-IO-0x board connects to the ACEX-46xx
Carrier via high-speed, high-density ruggedized SEARAY connector. The signals are then passed thru to
the XCOM-6400 CPU module via COM Express connector. The ACEX-FP-IO-0x front panel boards
supports the use of custom mezzanine modules through the use of ultra-high-density SEARAY
connectors.
Models:
ACEX-FP-IO-01 (Single wide)


Two high-density 130-pin circular 38999 type connectors
o
One Peripheral I/O
o
One PMC/XMC rear I/O
One 6-Pin circular 38999 type connectors
o
Power input
o
Power On switch
ACEX-FP-IO-02 (Double wide)


Three high-density 130-pin circular 38999 type connectors
o
One Peripheral I/O
o
Two PMC/XMC rear I/O
One 6-Pin circular 38999 type connectors
o
Power input
o
Power On switch
Note: Single wide / Double wide refers to the number of supported PMC/XMC rear I/O slots available
which is determined by the use of a single wide or double wide ACEX-46xx Carrier board. i.e. the double
wide carrier board has two PMC/XMC expansion sites available.
The XMC rear I/O supports the UD (user defined) signals as defined in the ANSI/VITA 42.0 specifications.
The DPxx+ and DPxx- signals are not brought out the 130-Pin 38999 connector.
Acromag, Inc. Tel: 248-295-0310
-5-
www.acromag.com
ACEX-FP-IO-0x User’s Manual
COM Express Front Panel for Ruggedized/Military Packaging
Key Features

Provides access to standard peripherals of the Type 6 COM Express CPU through high-density
ruggedized connector.
o
Two HDMI/DVI ports
o
One VGA port
o
Three USB 2.0 Ports
o
Two RS-232/422/485 Communication ports
o
One SATA port
o
Two Gigabit Ethernet Ports
o
Audio (One Line in and One Line out)
o
Fault/Status LED

Provides Rear I/O connections to PMC/XMC expansion cards on the ACEX-46xx carrier through
high-density ruggedized connector(s).

Supports the use of mezzanine modules that interface between the system and the PMC/XMC Rear
I/O 38999 connectors.

Designed to meet requirements of MIL-STD-810F environmental specification.
2.0
Ordering Information
ACEX-FP-IO-xx
xx =
ACEX-IO
01 = Single Wide – Supports one PMC/XMC Rear I/O sites
02 = Double Wide – Supports two PMC/XMC Rear I/O sites
Pass-through Mezzanine Board
Front Panel Accessories (optional)
5028-556
38999 #23 size , CPU I/O Peripheral Breakout Cable
5028-557
38999 #12 size , Power Cable
5028-558
38999 #23 size Keyed “A” mating cable connector only
5028-559
38999 #23 size Keyed “C” mating cable connector only
5028-560
38999 #23 size Keyed “B” mating cable connector only
5028-561
38999 #12 size Keyed A mating cable connector only
5028-566
38999 #23 size, PMC/XMC Site 1 Rear I/O Breakout Cable
5028-567
38999 #23 size, PMC/XMC Site 2 Rear I/O Breakout Cable
Note: 5028-566 and 5028-567 cables intended for use with two 5025-288 SCSI-3 termination panels
Acromag, Inc. Tel: 248-295-0310
-6-
www.acromag.com
ACEX-FP-IO-0x User’s Manual
3.0
COM Express Front Panel for Ruggedized/Military Packaging
Preparation for Use
Unpacking and Inspecting
Upon receipt of this product, inspect the shipping carton for evidence of
mishandling during transit. If the shipping carton is badly damaged or water
stained, request that the carrier's agent be present when the carton is
opened. If the carrier's agent is absent when the carton is opened and the
contents of the carton are damaged, keep the carton and packing material
for the agent's inspection.
WARNING: This board utilizes
static sensitive components
and should only be handled at
a static-safe workstation.
Acromag, Inc. Tel: 248-295-0310
For repairs to a product damaged in shipment, refer to the Acromag Service
Policy to obtain return instructions. It is suggested that salvageable shipping
cartons and packing material be saved for future use in the event the
product must be shipped.
This board is physically protected with packing material and electrically
protected with an anti-static bag during shipment. However, it is
recommended that the board be visually inspected for evidence of
mishandling prior to applying power.
-7-
www.acromag.com
ACEX-FP-IO-0x User’s Manual
4.0
COM Express Front Panel for Ruggedized/Military Packaging
Operation
Operational Block Diagram
Acromag, Inc. Tel: 248-295-0310
-8-
www.acromag.com
ACEX-FP-IO-0x User’s Manual
COM Express Front Panel for Ruggedized/Military Packaging
ACEX-FP-IO-01 – Board layout
Acromag, Inc. Tel: 248-295-0310
-9-
www.acromag.com
ACEX-FP-IO-0x User’s Manual
COM Express Front Panel for Ruggedized/Military Packaging
ACEX-FP-IO-02 – Board layout
Acromag, Inc. Tel: 248-295-0310
- 10 -
www.acromag.com
ACEX-FP-IO-0x User’s Manual
COM Express Front Panel for Ruggedized/Military Packaging
ACEX-IO – Board layout
Acromag, Inc. Tel: 248-295-0310
- 11 -
www.acromag.com
ACEX-FP-IO-0x User’s Manual
COM Express Front Panel for Ruggedized/Military Packaging
J3 is a 130-pin size #23 38999 type connector, keyed – A. This connector provides access to the Rear I/O
coming from the PMC/XMC site on the carrier board (ACEX-46xx). If a PMC P4/J4 connector is used/installed in
site 1 on the carrier board than all 32 differential Pairs of Rear I/O signals are available thru J3. If an XMC
card P15 connector is used/installed in site 1 of the carrier board than the UD (user defined signals) Row C and
F of the XMC boards P16 connector as defined in VITA 42.0 signals are available.
J4 is a 130-pin size #23 38999 type connector, keyed – B. This connector provides the following standard
peripheral I/O as shown below. Optional cable 5028-556 is available.
Acromag, Inc. Tel: 248-295-0310
- 12 -
www.acromag.com
ACEX-FP-IO-0x User’s Manual
COM Express Front Panel for Ruggedized/Military Packaging
J5 is a 130-pin size #23 38999 type connector, Keyed – C. This connector provides access to the Rear I/O
coming from the PMC/XMC site on the carrier board (ACEX-46xx). If a PMC P4/J4 connector is used/installed in
site 2 on the carrier board than all 32 differential Pairs of Rear I/O signals are available thru J3. If an XMC
card P15 connector is used/installed in site 2 of the carrier board than the UD (user defined signals) Row C and
F of the XMC boards P16 connector as defined in VITA 42.0 signals are available.
J6 is a 6-pin size #12 38999 type connector, keyed - A. This connector is used to provide External input power
10V to 36VDC to the Carrier (ACEX-46xx). This connector also provides PWR_BTN line to allow the user to use
a power switch. Optional cable 5028-557 is available.
J7 and J8 are high-density connectors that provide the mezzanine board interface for 38999 connector J3.
The PMC/XMC Rear I/O signals from Site 1 on the carrier board (ACEX-46xx) are routed up to the mezzanine
interface on J8 and then back down on J7 before being sent out the 38999 connector J3. The ACEX-FP-IO-0x
boards require the use of a mezzanine board on J7/J8 in order to provide connections for the signals being
routed to the 38999 connector J3. A “pass-through” mezzanine board is included on standard models that allow
the PMC/XMC Rear I/O signals to be routed directly out the 38999 connector J3. A design kit for developing
custom mezzanine boards is available upon request.
J9 and J10 are high-density connectors that provide the mezzanine board interface for 38999 connector
J5. The PMC/XMC Rear I/O signals from Site 2 on the carrier board (ACEX-46xx) are routed up to the mezzanine
interface on J10 and then back down on J9 before being sent out the 38999 connector J5. The ACEX-FP-IO-0x
boards require the use of a mezzanine board on J9/J10 in order to provide connections for the signals being
routed to the 38999 connector J5. A “pass-through” mezzanine board is included on standard models that allow
the PMC/XMC Rear I/O signals to be routed directly out the 38999 connector J5. A design kit for developing
custom mezzanine boards is available upon request.
Mezzanine Board Interface
The ACEX-FP-IO-0x boards require the use of a mezzanine board on J7/J8 and J9/J10 in order to provide
connections for the signals being routed to the corresponding 38999 connectors J3 and J5, respectively. On
standard models, a “pass-through” mezzanine board is included for each of the mezzanine board sites on the
ACEX-FP-IO-0x boards. The “pass-through” mezzanine board simply routes the PMC/XMC Rear I/O signals
straight through to the 38999 connector. The “pass-through” mezzanine board is designed to be
interchangeable between the two mezzanine board sites.
In addition to the core set of PMC/XMC Rear I/O signals that are identical between the two sites, there
are a set of signals unique to each of the mezzanine board sites. On the J7/J8 mezzanine board (Site 1) there are
a variety of miscellaneous signals are available for use on custom mezzanine boards. These include PCIe lanes, a
SATA interface, GPIO signals, and I2C Bus lines. On the J9/J10 mezzanine board (Site 2) the additional pins are
used to bring up the rest of the PMC/XMC Rear I/O signals for use on custom mezzanine boards.
Acromag, Inc. Tel: 248-295-0310
- 13 -
www.acromag.com
ACEX-FP-IO-0x User’s Manual
COM Express Front Panel for Ruggedized/Military Packaging
Power LED
The Blue Power LED indicates DC 10V-36V power is applied at the external power input.
Status LED
The Status LED is Bi-color (RED/GREEN) LED that is used to show the status of the system power state S3 and
S4.
System Power State S3 the Sleep state:
All power is off except memory. If power is removed at this point you will lose your current session.
System Power State S4 the Hibernate state:
Safe to remove power, will always resume the current session when power is reapplied.
S3# and S4# are active low signals (# indicates active low). There are three basic states indicated by the Status
LED:
 Status LED steady “Green On” when the system is running.
 Status LED “Blink Green” when the system enters sleep state S3.
 Status LED will turn off when the system enters Sleep state S4 Hibernate.
Note: It is ok to remove power from the system when the Status LED is off.
Signal Activity
Sleep S3#
Sleep S4#
0
0
1
0
1
1
Status LED
Green On
Blink Green
LED Off



 - Condition of the Status LED
0 - Represents a Low state
1 - Represents a High state
Note: S5 State is not monitored by the LED however the Status LED will go off during a S5 or shutdown
condition.
SW2 – Reserved
SW2 is reserved for future use.
SW2 - Bold indicates default factory settings
SW2 - 1
ON
Reserved
OFF
Normal operation
SW2 - 2
ON
Reserved
OFF
Normal operation
SW2 - 3
ON
Reserved
OFF
Normal operation
SW2 - 4
ON
Reserved
OFF
Normal operation
Acromag, Inc. Tel: 248-295-0310
- 14 -
www.acromag.com
ACEX-FP-IO-0x User’s Manual
5.0
COM Express Front Panel for Ruggedized/Military Packaging
Connector Pin-out
J1 (200 – Pin SEARAY Connector)
Signal Name
VCC_5V_IN
J24_RIO3_P
J24_RIO3_N
J24_RIO7_P
J24_RIO7_N
J24_RIO10_P
J24_RIO10_N
J24_RIO14_P
J24_RIO14_N
J24_RIO17_P
J24_RIO17_N
J24_RIO21_P
J24_RIO21_N
J24_RIO24_P
J24_RIO24_N
J24_RIO28_P
J24_RIO28_N
J24_RIO31_P
J24_RIO31_N
EXT_PWR_OUT
J24_RIO1_P
J24_RIO1_N
J24_RIO5_P
J24_RIO5_N
J24_RIO8_P
J24_RIO8_N
J24_RIO12_P
J24_RIO12_N
J24_RIO15_P
J24_RIO15_N
J24_RIO19_P
J24_RIO19_N
J24_RIO22_P
J24_RIO22_N
J24_RIO26_P
J24_RIO26_N
Description
5V Input Voltage
PMC Site 2 Rear I/O Differential Pair "J24_RIO3+"
PMC Site 2 Rear I/O Differential Pair "J24_RIO3-"
PMC Site 2 Rear I/O Differential Pair "J24_RIO7+"
PMC Site 2 Rear I/O Differential Pair "J24_RIO7-"
PMC Site 2 Rear I/O Differential Pair "J24_RIO10+"
PMC Site 2 Rear I/O Differential Pair "J24_RIO10-"
PMC Site 2 Rear I/O Differential Pair "J24_RIO14+"
PMC Site 2 Rear I/O Differential Pair "J24_RIO14-"
PMC Site 2 Rear I/O Differential Pair "J24_RIO17+"
PMC Site 2 Rear I/O Differential Pair "J24_RIO17-"
PMC Site 2 Rear I/O Differential Pair "J24_RIO21+"
PMC Site 2 Rear I/O Differential Pair "J24_RIO21-"
PMC Site 2 Rear I/O Differential Pair "J24_RIO24+"
PMC Site 2 Rear I/O Differential Pair "J24_RIO24-"
PMC Site 2 Rear I/O Differential Pair "J24_RIO28+"
PMC Site 2 Rear I/O Differential Pair "J24_RIO28-"
PMC Site 2 Rear I/O Differential Pair "J24_RIO31+"
PMC Site 2 Rear I/O Differential Pair "J24_RIO31-"
External Output Power
PMC Site 2 Rear I/O Differential Pair "J24_RIO1+"
PMC Site 2 Rear I/O Differential Pair "J24_RIO1-"
PMC Site 2 Rear I/O Differential Pair "J24_RIO5+"
PMC Site 2 Rear I/O Differential Pair "J24_RIO5-"
PMC Site 2 Rear I/O Differential Pair "J24_RIO8+"
PMC Site 2 Rear I/O Differential Pair "J24_RIO8-"
PMC Site 2 Rear I/O Differential Pair "J24_RIO12+"
PMC Site 2 Rear I/O Differential Pair "J24_RIO12-"
PMC Site 2 Rear I/O Differential Pair "J24_RIO15+"
PMC Site 2 Rear I/O Differential Pair "J24_RIO15-"
PMC Site 2 Rear I/O Differential Pair "J24_RIO19+"
PMC Site 2 Rear I/O Differential Pair "J24_RIO19-"
PMC Site 2 Rear I/O Differential Pair "J24_RIO22+"
PMC Site 2 Rear I/O Differential Pair "J24_RIO22-"
PMC Site 2 Rear I/O Differential Pair "J24_RIO26+"
PMC Site 2 Rear I/O Differential Pair "J24_RIO26-"
Acromag, Inc. Tel: 248-295-0310
- 15 -
SEARAY Pin
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
A11
A12
A13
A14
A15
A16
A17
A18
A19
A20
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11
B12
B13
B14
B15
B16
www.acromag.com
ACEX-FP-IO-0x User’s Manual
J24_RIO29_P
J24_RIO29_N
RSVD
EXT_PWR_OUT
VCC_3.3V_IN
J24_RIO2_P
J24_RIO2_N
J24_RIO6_P
J24_RIO6_N
J24_RIO9_P
J24_RIO9_N
J24_RIO13_P
J24_RIO13_N
J24_RIO16_P
J24_RIO16_N
J24_RIO20_P
J24_RIO20_N
J24_RIO23_P
J24_RIO23_N
J24_RIO27_P
J24_RIO27_N
J24_RIO30_P
J24_RIO30_N
VCC_12V_IN
J24_RIO0_P
J24_RIO0_N
J24_RIO4_P
J24_RIO4_N
J26_SIO4_P
J26_SIO4_N
J24_RIO11_P
J24_RIO11_N
J26_SIO8_P
J26_SIO8_N
J24_RIO18_P
J24_RIO18_N
J26_SIO12_P
J26_SIO12_N
J24_RIO25_P
J24_RIO25_N
J26_SIO16_P
COM Express Front Panel for Ruggedized/Military Packaging
PMC Site 2 Rear I/O Differential Pair "J24_RIO29+"
PMC Site 2 Rear I/O Differential Pair "J24_RIO29-"
Reserved
External Output Power
3.3V Input Voltage
PMC Site 2 Rear I/O Differential Pair "J24_RIO2+"
PMC Site 2 Rear I/O Differential Pair "J24_RIO2-"
PMC Site 2 Rear I/O Differential Pair "J24_RIO6+"
PMC Site 2 Rear I/O Differential Pair "J24_RIO6-"
PMC Site 2 Rear I/O Differential Pair "J24_RIO9+"
PMC Site 2 Rear I/O Differential Pair "J24_RIO9-"
PMC Site 2 Rear I/O Differential Pair "J24_RIO13+"
PMC Site 2 Rear I/O Differential Pair "J24_RIO13-"
PMC Site 2 Rear I/O Differential Pair "J24_RIO16+"
PMC Site 2 Rear I/O Differential Pair "J24_RIO16-"
PMC Site 2 Rear I/O Differential Pair "J24_RIO20+"
PMC Site 2 Rear I/O Differential Pair "J24_RIO20-"
PMC Site 2 Rear I/O Differential Pair "J24_RIO23+"
PMC Site 2 Rear I/O Differential Pair "J24_RIO23-"
PMC Site 2 Rear I/O Differential Pair "J24_RIO27+"
PMC Site 2 Rear I/O Differential Pair "J24_RIO27-"
PMC Site 2 Rear I/O Differential Pair "J24_RIO30+"
PMC Site 2 Rear I/O Differential Pair "J24_RIO30-"
12V Input Voltage
PMC Site 2 Rear I/O Differential Pair "J24_RIO0+"
PMC Site 2 Rear I/O Differential Pair "J24_RIO0-"
PMC Site 2 Rear I/O Differential Pair "J24_RIO4+"
PMC Site 2 Rear I/O Differential Pair "J24_RIO4-"
XMC Site 2 Rear I/O Differential Pair "J26_SIO4+"
XMC Site 2 Rear I/O Differential Pair "J26_SIO4-"
PMC Site 2 Rear I/O Differential Pair "J24_RIO11+"
PMC Site 2 Rear I/O Differential Pair "J24_RIO11-"
XMC Site 2 Rear I/O Differential Pair "J26_SIO8+"
XMC Site 2 Rear I/O Differential Pair "J26_SIO8-"
PMC Site 2 Rear I/O Differential Pair "J24_RIO18+"
PMC Site 2 Rear I/O Differential Pair "J24_RIO18-"
XMC Site 2 Rear I/O Differential Pair "J26_SIO12+"
XMC Site 2 Rear I/O Differential Pair "J26_SIO12-"
PMC Site 2 Rear I/O Differential Pair "J24_RIO25+"
PMC Site 2 Rear I/O Differential Pair "J24_RIO25-"
XMC Site 2 Rear I/O Differential Pair "J26_SIO16+"
Acromag, Inc. Tel: 248-295-0310
- 16 -
B17
B18
B19
B20
C1
C2
C3
C4
C5
C6
C7
C8
C9
C10
C11
C12
C13
C14
C15
C16
C17
C18
C19
C20
D1
D2
D3
D4
D5
D6
D7
D8
D9
D10
D11
D12
D13
D14
D15
D16
D17
www.acromag.com
ACEX-FP-IO-0x User’s Manual
J26_SIO16_N
RSVD
VCC_12V_IN
VCC_3.3V_IN
J26_SIO1_P
J26_SIO1_N
J26_SIO3_P
J26_SIO3_N
J26_SIO5_P
J26_SIO5_N
J26_SIO7_P
J26_SIO7_N
J26_SIO9_P
J26_SIO9_N
J26_SIO11_P
J26_SIO11_N
J26_SIO13_P
J26_SIO13_N
J26_SIO15_P
J26_SIO15_N
J26_SIO17_P
J26_SIO17_N
VCC_5V_IN
J26_SIO0_P
J26_SIO0_N
GND
GND
J26_SIO2_P
J26_SIO2_N
GND
GND
J26_SIO6_P
J26_SIO6_N
GND
GND
J26_SIO10_P
J26_SIO10_N
GND
GND
J26_SIO14_P
J26_SIO14_N
COM Express Front Panel for Ruggedized/Military Packaging
XMC Site 2 Rear I/O Differential Pair "J26_SIO16-"
Reserved
12V Input Voltage
3.3V Input Voltage
XMC Site 2 Rear I/O Differential Pair "J26_SIO1+"
XMC Site 2 Rear I/O Differential Pair "J26_SIO1-"
XMC Site 2 Rear I/O Differential Pair "J26_SIO3+"
XMC Site 2 Rear I/O Differential Pair "J26_SIO3-"
XMC Site 2 Rear I/O Differential Pair "J26_SIO5+"
XMC Site 2 Rear I/O Differential Pair "J26_SIO5-"
XMC Site 2 Rear I/O Differential Pair "J26_SIO7+"
XMC Site 2 Rear I/O Differential Pair "J26_SIO7-"
XMC Site 2 Rear I/O Differential Pair "J26_SIO9+"
XMC Site 2 Rear I/O Differential Pair "J26_SIO9-"
XMC Site 2 Rear I/O Differential Pair "J26_SIO11+"
XMC Site 2 Rear I/O Differential Pair "J26_SIO11-"
XMC Site 2 Rear I/O Differential Pair "J26_SIO13+"
XMC Site 2 Rear I/O Differential Pair "J26_SIO13-"
XMC Site 2 Rear I/O Differential Pair "J26_SIO15+"
XMC Site 2 Rear I/O Differential Pair "J26_SIO15-"
XMC Site 2 Rear I/O Differential Pair "J26_SIO17+"
XMC Site 2 Rear I/O Differential Pair "J26_SIO17-"
5V Input Voltage
XMC Site 2 Rear I/O Differential Pair "J26_SIO0+"
XMC Site 2 Rear I/O Differential Pair "J26_SIO0-"
Ground
Ground
XMC Site 2 Rear I/O Differential Pair "J26_SIO2+"
XMC Site 2 Rear I/O Differential Pair "J26_SIO2-"
Ground
Ground
XMC Site 2 Rear I/O Differential Pair "J26_SIO6+"
XMC Site 2 Rear I/O Differential Pair "J26_SIO6-"
Ground
Ground
XMC Site 2 Rear I/O Differential Pair "J26_SIO10+"
XMC Site 2 Rear I/O Differential Pair "J26_SIO10-"
Ground
Ground
XMC Site 2 Rear I/O Differential Pair "J26_SIO14+"
XMC Site 2 Rear I/O Differential Pair "J26_SIO14-"
Acromag, Inc. Tel: 248-295-0310
- 17 -
D18
D19
D20
E1
E2
E3
E4
E5
E6
E7
E8
E9
E10
E11
E12
E13
E14
E15
E16
E17
E18
E19
E20
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
F11
F12
F13
F14
F15
F16
F17
F18
www.acromag.com
ACEX-FP-IO-0x User’s Manual
J26_SIO18_P
J26_SIO18_N
GND
GND
J26_DP17_N
J26_DP17_P
GND
GND
J26_DP13_N
J26_DP13_P
GND
GND
J26_DP09_N
J26_DP09_P
GND
GND
J26_DP05_N
J26_DP05_P
GND
GND
J26_DP01_N
J26_DP01_P
J26_DP19_N
J26_DP19_P
GND
GND
J26_DP15_N
J26_DP15_P
GND
GND
J26_DP11_N
J26_DP11_P
GND
GND
J26_DP07_N
J26_DP07_P
GND
GND
J26_DP03_N
J26_DP03_P
GND
COM Express Front Panel for Ruggedized/Military Packaging
XMC Site 2 Rear I/O Differential Pair "J26_SIO18+"
XMC Site 2 Rear I/O Differential Pair "J26_SIO18-"
Ground
Ground
XMC Site 2 Rear I/O Differential Pair "J26_DP17-"
XMC Site 2 Rear I/O Differential Pair "J26_DP17+"
Ground
Ground
XMC Site 2 Rear I/O Differential Pair "J26_DP13-"
XMC Site 2 Rear I/O Differential Pair "J26_DP13+"
Ground
Ground
XMC Site 2 Rear I/O Differential Pair "J26_DP09-"
XMC Site 2 Rear I/O Differential Pair "J26_DP09+"
Ground
Ground
XMC Site 2 Rear I/O Differential Pair "J26_DP05-"
XMC Site 2 Rear I/O Differential Pair "J26_DP05+"
Ground
Ground
XMC Site 2 Rear I/O Differential Pair "J26_DP01-"
XMC Site 2 Rear I/O Differential Pair "J26_DP01+"
XMC Site 2 Rear I/O Differential Pair "J26_DP19-"
XMC Site 2 Rear I/O Differential Pair "J26_DP19+"
Ground
Ground
XMC Site 2 Rear I/O Differential Pair "J26_DP15-"
XMC Site 2 Rear I/O Differential Pair "J26_DP15+"
Ground
Ground
XMC Site 2 Rear I/O Differential Pair "J26_DP11-"
XMC Site 2 Rear I/O Differential Pair "J26_DP11+"
Ground
Ground
XMC Site 2 Rear I/O Differential Pair "J26_DP07-"
XMC Site 2 Rear I/O Differential Pair "J26_DP07+"
Ground
Ground
XMC Site 2 Rear I/O Differential Pair "J26_DP03-"
XMC Site 2 Rear I/O Differential Pair "J26_DP03+"
Ground
Acromag, Inc. Tel: 248-295-0310
- 18 -
F19
F20
G1
G2
G3
G4
G5
G6
G7
G8
G9
G10
G11
G12
G13
G14
G15
G16
G17
G18
G19
G20
H1
H2
H3
H4
H5
H6
H7
H8
H9
H10
H11
H12
H13
H14
H15
H16
H17
H18
H19
www.acromag.com
ACEX-FP-IO-0x User’s Manual
GND
GND
GND
J26_DP16_N
J26_DP16_P
GND
GND
J26_DP12_N
J26_DP12_P
GND
GND
J26_DP08_N
J26_DP08_P
GND
GND
J26_DP04_N
J26_DP04_P
GND
GND
J26_DP00_N
J26_DP00_P
J26_DP18_N
J26_DP18_P
GND
GND
J26_DP14_N
J26_DP14_P
GND
GND
J26_DP10_N
J26_DP10_P
GND
GND
J26_DP06_N
J26_DP06_P
GND
GND
J26_DP02_N
J26_DP02_P
GND
GND
COM Express Front Panel for Ruggedized/Military Packaging
Ground
Ground
Ground
XMC Site 2 Rear I/O Differential Pair "J26_DP16-"
XMC Site 2 Rear I/O Differential Pair "J26_DP16+"
Ground
Ground
XMC Site 2 Rear I/O Differential Pair "J26_DP12-"
XMC Site 2 Rear I/O Differential Pair "J26_DP12+"
Ground
Ground
XMC Site 2 Rear I/O Differential Pair "J26_DP08-"
XMC Site 2 Rear I/O Differential Pair "J26_DP08+"
Ground
Ground
XMC Site 2 Rear I/O Differential Pair "J26_DP04-"
XMC Site 2 Rear I/O Differential Pair "J26_DP04+"
Ground
Ground
XMC Site 2 Rear I/O Differential Pair "J26_DP00-"
XMC Site 2 Rear I/O Differential Pair "J26_DP00+"
XMC Site 2 Rear I/O Differential Pair "J26_DP18-"
XMC Site 2 Rear I/O Differential Pair "J26_DP18+"
Ground
Ground
XMC Site 2 Rear I/O Differential Pair "J26_DP14-"
XMC Site 2 Rear I/O Differential Pair "J26_DP14+"
Ground
Ground
XMC Site 2 Rear I/O Differential Pair "J26_DP10-"
XMC Site 2 Rear I/O Differential Pair "J26_DP10+"
Ground
Ground
XMC Site 2 Rear I/O Differential Pair "J26_DP06-"
XMC Site 2 Rear I/O Differential Pair "J26_DP06+"
Ground
Ground
XMC Site 2 Rear I/O Differential Pair "J26_DP02-"
XMC Site 2 Rear I/O Differential Pair "J26_DP02+"
Ground
Ground
Acromag, Inc. Tel: 248-295-0310
- 19 -
H20
J1
J2
J3
J4
J5
J6
J7
J8
J9
J10
J11
J12
J13
J14
J15
J16
J17
J18
J19
J20
K1
K2
K3
K4
K5
K6
K7
K8
K9
K10
K11
K12
K13
K14
K15
K16
K17
K18
K19
K20
www.acromag.com
ACEX-FP-IO-0x User’s Manual
COM Express Front Panel for Ruggedized/Military Packaging
J2 (500 – Pin SEARAY Connector)
Signal Name
GND
J14_RIO19_N
J14_RIO19_P
J14_RIO24_P
J14_RIO24_N
J14_RIO20_N
J14_RIO20_P
J14_RIO21_N
J14_RIO21_P
J14_RIO23_P
J14_RIO23_N
J14_RIO25_P
J14_RIO25_N
J14_RIO27_P
J14_RIO27_N
J14_RIO29_P
J14_RIO29_N
J14_RIO31_P
J14_RIO31_N
VCC_12V_IN
USB0_+5V
FAN_TACH
FAN_PWM
PLT_RST#
USB3_+5V
EDP_HPD
EDP_BKLTCTL
EDP_BKLTEN
USB4_+5V
EXT_PWR_OUT
EXT_PWR_OUT
EXT_PWR_OUT
EXT_PWR_OUT
EXT_PWR_OUT
EXT_PWR_OUT
EXT_PWR_OUT
EXT_PWR_OUT
EXT_PWR_OUT
Description
Ground
PMC Site 1 Rear I/O Differential Pair "J14_RIO19-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO19+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO24+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO24-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO20-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO20+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO21-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO21+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO23+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO23-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO25+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO25-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO27+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO27-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO29+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO29-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO31+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO31-"
12V Input Voltage
USB0 Positive 5V from Carrier
CPU Fan TACH Input
CPU Fan Speed Control
Platform Reset Signal
USB3 Positive 5V from Carrier
eDP Hot Plug Detect
eDP Backlight Brightness Control
eDP Backlight Enable
USB4 Positive 5V from Carrier
External Output Power
External Output Power
External Output Power
External Output Power
External Output Power
External Output Power
External Output Power
External Output Power
External Output Power
Acromag, Inc. Tel: 248-295-0310
- 20 -
SEARAY Pin
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
A11
A12
A13
A14
A15
A16
A17
A18
A19
A20
A21
A22
A23
A24
A25
A26
A27
A28
A29
A30
A31
A32
A33
A34
A35
A36
A37
A38
www.acromag.com
ACEX-FP-IO-0x User’s Manual
EXT_PWR_OUT
VCC_5V_IN
GND
LINE-OUT_R
AUDIO_GND
LINE-IN_R
LINE-IN_L
GND
GBE0_MDI3_P
GBE0_MDI3_N
GBE1_MDI3_P
GBE1_MDI3_N
J14_RIO18_N
J14_RIO18_P
J14_RIO14_P
J14_RIO14_N
J14_RIO7_N
J14_RIO7_P
J14_RIO10_N
J14_RIO10_P
J14_RIO6_N
J14_RIO6_P
J14_RIO17_P
J14_RIO17_N
J14_RIO22_P
J14_RIO22_N
J14_RIO26_P
J14_RIO26_N
J14_RIO8_P
J14_RIO8_N
GPI_2
GPI_3
USB0_P
USB0_N
GPO_0
GPO_1
USB3_P
USB3_N
GND
GND
USB4_P
COM Express Front Panel for Ruggedized/Military Packaging
External Output Power
5V Input Voltage
Ground
Right Channel Audio Line Out from CODEC on Carrier
AUDIO_GND connected to Digital GND near CODEC on Carrier
Right Channel Audio Line In from CODEC on Carrier
Left Channel Audio Line In from CODEC on Carrier
Ground
Gigabit Ethernet Controller 0 from Module - MDI Differential Pair 3 Positive
Gigabit Ethernet Controller 0 from Module - MDI Differential Pair 3 Negative
Gigabit Ethernet Controller 1 from Carrier - MDI Differential Pair 3 Positive
Gigabit Ethernet Controller 1 from Carrier - MDI Differential Pair 3 Negative
PMC Site 1 Rear I/O Differential Pair "J14_RIO18-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO18+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO14+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO14-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO7-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO7+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO10-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO10+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO6-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO6+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO17+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO17-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO22+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO22-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO26+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO26-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO8+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO8-"
General Purpose Input 2
General Purpose Input 3
USB0 Differential Pair - "USB0+"
USB0 Differential Pair - "USB0-"
General Purpose Output 0
General Purpose Output 1
USB3 Differential Pair - "USB3+"
USB3 Differential Pair - "USB3-"
Ground
Ground
USB4 Differential Pair - "USB4+"
Acromag, Inc. Tel: 248-295-0310
- 21 -
A39
A40
A41
A42
A43
A44
A45
A46
A47
A48
A49
A50
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11
B12
B13
B14
B15
B16
B17
B18
B19
B20
B21
B22
B23
B24
B25
B26
B27
B28
B29
www.acromag.com
ACEX-FP-IO-0x User’s Manual
USB4_N
USB5_+5V
DPC_AUX_SEL
UART_TX0_P
UART_TX0_N
UART_RX0_P
UART_RX0_N
UART_TX1_P
UART_TX1_N
UART_RX1_P
UART_RX1_N
VCC_3.3V_IN
LINE-OUT_L
VGA_BLU
VGA_RED
VGA_GRN
GND
GBE0_MDI2_P
GBE0_MDI2_N
GBE1_MDI2_P
GBE1_MDI2_N
WDTO
J14_RIO13_N
J14_RIO13_P
J14_RIO9_N
J14_RIO9_P
J14_RIO5_N
J14_RIO5_P
J14_RIO1_N
J14_RIO1_P
J14_RIO2_N
J14_RIO2_P
J14_RIO28_P
J14_RIO28_N
J14_RIO12_N
J14_RIO12_P
J14_RIO4_P
J14_RIO4_N
J14_RIO30_P
J14_RIO30_N
GPI_1
COM Express Front Panel for Ruggedized/Military Packaging
USB4 Differential Pair - "USB4-"
USB5 Positive 5V from Carrier
Digital Display Interface 2 - AUX Function Select
General Purpose Serial Port 0 from Carrier Transmitter Positive
General Purpose Serial Port 0 from Carrier Transmitter Negative
General Purpose Serial Port 0 from Carrier Receiver Positive
General Purpose Serial Port 0 from Carrier Receiver Negative
General Purpose Serial Port 1 from Carrier Transmitter Positive
General Purpose Serial Port 1 from Carrier Transmitter Negative
General Purpose Serial Port 1 from Carrier Receiver Positive
General Purpose Serial Port 1 from Carrier Receiver Negative
3.3V Input Voltage
Left Channel Audio Line Out from CODEC on Carrier
Analog Video Output Blue
Analog Video Output Red
Analog Video Output Green
Ground
Gigabit Ethernet Controller 0 from Module - MDI Differential Pair 2 Positive
Gigabit Ethernet Controller 0 from Module - MDI Differential Pair 2 Negative
Gigabit Ethernet Controller 1 from Carrier - MDI Differential Pair 2 Positive
Gigabit Ethernet Controller 1 from Carrier - MDI Differential Pair 2 Negative
Watchdog Timer Output
PMC Site 1 Rear I/O Differential Pair "J14_RIO13-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO13+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO9-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO9+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO5-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO5+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO1-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO1+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO2-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO2+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO28+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO28-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO12-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO12+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO4+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO4-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO30+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO30-"
General Purpose Input 1
Acromag, Inc. Tel: 248-295-0310
- 22 -
B30
B31
B32
B33
B34
B35
B36
B37
B38
B39
B40
B41
B42
B43
B44
B45
B46
B47
B48
B49
B50
C1
C2
C3
C4
C5
C6
C7
C8
C9
C10
C11
C12
C13
C14
C15
C16
C17
C18
C19
C20
www.acromag.com
ACEX-FP-IO-0x User’s Manual
USB1_+5V
EDP_VDDEN
EDP_TX3_N
EDP_TX3_P
GND
GND
DPC_TX3_N
DPC_TX3_P
GND
GND
USB5_P
USB5_N
DPC_HPD
THRMTRIP3#
SPKR
BATLOW#
SUS_STAT#
VCC_5V_IN
VCC_5V_IN
SATA_ACT#
VCC_3.3V_IN
GND
GND
GND
GND
VGA_I2C_DAT
GBE0_MDI1_P
GBE0_MDI1_N
GBE1_MDI1_P
GBE1_MDI1_N
J14_RIO15_N
J14_RIO15_P
J14_RIO11_N
J14_RIO11_P
J16_SIO1_N
J16_SIO1_P
J14_RIO3_N
J14_RIO3_P
J16_SIO8_P
J16_SIO8_N
J14_RIO16_N
COM Express Front Panel for Ruggedized/Military Packaging
USB1 Positive 5V from Carrier
eDP Power Enable
eDP Differential Pair 3 Negative
eDP Differential Pair 3 Positive
Ground
Ground
Digital Display Interface 2 - Output Differential Pair 3 Negative
Digital Display Interface 2 - Output Differential Pair 3 Positive
Ground
Ground
USB5 Differential Pair - "USB5+"
USB5 Differential Pair - "USB5-"
Digital Display Interface 2 - Hot Plug Detect
Output Signal Indicating CPU Entered Thermal Shutdown
Audio Enunciator Output - PC Beep Signal
Low Battery Indicator for External Battery
Imminent Suspend Operation Indicator - Notifies LPC Devices
5V Input Voltage
5V Input Voltage
ATA (Parallel and Serial) or SAS Activity Indicator Signal
3.3V Input Voltage
Ground
Ground
Ground
Ground
Display Data Channel (DDC) Data Line
Gigabit Ethernet Controller 0 from Module - MDI Differential Pair 1 Positive
Gigabit Ethernet Controller 0 from Module - MDI Differential Pair 1 Negative
Gigabit Ethernet Controller 1 from Carrier - MDI Differential Pair 1 Positive
Gigabit Ethernet Controller 1 from Carrier - MDI Differential Pair 1 Negative
PMC Site 1 Rear I/O Differential Pair "J14_RIO15-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO15+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO11-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO11+"
XMC Site 1 Rear I/O Differential Pair "J16_SIO1-"
XMC Site 1 Rear I/O Differential Pair "J16_SIO1+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO3-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO3+"
XMC Site 1 Rear I/O Differential Pair "J16_SIO8+"
XMC Site 1 Rear I/O Differential Pair "J16_SIO8-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO16-"
Acromag, Inc. Tel: 248-295-0310
- 23 -
C21
C22
C23
C24
C25
C26
C27
C28
C29
C30
C31
C32
C33
C34
C35
C36
C37
C38
C39
C40
C41
C42
C43
C44
C45
C46
C47
C48
C49
C50
D1
D2
D3
D4
D5
D6
D7
D8
D9
D10
D11
www.acromag.com
ACEX-FP-IO-0x User’s Manual
J14_RIO16_P
J16_SIO12_P
J16_SIO12_N
J14_RIO0_N
J14_RIO0_P
J16_SIO16_P
J16_SIO16_N
GPI_0
GPO_3
USB1_P
USB1_N
GND
GND
EDP_TX1_N
EDP_TX1_P
GND
GND
DPC_TX0_N
DPC_TX0_P
GND
GND
DPD_AUX_SEL
DPD_HPD
COM_THRM#
DPB_AUX_SEL
DPB_HPD
SLP_S5#
SLP_S4#
SLP_S3#
LPC_DRQ1#
LPC_DRQ0#
VCC_3.3V_IN
VGA_VSYNC
VGA_HSYNC
VGA_I2C_CK
GBE0_MDI0_P
GBE0_MDI0_N
GBE1_MDI0_P
GBE1_MDI0_N
SYSRST#
J16_SIO2_N
COM Express Front Panel for Ruggedized/Military Packaging
PMC Site 1 Rear I/O Differential Pair "J14_RIO16+"
XMC Site 1 Rear I/O Differential Pair "J16_SIO12+"
XMC Site 1 Rear I/O Differential Pair "J16_SIO12-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO0-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO0+"
XMC Site 1 Rear I/O Differential Pair "J16_SIO16+"
XMC Site 1 Rear I/O Differential Pair "J16_SIO16-"
General Purpose Input 0
General Purpose Output 3
USB1 Differential Pair - "USB1+"
USB1 Differential Pair - "USB1-"
Ground
Ground
eDP Differential Pair 1 Negative
eDP Differential Pair 1 Positive
Ground
Ground
Digital Display Interface 2 - Output Differential Pair 0 Negative
Digital Display Interface 2 - Output Differential Pair 0 Positive
Ground
Ground
Digital Display Interface 3 - AUX Function Select
Digital Display Interface 3 - Hot Plug Detect
Off-Module Temp Sensor Input Signal Indicating Over-Temp Condition
Digital Display Interface 1 - AUX Function Select
Digital Display Interface 1 - Hot Plug Detect
Output Signal Indicating Soft Off State
Output Signal Indicating Suspend to Disk State
Output Signal Indicating Suspend to RAM State
LPC Serial DMA Request Signal 1
LPC Serial DMA Request Signal 0
3.3V Input Voltage
VGA Output Vertical Sync
VGA Output Horizontal Sync
Display Data Channel (DDC) Clock Line
Gigabit Ethernet Controller 0 from Module - MDI Differential Pair 0 Positive
Gigabit Ethernet Controller 0 from Module - MDI Differential Pair 0 Negative
Gigabit Ethernet Controller 1 from Carrier - MDI Differential Pair 0 Positive
Gigabit Ethernet Controller 1 from Carrier - MDI Differential Pair 0 Negative
System Reset Signal
XMC Site 1 Rear I/O Differential Pair "J16_SIO2-"
Acromag, Inc. Tel: 248-295-0310
- 24 -
D12
D13
D14
D15
D16
D17
D18
D19
D20
D21
D22
D23
D24
D25
D26
D27
D28
D29
D30
D31
D32
D33
D34
D35
D36
D37
D38
D39
D40
D41
D42
D43
D44
D45
D46
D47
D48
D49
D50
E1
E2
www.acromag.com
ACEX-FP-IO-0x User’s Manual
J16_SIO2_P
J16_SIO3_P
J16_SIO3_N
J16_DP16_N
J16_DP16_P
J16_DP19_P
J16_DP19_N
J16_SIO9_P
J16_SIO9_N
J16_SIO0_GCLK_P
J16_SIO0_GCLK_N
J16_SIO13_P
J16_SIO13_N
J16_SIO15_P
J16_SIO15_N
J16_SIO17_P
J16_SIO17_N
GPO_2
USB2_+5V
GND
EDP_TX0_N
EDP_TX0_P
GND
GND
DPC_TX2_N
DPC_TX2_P
GND
GND
DPC_CTRL_AUX_N
DPC_CTRL_AUX_P
GND
GND
I2C_DAT
I2C_CLK
GND
GND
SMB_DATA
SMB_CLK
SMB_ALERT#
LPC_SERIRQ
LPC_FRAME#
COM Express Front Panel for Ruggedized/Military Packaging
XMC Site 1 Rear I/O Differential Pair "J16_SIO2+"
XMC Site 1 Rear I/O Differential Pair "J16_SIO3+"
XMC Site 1 Rear I/O Differential Pair "J16_SIO3-"
XMC Site 1 Rear I/O Differential Pair "J16_DP16-"
XMC Site 1 Rear I/O Differential Pair "J16_DP16+"
XMC Site 1 Rear I/O Differential Pair "J16_DP19+"
XMC Site 1 Rear I/O Differential Pair "J16_DP19-"
XMC Site 1 Rear I/O Differential Pair "J16_SIO9+"
XMC Site 1 Rear I/O Differential Pair "J16_SIO9-"
XMC Site 1 Rear I/O Differential Pair "J16_SIO0+"
XMC Site 1 Rear I/O Differential Pair "J16_SIO0-"
XMC Site 1 Rear I/O Differential Pair "J16_SIO13+"
XMC Site 1 Rear I/O Differential Pair "J16_SIO13-"
XMC Site 1 Rear I/O Differential Pair "J16_SIO15+"
XMC Site 1 Rear I/O Differential Pair "J16_SIO15-"
XMC Site 1 Rear I/O Differential Pair "J16_SIO17+"
XMC Site 1 Rear I/O Differential Pair "J16_SIO17-"
General Purpose Output 2
USB2 Positive 5V from Carrier
Ground
eDP Differential Pair 0 Negative
eDP Differential Pair 0 Positive
Ground
Ground
Differential Pair - "DDI2_PAIR2-"
Differential Pair - "DDI2_PAIR2+"
Ground
Ground
Digital Display Interface 2 - DVI/HDMI/DP AUX Control Negative
Digital Display Interface 2 - DVI/HDMI/DP AUX Control Positive
Ground
Ground
General Purpose I2C Port Data I/O Line
General Purpose I2C Port Clock Output
Ground
Ground
System Management Bus Bidirectional Data Line
System Management Bus Bidirectional Clock Line
System Management Bus Alert Signal
LPC Serial Interrupt Signal
LPC Frame Signal - LPC Cycle Start Indicator
Acromag, Inc. Tel: 248-295-0310
- 25 -
E3
E4
E5
E6
E7
E8
E9
E10
E11
E12
E13
E14
E15
E16
E17
E18
E19
E20
E21
E22
E23
E24
E25
E26
E27
E28
E29
E30
E31
E32
E33
E34
E35
E36
E37
E38
E39
E40
E41
E42
E43
www.acromag.com
ACEX-FP-IO-0x User’s Manual
VCC_3.3V_IN
LPC_AD1
LPC_AD0
GBE0_L1000#
GBE1_1V9
GBE0_LINK#
GBE1_LINK#
J16_DP17_N
J16_DP17_P
GND
GND
J16_DP11_N
J16_DP11_P
GND
GND
J16_DP07_N
J16_DP07_P
GND
GND
J16_SIO10_P
J16_SIO10_N
GND
GND
J16_DP02_N
J16_DP02_P
J16_DP00_N
J16_DP00_P
USB2_P
USB2_N
GND
GND
EDP_TX2_N
EDP_TX2_P
GND
GND
DPC_TX1_N
DPC_TX1_P
GND
GND
DPD_CTRL_AUX_N
DPD_CTRL_AUX_P
COM Express Front Panel for Ruggedized/Military Packaging
3.3V Input Voltage
LPC Multiplexed Address - Command and Data Bus 1
LPC Multiplexed Address - Command and Data Bus 0
Gigabit Ethernet Controller 0 from Module - 1000 Mb/s Link Indicator
External 1.9V Reference Voltage from Carrier for Gigabit Ethernet Controller 1
Gigabit Ethernet Controller 0 from Module - Link Indicator
Gigabit Ethernet Controller 1 from Carrier - Link Indicator
XMC Site 1 Rear I/O Differential Pair "J16_DP17-"
XMC Site 1 Rear I/O Differential Pair "J16_DP17+"
Ground
Ground
XMC Site 1 Rear I/O Differential Pair "J16_DP11-"
XMC Site 1 Rear I/O Differential Pair "J16_DP11+"
Ground
Ground
XMC Site 1 Rear I/O Differential Pair "J16_DP07-"
XMC Site 1 Rear I/O Differential Pair "J16_DP07+"
Ground
Ground
XMC Site 1 Rear I/O Differential Pair "J16_SIO10+"
XMC Site 1 Rear I/O Differential Pair "J16_SIO10-"
Ground
Ground
XMC Site 1 Rear I/O Differential Pair "J16_DP02-"
XMC Site 1 Rear I/O Differential Pair "J16_DP02+"
XMC Site 1 Rear I/O Differential Pair "J16_DP00-"
XMC Site 1 Rear I/O Differential Pair "J16_DP00+"
USB2 Differential Pair - "USB2+"
USB2 Differential Pair - "USB2-"
Ground
Ground
eDP Differential Pair 2 Negative
eDP Differential Pair 2 Positive
Ground
Ground
Digital Display Interface 2 - Output Differential Pair 1 Negative
Digital Display Interface 2 - Output Differential Pair 1 Positive
Ground
Ground
Digital Display Interface 3 - DVI/HDMI/DP AUX Control Negative
Digital Display Interface 3 - DVI/HDMI/DP AUX Control Positive
Acromag, Inc. Tel: 248-295-0310
- 26 -
E44
E45
E46
E47
E48
E49
E50
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
F11
F12
F13
F14
F15
F16
F17
F18
F19
F20
F21
F22
F23
F24
F25
F26
F27
F28
F29
F30
F31
F32
F33
F34
www.acromag.com
ACEX-FP-IO-0x User’s Manual
GND
GND
DPB_CTRL_AUX_N
DPB_CTRL_AUX_P
GND
GND
PWRBTN#
LPC_CLK
GND
GND
LPC_AD3
LPC_AD2
GND
GND
GBE0_ACT#
GBE1_ACT#
GND
GND
J16_SIO5_P
J16_SIO5_N
GND
GND
J16_DP08_N
J16_DP08_P
GND
GND
J16_DP09_N
J16_DP09_P
GND
GND
J16_DP05_N
J16_DP05_P
GND
GND
J16_DP01_N
J16_DP01_P
WAKE1#
WAKE0#
PCIE0_RX_N
PCIE0_RX_P
GND
COM Express Front Panel for Ruggedized/Military Packaging
Ground
Ground
Digital Display Interface 1 - DVI/HDMI/DP AUX Control Negative
Digital Display Interface 1 - DVI/HDMI/DP AUX Control Positive
Ground
Ground
Power Button Input Signal
LPC Clock Output - 33MHz Nominal
Ground
Ground
LPC Multiplexed Address - Command and Data Bus 3
LPC Multiplexed Address - Command and Data Bus 2
Ground
Ground
Gigabit Ethernet Controller 0 from Module - Activity Indicator
Gigabit Ethernet Controller 1 from Carrier - Activity Indicator
Ground
Ground
XMC Site 1 Rear I/O Differential Pair "J16_SIO5+"
XMC Site 1 Rear I/O Differential Pair "J16_SIO5-"
Ground
Ground
XMC Site 1 Rear I/O Differential Pair "J16_DP08-"
XMC Site 1 Rear I/O Differential Pair "J16_DP08+"
Ground
Ground
XMC Site 1 Rear I/O Differential Pair "J16_DP09-"
XMC Site 1 Rear I/O Differential Pair "J16_DP09+"
Ground
Ground
XMC Site 1 Rear I/O Differential Pair "J16_DP05-"
XMC Site 1 Rear I/O Differential Pair "J16_DP05+"
Ground
Ground
XMC Site 1 Rear I/O Differential Pair "J16_DP01-"
XMC Site 1 Rear I/O Differential Pair "J16_DP01+"
General Purpose Wake Signal
PCI Express Wake Signal
PCI Express Lane 0 Receive Differential Pair Negative
PCI Express Lane 0 Receive Differential Pair Positive
Ground
Acromag, Inc. Tel: 248-295-0310
- 27 -
F35
F36
F37
F38
F39
F40
F41
F42
F43
F44
F45
F46
F47
F48
F49
F50
G1
G2
G3
G4
G5
G6
G7
G8
G9
G10
G11
G12
G13
G14
G15
G16
G17
G18
G19
G20
G21
G22
G23
G24
G25
www.acromag.com
ACEX-FP-IO-0x User’s Manual
GND
PCIE2_RX_N
PCIE2_RX_P
GND
GND
DPD_TX3_N
DPD_TX3_P
GND
GND
DPB_TX3_N
DPB_TX3_P
GND
GND
SATA1_RX_N
SATA1_RX_P
GND
GND
USB3_SSRX_P
USB3_SSRX_N
GND
GND
USB1_SSRX_P
USB1_SSRX_N
GND
GND
J16_DP15_N
J16_DP15_P
GND
GND
J16_DP13_N
J16_DP13_P
GND
GND
J16_SIO11_P
J16_SIO11_N
GND
GND
J16_DP04_N
J16_DP04_P
GND
GND
COM Express Front Panel for Ruggedized/Military Packaging
Ground
PCI Express Lane 2 Receive Differential Pair Negative
PCI Express Lane 2 Receive Differential Pair Positive
Ground
Ground
Digital Display Interface 3 - Output Differential Pair 3 Negative
Digital Display Interface 3 - Output Differential Pair 3 Positive
Ground
Ground
Digital Display Interface 1 - Output Differential Pair 3 Negative
Digital Display Interface 1 - Output Differential Pair 3 Positive
Ground
Ground
SATA1 Receive Differential Pair Negative
SATA1 Receive Differential Pair Positive
Ground
Ground
USB3 USB 3.0 SuperSpeed Receive Positive
USB3 USB 3.0 SuperSpeed Receive Negative
Ground
Ground
USB1 USB 3.0 SuperSpeed Receive Positive
USB1 USB 3.0 SuperSpeed Receive Negative
Ground
Ground
XMC Site 1 Rear I/O Differential Pair "J16_DP15-"
XMC Site 1 Rear I/O Differential Pair "J16_DP15+"
Ground
Ground
XMC Site 1 Rear I/O Differential Pair "J16_DP13-"
XMC Site 1 Rear I/O Differential Pair "J16_DP13+"
Ground
Ground
XMC Site 1 Rear I/O Differential Pair "J16_SIO11+"
XMC Site 1 Rear I/O Differential Pair "J16_SIO11-"
Ground
Ground
XMC Site 1 Rear I/O Differential Pair "J16_DP04-"
XMC Site 1 Rear I/O Differential Pair "J16_DP04+"
Ground
Ground
Acromag, Inc. Tel: 248-295-0310
- 28 -
G26
G27
G28
G29
G30
G31
G32
G33
G34
G35
G36
G37
G38
G39
G40
G41
G42
G43
G44
G45
G46
G47
G48
G49
G50
H1
H2
H3
H4
H5
H6
H7
H8
H9
H10
H11
H12
H13
H14
H15
H16
www.acromag.com
ACEX-FP-IO-0x User’s Manual
J16_SIO6_N
J16_SIO6_P
GND
GND
EDP_AUX_N
EDP_AUX_P
GND
GND
PCIE0_TX_N
PCIE0_TX_P
GND
GND
PCIE2_TX_N
PCIE2_TX_P
GND
GND
DPD_TX0_N
DPD_TX0_P
GND
GND
DPB_TX0_N
DPB_TX0_P
GND
GND
SATA1_TX_N
SATA1_TX_P
GND
GND
USB3_SSTX_P
USB3_SSTX_N
GND
GND
USB1_SSTX_P
USB1_SSTX_N
GND
GND
J16_SIO7_P
J16_SIO7_N
GND
GND
J16_SIO4_P
COM Express Front Panel for Ruggedized/Military Packaging
XMC Site 1 Rear I/O Differential Pair "J16_SIO6-"
XMC Site 1 Rear I/O Differential Pair "J16_SIO6+"
Ground
Ground
eDP AUX Signal Negative
eDP AUX Signal Positive
Ground
Ground
PCI Express Lane 0 Transmit Differential Pair Negative
PCI Express Lane 0 Transmit Differential Pair Positive
Ground
Ground
PCI Express Lane 2 Transmit Differential Pair Negative
PCI Express Lane 2 Transmit Differential Pair Positive
Ground
Ground
Digital Display Interface 3 - Output Differential Pair 0 Negative
Digital Display Interface 3 - Output Differential Pair 0 Positive
Ground
Ground
Digital Display Interface 1 - Output Differential Pair 0 Negative
Digital Display Interface 1 - Output Differential Pair 0 Positive
Ground
Ground
SATA1 Transmit Differential Pair Negative
SATA1 Transmit Differential Pair Positive
Ground
Ground
USB3 USB 3.0 SuperSpeed Transmit Positive
USB3 USB 3.0 SuperSpeed Transmit Negative
Ground
Ground
USB1 USB 3.0 SuperSpeed Transmit Positive
USB1 USB 3.0 SuperSpeed Transmit Negative
Ground
Ground
XMC Site 1 Rear I/O Differential Pair "J16_SIO7+"
XMC Site 1 Rear I/O Differential Pair "J16_SIO7-"
Ground
Ground
XMC Site 1 Rear I/O Differential Pair "J16_SIO4+"
Acromag, Inc. Tel: 248-295-0310
- 29 -
H17
H18
H19
H20
H21
H22
H23
H24
H25
H26
H27
H28
H29
H30
H31
H32
H33
H34
H35
H36
H37
H38
H39
H40
H41
H42
H43
H44
H45
H46
H47
H48
H49
H50
J1
J2
J3
J4
J5
J6
J7
www.acromag.com
ACEX-FP-IO-0x User’s Manual
J16_SIO4_N
GND
GND
J16_DP06_N
J16_DP06_P
GND
GND
J16_DP03_N
J16_DP03_P
GND
GND
J16_DP12_N
J16_DP12_P
GND
GND
PCIE1_RX_N
PCIE1_RX_P
GND
GND
PCIE3_RX_N
PCIE3_RX_P
GND
GND
DPD_TX2_N
DPD_TX2_P
GND
GND
DPB_TX2_N
DPB_TX2_P
GND
GND
SATA0_RX_N
SATA0_RX_P
GND
GND
USB2_SSRX_P
USB2_SSRX_N
GND
GND
USB0_SSRX_P
USB0_SSRX_N
COM Express Front Panel for Ruggedized/Military Packaging
XMC Site 1 Rear I/O Differential Pair "J16_SIO4-"
Ground
Ground
XMC Site 1 Rear I/O Differential Pair "J16_DP06-"
XMC Site 1 Rear I/O Differential Pair "J16_DP06+"
Ground
Ground
XMC Site 1 Rear I/O Differential Pair "J16_DP03-"
XMC Site 1 Rear I/O Differential Pair "J16_DP03+"
Ground
Ground
XMC Site 1 Rear I/O Differential Pair "J16_DP12-"
XMC Site 1 Rear I/O Differential Pair "J16_DP12+"
Ground
Ground
PCI Express Lane 1 Receive Differential Pair Negative
PCI Express Lane 1 Receive Differential Pair Positive
Ground
Ground
PCI Express Lane 3 Receive Differential Pair Negative
PCI Express Lane 3 Receive Differential Pair Positive
Ground
Ground
Digital Display Interface 3 - Output Differential Pair 2 Negative
Digital Display Interface 3 - Output Differential Pair 2 Positive
Ground
Ground
Digital Display Interface 1 - Output Differential Pair 2 Negative
Digital Display Interface 1 - Output Differential Pair 2 Positive
Ground
Ground
SATA0 Receive Differential Pair Negative
SATA0 Receive Differential Pair Positive
Ground
Ground
USB2 USB 3.0 SuperSpeed Receive Positive
USB2 USB 3.0 SuperSpeed Receive Negative
Ground
Ground
USB0 USB 3.0 SuperSpeed Receive Positive
USB0 USB 3.0 SuperSpeed Receive Negative
Acromag, Inc. Tel: 248-295-0310
- 30 -
J8
J9
J10
J11
J12
J13
J14
J15
J16
J17
J18
J19
J20
J21
J22
J23
J24
J25
J26
J27
J28
J29
J30
J31
J32
J33
J35
J35
J36
J37
J38
J39
J40
J41
J42
J43
J44
J45
J46
J47
J48
www.acromag.com
ACEX-FP-IO-0x User’s Manual
GND
GND
J16_DP18_N
J16_DP18_P
GND
GND
J16_DP14_N
J16_DP14_P
GND
GND
J16_DP10_N
J16_DP10_P
GND
GND
J16_SIO14_P
J16_SIO14_N
GND
GND
J16_SIO18_GCLK_P
J16_SIO18_GCLK_N
GND
GND
CLK_PEG_N
CLK_PEG_P
GND
GND
PCIE1_TX_P
PCIE1_TX_N
GND
GND
PCIE3_TX_N
PCIE3_TX_P
GND
GND
DPD_TX1_N
DPD_TX1_P
GND
GND
DPB_TX1_N
DPB_TX1_P
GND
COM Express Front Panel for Ruggedized/Military Packaging
Ground
Ground
XMC Site 1 Rear I/O Differential Pair "J16_DP18-"
XMC Site 1 Rear I/O Differential Pair "J16_DP18+"
Ground
Ground
XMC Site 1 Rear I/O Differential Pair "J16_DP14-"
XMC Site 1 Rear I/O Differential Pair "J16_DP14+"
Ground
Ground
XMC Site 1 Rear I/O Differential Pair "J16_DP10-"
XMC Site 1 Rear I/O Differential Pair "J16_DP10+"
Ground
Ground
XMC Site 1 Rear I/O Differential Pair "J16_SIO14+"
XMC Site 1 Rear I/O Differential Pair "J16_SIO14-"
Ground
Ground
XMC Site 1 Rear I/O Differential Pair "J16_SIO18+"
XMC Site 1 Rear I/O Differential Pair "J16_SIO18-"
Ground
Ground
PCIe/PEG Reference Clock Output Negative
PCIe/PEG Reference Clock Output Positive
Ground
Ground
PCI Express Lane 1 Transmit Differential Pair Positive
PCI Express Lane 1 Transmit Differential Pair Negative
Ground
Ground
PCI Express Lane 3 Transmit Differential Pair Negative
PCI Express Lane 3 Transmit Differential Pair Positive
Ground
Ground
Digital Display Interface 3 - Output Differential Pair 1 Negative
Digital Display Interface 3 - Output Differential Pair 1 Positive
Ground
Ground
Digital Display Interface 1 - Output Differential Pair 1 Negative
Digital Display Interface 1 - Output Differential Pair 1 Positive
Ground
Acromag, Inc. Tel: 248-295-0310
- 31 -
J49
J50
K1
K2
K3
K4
K5
K6
K7
K8
K9
K10
K11
K12
K13
K14
K15
K16
K17
K18
K19
K20
K21
K22
K23
K24
K25
K26
K27
K28
K29
K30
K31
K32
K33
K34
K35
K36
K37
K38
K39
www.acromag.com
ACEX-FP-IO-0x User’s Manual
GND
SATA0_TX_N
SATA0_TX_P
GND
GND
USB2_SSTX_P
USB2_SSTX_N
GND
GND
USB0_SSTX_P
USB0_SSTX_N
COM Express Front Panel for Ruggedized/Military Packaging
Ground
SATA0 Transmit Differential Pair Negative
SATA0 Transmit Differential Pair Positive
Ground
Ground
USB2 USB 3.0 SuperSpeed Transmit Positive
USB2 USB 3.0 SuperSpeed Transmit Negative
Ground
Ground
USB0 USB 3.0 SuperSpeed Transmit Positive
USB0 USB 3.0 SuperSpeed Transmit Negative
Acromag, Inc. Tel: 248-295-0310
- 32 -
K40
K41
K42
K43
K44
K45
K46
K47
K48
K49
K50
www.acromag.com
ACEX-FP-IO-0x User’s Manual
COM Express Front Panel for Ruggedized/Military Packaging
J3 – Keyed-A (130-Pin size #23 38999 Connector)
PMC/XMC rear I/O from PMC/XMC Site 1 on the carrier (ACEX-46xx)
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
Signal Name
J14_RIO0_P
J14_RIO0_N
J14_RIO1_P
J14_RIO1_N
J14_RIO2_P
J14_RIO2_N
J14_RIO3_P
J14_RIO3_N
GND
J14_RIO4_P
J14_RIO4_N
GND
J14_RIO5_P
J14_RIO5_N
GND
J14_RIO6_P
J14_RIO6_N
J14_RIO7_P
J14_RIO7_N
J14_RIO8_P
J14_RIO8_N
J14_RIO9_P
J14_RIO9_N
J14_RIO10_P
J14_RIO10_N
GND
J14_RIO11_P
J14_RIO11_N
J14_RIO12_P
J14_RIO12_N
No Connect
J14_RIO13_P
J14_RIO13_N
Pin
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
Acromag, Inc. Tel: 248-295-0310
Signal Name
J14_RIO14_P
J14_RIO14_N
GND
J14_RIO15_P
J14_RIO15_N
GND
GND
J14_RIO16_P
J14_RIO16_N
J14_RIO17_P
J14_RIO17_N
GND
GND
J14_RIO18_P
J14_RIO18_N
GND
J14_RIO19_P
J14_RIO19_N
J14_RIO20_P
J14_RIO20_N
GND
J14_RIO21_P
J14_RIO21_N
J14_RIO22_P
J14_RIO22_N
GND
J14_RIO23_P
J14_RIO23_N
J14_RIO24_P
J14_RIO24_N
GND
J14_RIO25_P
J14_RIO25_N
Pin
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
Signal Name
J14_RIO26_P
J14_RIO26_N
GND
J14_RIO27_P
J14_RIO27_N
J14_RIO28_P
J14_RIO28_N
GND
J14_RIO29_P
J14_RIO29_N
GND
J14_RIO30_P
J14_RIO30_N
GND
J14_RIO31_P
J14_RIO31_N
GND
J16_SIO0_GCLK_P
J16_SIO0_GCLK_N
J16_SIO1_P
J16_SIO1_N
J16_SIO2_P
J16_SIO2_N
J16_SIO3_P
J16_SIO3_N
J16_SIO4_P
J16_SIO4_N
GND
J16_SIO5_P
J16_SIO5_N
GND
J16_SIO6_P
J16_SIO6_N
- 33 -
Pin
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
Signal Name
GND
J16_SIO7_P
J16_SIO7_N
J16_SIO8_P
J16_SIO8_N
GND
J16_SIO9_P
J16_SIO9_N
J16_SIO10_P
J16_SIO10_N
No Connect
J16_SIO11_P
J16_SIO11_N
GND
J16_SIO12_P
J16_SIO12_N
GND
J16_SIO13_P
J16_SIO13_N
GND
J16_SIO14_P
J16_SIO14_N
GND
J16_SIO15_P
J16_SIO15_N
J16_SIO16_P
J16_SIO16_N
J16_SIO17_P
J16_SIO17_N
J16_SIO18_GCLK_P
J16_SIO18_GCLK_N
www.acromag.com
ACEX-FP-IO-0x User’s Manual
COM Express Front Panel for Ruggedized/Military Packaging
J4 – Keyed-B (130-Pin size #23 38999 Connector)
Standard Peripheral I/O Signals
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
Signal Name
DPB_DDC_CLOCK
DPB_DDC_DATA
USB0_N
USB0_P
DPC_DDC_CLOCK
DPC_DDC_DATA
DPB_TMDS_D1_SHIELD
DPB_TMDS_D0_P
DPB_TMDS_D0_N
USB0_+5V
USB0_GND
USB1_GND
DPC_TMDS_D0_P
DPC_TMDS_D0_N
DPC_TMDS_D0_SHIELD
DPB_TMDS_D1_P
DPB_TMDS_D1_N
DPB_TMDS_D0_SHIELD
GND
GND
USB1_N
USB1_P
DPC_TMDS_D1_SHIELD
DPC_TMDS_D1_P
DPC_TMDS_D1_N
DPB_TMDS_D2_P
DPB_TMDS_D2_N
DPB_TMDS_CLOCK_SHIELD
DPB_TMDS_PWR
USB2_N
USB2_P
USB1_+5V
DPC_TMDS_PWR
Acromag, Inc. Tel: 248-295-0310
Pin
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
Signal Name
DPC_TMDS_CLOCK_SHIELD
DPC_TMDS_D2_P
DPC_TMDS_D2_N
DPB_HPD
DPB_TMDS_D2_SHIELD
DPB_TMDS_CLK_P
DPB_TMDS_CLK_N
GND
USB2_GND
USB2_+5V
GND
DPC_TMDS_CLK_P
DPC_TMDS_CLK_N
DPC_TMDS_D2_SHIELD
DPC_HPD
No Connect
No Connect
No Connect
No Connect
No Connect
No Connect
No Connect
No Connect
GND
GND
+12V (SATA)
LAN0 DI0 P
LAN0 DI1 P
LAN0 DI2 P
LAN0 DI3 P
LAN1 DI0 P
LAN1 DI1 P
LAN1 DI2 P
- 34 -
Pin
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
Signal Name
LAN1 DI3 P
GND
GND
+12V (SATA)
+5V (SATA)
LAN0 DI0 N
LAN0 DI1 N
LAN0 DI2 N
LAN0 DI3 N
LAN1 DI0 N
LAN1 DI1 N
LAN1 DI2 N
LAN1 DI3 N
UART_RX1_P
GND
+5V (SATA)
GND
VGA GND
GND
SATA0_TX_P
SATA0_TX_N
GND
GND
GND
UART_TX1_P
UART_RX1_N
+5V (SATA)
+3.3V (SATA)
VGA BLUE
VGA GND
SATA0_RX_N
SATA0_RX_P
GND
Pin
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
Signal Name
WDTO
GND
GND
UART_TX1_N
GND
+3.3V (SATA)
VGA RED
VGA GND
GND
GND
GND
UART_RX0_P
LINE IN R
AUDIO GND
LINE OUT R
+3.3V (SATA)
VGA GREEN
VGA PWR
(1.5AHSYNC
–FUSED)
VGA
VGA VSYNC
UART_TX0_P
UART_RX0_N
LINE IN L
LINE OUT L
AUDIO GND
VGA SDATA
VGA SCLOCK
GND
UART_TX0_N
GND
No Connect
www.acromag.com
ACEX-FP-IO-0x User’s Manual
COM Express Front Panel for Ruggedized/Military Packaging
J5 – Keyed-C (130-Pin size #23 38999 Connector)
PMC/XMC rear I/O from PMC/XMC Site 2 on the carrier (ACEX-46xx)
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
Signal Name
J24_RIO0_P
J24_RIO0_N
J24_RIO1_P
J24_RIO1_N
J24_RIO2_P
J24_RIO2_N
J24_RIO3_P
J24_RIO3_N
GND
J24_RIO4_P
J24_RIO4_N
GND
J24_RIO5_P
J24_RIO5_N
GND
J24_RIO6_P
J24_RIO6_N
J24_RIO7_P
J24_RIO7_N
J24_RIO8_P
J24_RIO8_N
J24_RIO9_P
J24_RIO9_N
J24_RIO10_P
J24_RIO10_N
GND
J24_RIO11_P
J24_RIO11_N
J24_RIO12_P
J24_RIO12_N
No connect
J24_RIO13_P
J24_RIO13_N
Pin
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
Acromag, Inc. Tel: 248-295-0310
Signal Name
J24_RIO14_P
J24_RIO14_N
GND
J24_RIO15_P
J24_RIO15_N
GND
GND
J24_RIO16_P
J24_RIO16_N
J24_RIO17_P
J24_RIO17_N
GND
GND
J24_RIO18_P
J24_RIO18_N
GND
J24_RIO19_P
J24_RIO19_N
J24_RIO20_P
J24_RIO20_N
GND
J24_RIO21_P
J24_RIO21_N
J24_RIO22_P
J24_RIO22_N
GND
J24_RIO23_P
J24_RIO23_N
J24_RIO24_P
J24_RIO24_N
GND
J24_RIO25_P
J24_RIO25_N
Pin
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
Signal Name
J24_RIO26_P
J24_RIO26_N
GND
J24_RIO27_P
J24_RIO27_N
J24_RIO28_P
J24_RIO28_N
GND
J24_RIO29_P
J24_RIO29_N
GND
J24_RIO30_P
J24_RIO30_N
GND
J24_RIO31_P
J24_RIO31_N
GND
J26_SIO0_GCLK_P
J26_SIO0_GCLK_
N
J26_SIO1_P
J26_SIO1_N
J26_SIO2_P
J26_SIO2_N
J26_SIO3_P
J26_SIO3_N
J26_SIO4_P
J26_SIO4_N
GND
J26_SIO5_P
J26_SIO5_N
GND
J26_SIO6_P
J26_SIO6_N
- 35 -
Pin
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
Signal Name
GND
J26_SIO7_P
J26_SIO7_N
J26_SIO8_P
J26_SIO8_N
GND
J26_SIO9_P
J26_SIO9_N
J26_SIO10_P
J26_SIO10_N
No connect
J26_SIO11_P
J26_SIO11_N
GND
J26_SIO12_P
J26_SIO12_N
GND
J26_SIO13_P
J26_SIO13_N
GND
J26_SIO14_P
J26_SIO14_N
GND
J26_SIO15_P
J26_SIO15_N
J26_SIO16_P
J26_SIO16_N
J26_SIO17_P
J26_SIO17_N
J26_SIO18_GCLK_P
J26_SIO18_GCLK_N
www.acromag.com
ACEX-FP-IO-0x User’s Manual
COM Express Front Panel for Ruggedized/Military Packaging
J6 – Keyed-A (6-Pin size #12 38999 Connectors)
Input power connector
Pin
1
2
3
4
5
6
Signal Name
PWR_BTN
Reserved (DO NOT USE)
INPUT_PWR
INPUT_GND
Reserved (DO NOT USE)
GND
J7 (160-Pin SEARAY Mezzanine Connector)
Signals between Site 1 mezzanine board to 38999 connector, J3.
A
B
C
D
E
F
G
H
1
J14_RIO0_P
J14_RIO2_N
14_RIO7_N
J14_RIO5_N
J14_RIO10_N
J14_RIO12_P
J14_RIO14_N
J14_RIO18_N
2
J14_RIO0_N
J14_RIO2_P
J14_RIO7_P
J14_RIO5_P
J14_RIO10_P
J14_RIO12_N
J14_RIO14_P
J14_RIO18_P
3
GND
GND
GND
GND
GND
GND
GND
GND
4
J14_RIO3_P
J14_RIO4_P
J14_RIO8_P
J14_RIO1_P
J14_RIO11_P
J14_RIO22_N
J14_RIO31_N
J16_SIO18_GCLK_P
5
J14_RIO3_N
J14_RIO4_N
J14_RIO8_N
J14_RIO1_N
J14_RIO11_N
J14_RIO22_P
J14_RIO31_P
J16_SIO18_GCLK_N
6
GND
GND
GND
GND
GND
GND
GND
GND
7
J14_RIO6_P
J14_RIO13_P
J14_RIO16_P
J14_RIO9_P
J14_RIO21_N
J16_SIO4_N
J16_SIO12_N
NC
8
J14_RIO6_N
J14_RIO13_N
J14_RIO16_N
J14_RIO9_N
J14_RIO21_P
J16_SIO4_P
J16_SIO12_P
NC
9
GND
GND
GND
GND
GND
GND
GND
NC
10
J14_RIO15_P
J14_RIO19_P
J14_RIO20_P
J14_RIO17_P
J14_RIO24_N
J14_RIO30_P
J16_SIO13_N
NC
11
J14_RIO15_N
J14_RIO19_N
J14_RIO20_N
J14_RIO17_N
J14_RIO24_P
J14_RIO30_N
J16_SIO13_P
NC
12
GND
GND
GND
GND
GND
GND
GND
NC
13
J14_RIO23_P
J14_RIO29_P
J16_SIO11_N
J14_RIO25_P
J14_RIO26_P
J16_SIO0_GCLK_P
J16_SIO15_N
NC
14
J14_RIO23_N
J14_RIO29_N
J16_SIO11_P
J14_RIO25_N
J14_RIO26_N
J16_SIO0_GCLK_N
J16_SIO15_P
NC
15
GND
GND
GND
GND
GND
GND
GND
NC
16
J14_RIO28_P
J16_SIO3_N
J16_SIO10_P
J16_SIO1_P
J16_SIO7_N
J16_SIO8_N
J16_SIO14_N
NC
17
J14_RIO28_N
J16_SIO3_P
J16_SIO10_N
J16_SIO1_N
J16_SIO7_P
J16_SIO8_P
J16_SIO14_P
NC
18
GND
GND
GND
GND
GND
GND
GND
NC
19
J16_SIO5_P
J16_SIO6_P
J16_SIO17_P
J14_RIO27_P
J16_SIO2_P
J16_SIO9_P
J16_SIO16_P
NC
20
J16_SIO5_N
J16_SIO6_N
J16_SIO17_N
J14_RIO27_N
J16_SIO2_N
J16_SIO9_N
J16_SIO16_N
NC
Acromag, Inc. Tel: 248-295-0310
- 36 -
www.acromag.com
ACEX-FP-IO-0x User’s Manual
COM Express Front Panel for Ruggedized/Military Packaging
J8 (160-Pin SEARAY Mezzanine Connector)
Signals between system and Site 1 mezzanine board.
A
B
C
D
E
F
G
H
1
3.3V
3.3V
3.3V
J14_RIO15_N
J14_RIO19_P
J14_RIO18_N
J16_SIO7_P
J14_RIO23_P
2
5V
5V
5V
J14_RIO15_P
J14_RIO19_N
J14_RIO18_P
J16_SIO7_N
J14_RIO23_N
3
12V
12V
GND
J14_RIO13_N
J14_RIO11_P
J14_RIO14_P
J16_SIO8_P
J14_RIO25_P
4
J16_SIO4_N
J16_SIO14_N
J14_RIO12_N
J14_RIO13_P
J14_RIO11_N
J14_RIO14_N
J16_SIO8_N
J14_RIO25_N
5
J16_SIO4_P
J16_SIO14_P
J14_RIO12_P
J16_SIO2_N
J14_RIO24_N
J14_RIO7_N
J16_SIO9_P
J14_RIO27_P
6
J14_RIO31_P
J14_RIO8_P
J16_SIO5_N
J16_SIO2_P
J14_RIO24_P
J14_RIO7_P
J16_SIO9_N
J14_RIO27_N
7
J14_RIO31_N
J14_RIO8_N
J16_SIO5_P
J14_RIO9_N
J16_SIO1_P
J14_RIO10_N
J16_SIO10_P
J14_RIO29_P
8
GND
GND
GND
J14_RIO9_P
J16_SIO1_N
J14_RIO10_P
J16_SIO10_N
J14_RIO29_N
9
J16_SIO6_P
J14_RIO26_N
J16_SIO15_P
J16_SIO3_P
J14_RIO20_P
J14_RIO6_N
J16_SIO11_P
J14_RIO17_P
10
J16_SIO6_N
J14_RIO26_P
J16_SIO15_N
J16_SIO3_N
J14_RIO20_N
J14_RIO6_P
J16_SIO11_N
J14_RIO17_N
11
J14_RIO4_P
J14_RIO0_N
J14_RIO30_N
J14_RIO5_N
J14_RIO3_P
J14_RIO28_P
J16_SIO12_P
J14_RIO22_P
12
J14_RIO4_N
J14_RIO0_P
J14_RIO30_P
J14_RIO5_P
J14_RIO3_N
J14_RIO28_N
J16_SIO12_N
J14_RIO22_N
13
GND
GND
GND
WAKE0#
I2C_DAT
GPI_1
GPI_2
GPI_3
14
J16_SIO0_GCLK_P
J16_SIO13_N
J16_SIO16_N
PLT_RST#
I2C_CLK
GPO_1
GPO_2
GPO_3
15
J16_SIO0_GCLK_N
J16_SIO13_P
J16_SIO16_P
SATA1_TX_P
GND
GND
GND
GND
16
J16_SIO18_GCLK_N
J14_RIO2_N
J14_RIO16_P
SATA1_TX_N
PCIE0_RX_N
PCIE0_TX_N
PCIE2_TX_P
PCIE3_TX_P
17
J16_SIO18_GCLK_P
J14_RIO2_P
J14_RIO16_N
SATA1_RX_N
PCIE0_RX_P
PCIE0_TX_P
PCIE2_TX_N
PCIE3_TX_N
18
GND
GND
GND
SATA1_RX_P
GND
GND
GND
GND
19
J16_SIO17_N
J14_RIO21_P
J14_RIO1_N
PCIE1_RX_P
PCIE_CLK_PEG_N
PCIE1_TX_N
PCIE2_RX_P
PCIE3_RX_P
20
J16_SIO17_P
J14_RIO21_N
J14_RIO1_P
PCIE1_RX_N
PCIE_CLK_PEG_P
PCIE1_TX_P
PCIE2_RX_N
PCIE3_RX_N
Acromag, Inc. Tel: 248-295-0310
- 37 -
www.acromag.com
ACEX-FP-IO-0x User’s Manual
COM Express Front Panel for Ruggedized/Military Packaging
J9 (160-Pin SEARAY Mezzanine Connector)
Signals between Site 2 mezzanine board and 38999 connector, J5.
A
B
C
D
E
F
G
H
1
J24_RIO0_P
J24_RIO2_N
J24_IO7_N
J24_RIO5_N
J24_RIO10_N
J24_RIO12_P
J24_RIO14_N
J24_RIO18_N
2
J24_RIO0_N
J24_RIO2_P
J24_RIO7_P
J24_RIO5_P
J24_RIO10_P
J24_RIO12_N
J24_RIO14_P
J24_RIO18_P
3
GND
GND
GND
GND
GND
GND
GND
GND
4
J24_RIO3_P
J24_RIO4_P
J24_RIO8_P
J24_RIO1_P
J24_RIO11_P
J24_RIO22_N
J24_RIO31_N
J26_SIO18_GCLK_P
5
J24_RIO3_N
J24_RIO4_N
J24_RIO8_N
J24_RIO1_N
J24_RIO11_N
J24_RIO22_P
J24_RIO31_P
J26_SIO18_GCLK_N
6
GND
GND
GND
GND
GND
GND
GND
GND
7
J24_RIO6_P
J24_RIO13_P
J24_RIO16_P
J24_RIO9_P
J24_RIO21_N
J26_SIO4_N
J26_SIO12_N
NC
8
J24_RIO6_N
J24_RIO13_N
J24_RIO16_N
J24_RIO9_N
J24_RIO21_P
J26_SIO4_P
J26_SIO12_P
NC
9
GND
GND
GND
GND
GND
GND
GND
NC
10
J24_RIO15_P
J24_RIO19_P
J24_RIO20_P
J24_RIO17_P
J24_RIO24_N
J24_RIO30_P
J26_SIO13_N
NC
11
J24_RIO15_N
J24_RIO19_N
J24_RIO20_N
J24_RIO17_N
J24_RIO24_P
J24_RIO30_N
J26_SIO13_P
NC
12
GND
GND
GND
GND
GND
GND
GND
NC
13
J24_RIO23_P
J24_RIO29_P
J26_SIO11_N
J24_RIO25_P
J24_RIO26_P
J26_SIO0_GCLK_P
J26_SIO15_N
NC
14
J24_RIO23_N
J24_RIO29_N
J26_SIO11_P
J24_RIO25_N
J24_RIO26_N
J26_SIO0_GCLK_N
J26_SIO15_P
NC
15
GND
GND
GND
GND
GND
GND
GND
NC
16
J24_RIO28_P
J26_SIO3_N
J26_SIO10_P
J26_SIO1_P
J26_SIO7_N
J26_SIO8_N
J26_SIO14_N
NC
17
J24_RIO28_N
J26_SIO3_P
J26_SIO10_N
J26_SIO1_N
J26_SIO7_P
J26_SIO8_P
J26_SIO14_P
NC
18
GND
GND
GND
GND
GND
GND
GND
NC
19
J26_SIO5_P
J26_SIO6_P
J26_SIO17_P
J24_RIO27_P
J26_SIO2_P
J26_SIO9_P
J26_SIO16_P
NC
20
J26_SIO5_N
J26_SIO6_N
J26_SIO17_N
J24_RIO27_N
J26_SIO2_N
J26_SIO9_N
J26_SIO16_N
NC
Acromag, Inc. Tel: 248-295-0310
- 38 -
www.acromag.com
ACEX-FP-IO-0x User’s Manual
COM Express Front Panel for Ruggedized/Military Packaging
J10 (160-Pin SEARAY Mezzanine Connector)
Signals between system and Site 2 mezzanine board.
A
B
C
D
E
F
G
H
1
3.3V
3.3V
3.3V
J24_RIO15_N
J24_RIO19_P
J24_RIO18_N
J26_SIO7_P
J24_RIO23_P
2
5V
5V
5V
J24_RIO15_P
J24_RIO19_N
J24_RIO18_P
J26_SIO7_N
J24_RIO23_N
3
12V
12V
GND
J24_RIO13_N
J24_RIO11_P
J24_RIO14_P
J26_SIO8_P
J24_RIO25_P
4
J26_SIO4_N
J26_SIO14_N
J24_RIO12_N
J24_RIO13_P
J24_RIO11_N
J24_RIO14_N
J26_SIO8_N
J24_RIO25_N
5
J26_SIO4_P
J26_SIO14_P
J24_RIO12_P
J26_SIO2_N
J24_RIO24_N
J24_RIO7_N
J26_SIO9_P
J24_RIO27_P
6
J24_RIO31_P
J24_RIO8_P
J26_SIO5_N
J26_SIO2_P
J24_RIO24_P
J24_RIO7_P
J26_SIO9_N
J24_RIO27_N
7
J24_RIO31_N
J24_RIO8_N
J26_SIO5_P
J24_RIO9_N
J26_SIO1_P
J24_RIO10_N
J26_SIO10_P
J24_RIO29_P
8
GND
GND
GND
J24_RIO9_P
J26_SIO1_N
J24_RIO10_P
J26_SIO10_N
J24_RIO29_N
9
J26_SIO6_P
J24_RIO26_N
J26_SIO15_P
J26_SIO3_P
J24_RIO20_P
J24_RIO6_N
J26_SIO11_P
J24_RIO17_P
10
J26_SIO6_N
J24_RIO26_P
J26_SIO15_N
J26_SIO3_N
J24_RIO20_N
J24_RIO6_P
J26_SIO11_N
J24_RIO17_N
11
J24_RIO4_P
J24_RIO0_N
J24_RIO30_N
J24_RIO5_N
J24_RIO3_P
J24_RIO28_P
J26_SIO12_P
J24_RIO22_P
12
J24_RIO4_N
J24_RIO0_P
J24_RIO30_P
J24_RIO5_P
J24_RIO3_N
J24_RIO28_N
J26_SIO12_N
J24_RIO22_N
13
GND
GND
GND
J26_DP00_N
J26_DP04_N
J26_DP08_N
J26_DP12_N
J26_DP16_N
14
J26_SIO0_GCLK_P
J26_SIO13_N
J26_SIO16_N
J26_DP00_P
J26_DP04_P
J26_DP08_P
J26_DP12_P
J26_DP16_P
15
J26_SIO0_GCLK_N
J26_SIO13_P
J26_SIO16_P
J26_DP01_N
J26_DP05_N
J26_DP09_N
J26_DP13_N
J26_DP17_N
16
J26_SIO18_GCLK_N
J24_RIO2_N
J24_RIO16_P
J26_DP01_P
J26_DP05_P
J26_DP09_P
J26_DP13_P
J26_DP17_P
17
J26_SIO18_GCLK_P
J24_RIO2_P
J24_RIO16_N
J26_DP02_N
J26_DP06_N
J26_DP10_N
J26_DP14_N
J26_DP18_N
18
GND
GND
GND
J26_DP02_P
J26_DP06_P
J26_DP10_P
J26_DP14_P
J26_DP18_P
19
J26_SIO17_N
J24_RIO21_P
J24_RIO1_N
J26_DP03_N
J26_DP07_N
J26_DP11_N
J26_DP15_N
J26_DP19_N
20
J26_SIO17_P
J24_RIO21_N
J24_RIO1_P
J26_DP03_P
J26_DP07_P
J26_DP11_P
J26_DP15_P
J26_DP19_P
Acromag, Inc. Tel: 248-295-0310
- 39 -
www.acromag.com
ACEX-FP-IO-0x User’s Manual
COM Express Front Panel for Ruggedized/Military Packaging
Handling
Modules should be handled in ESD-safe work areas in order to prevent
damage to sensitive components from electrostatic discharges. These areas
must be designed and maintained to prevent ESD damage.
ESD Safe Work Area Guidelines
1. Module should be handled at properly designated work areas only.
2. Designated ESD safe work areas must be checked periodically to
ensure their continued safety from ESD. The areas should be
monitored for the following:
a. Proper grounding methods.
b. Static dissipation of work surfaces.
c. Static dissipation of floor surfaces.
d. Operation of ion blowers and ion air guns.
3. Designated work areas must be kept free of static generating
materials such as styrofoam, vinyl, plastic, fabrics or any other static
generating materials.
4. Work areas must be kept clean and neat in order to prevent
contamination of the work area.
5. Modules should be handled by the edges. Avoid touching the
component leads.
NOTE: When not installed in a system, modules must be enclosed in
shielded bags or boxes. There are three types of ESD protective
enclosure materials this module was shipped in an approved ESD
bag.
6. Whenever handling the module the operator must be properly
grounded by one of the following:
a. Wearing a wrist strap connected to earth ground.
b. Wearing heel grounders and have both feet on a static
dissipative floor surface.
7. Stacking of modules should be avoided to prevent physical damage.
Acromag, Inc. Tel: 248-295-0310
- 40 -
www.acromag.com
ACEX-FP-IO-0x User’s Manual
6.0
COM Express Front Panel for Ruggedized/Military Packaging
Service and Repair
Surface-Mounted Technology (SMT) boards are generally difficult to repair.
It is highly recommended that a non-functioning board be returned to
Acromag for repair. The board can be easily damaged unless special SMT
repair and service tools are used. Further, Acromag has automated test
equipment that thoroughly checks the performance of each board. When a
board is first produced and when any repair is made, it is tested before
shipment.
Service and Repair Assistance
Please refer to Acromag's Service Policy Bulletin or contact Acromag for
complete details on how to obtain parts and repair.
Preliminary Service Procedure
CAUTION: POWER MUST
BE TURNED OFF BEFORE
REMOVING OR INSERTING
BOARDS
Before beginning repair, be sure that all of the procedures in the
"Preparation for Use" section have been followed. Also, refer to the
documentation of your board to verify that it is correctly configured.
Replacement of the board with one that is known to work correctly is a good
technique to isolate a faulty board.
Where to Get Help
If you continue to have problems, your next step should be to visit the
Acromag worldwide web site at http://www.acromag.com. Our web site
contains the most up-to-date product and software information.
Acromag’s application engineers can also be contacted directly for technical
assistance via email, telephone, or FAX through the contact information
listed at the bottom of this page. When needed, complete repair services
are also available.
Acromag, Inc. Tel: 248-295-0310
- 41 -
www.acromag.com
ACEX-FP-IO-0x User’s Manual
7.0
COM Express Front Panel for Ruggedized/Military Packaging
Specifications
Physical
ACEX-FP-IO-01:
Height
Width
Board Thickness
68.58 mm (2.700 in)
125 mm (4.921 in)
2.36 mm (0.093 in)
Unit Weight:
6.13oz (0.1738Kg)
ACEX-FP-IO-02:
Height
Width
Board Thickness
68.58 mm (2.700 in)
200 mm (7.874 in)
2.36 mm (0.093 in)
Unit Weight:
9.37oz (0.2655Kg)
Power Requirements
Note: The maximum current
supplied to the Carrier/Module
cannot exceed 15 Amps.
Minimum Input Voltage +10V DC
Maximum Input Voltage +36V DC
Environmental
Operating Temperature
Operating Temperature
Model
ACEX-FP-IO-01
ACEX-FP-IO-02
-40C to 85C
Relative Humidity: 5-95% Non-Condensing.
Storage Temperature: -55C to 100C.
Acromag, Inc. Tel: 248-295-0310
- 42 -
www.acromag.com
ACEX-FP-IO-0x User’s Manual
COM Express Front Panel for Ruggedized/Military Packaging
Appendix
The table below is the 500-Pin SEARAY pin-out as it relates to the technology type.
Note: Not all signals listed below are used in the ACEX-FP-IO-0x design.
500 - Pin SEARAY Connector pin-out by Type
DDI 1
Signal Name
DPB_TX0_N
DPB_TX0_P
DPB_TX1_N
DPB_TX1_P
DPB_TX2_N
DPB_TX2_P
DPB_TX3_N
DPB_TX3_P
DPB_AUX_SEL
DPB_CTRL_AUX_N
DPB_CTRL_AUX_P
DPB_HPD
Description
Digital Display Interface 1 - Output Differential Pair 0 Negative
Digital Display Interface 1 - Output Differential Pair 0 Positive
Digital Display Interface 1 - Output Differential Pair 1 Negative
Digital Display Interface 1 - Output Differential Pair 1 Positive
Digital Display Interface 1 - Output Differential Pair 2 Negative
Digital Display Interface 1 - Output Differential Pair 2 Positive
Digital Display Interface 1 - Output Differential Pair 3 Negative
Digital Display Interface 1 - Output Differential Pair 3 Positive
Digital Display Interface 1 - AUX Function Select
Digital Display Interface 1 - DVI/HDMI/DP AUX Control Negative
Digital Display Interface 1 - DVI/HDMI/DP AUX Control Positive
Digital Display Interface 1 - Hot Plug Detect
SEARAY
Pin
H37
H38
K37
K38
J35
J36
G35
G36
D36
F37
F38
D37
DDI 2
Signal Name
DPC_TX0_N
DPC_TX0_P
DPC_TX1_N
DPC_TX1_P
DPC_TX2_N
DPC_TX2_P
DPC_TX3_N
DPC_TX3_P
DPC_AUX_SEL
DPC_CTRL_AUX_N
DPC_CTRL_AUX_P
DPC_HPD
Description
Digital Display Interface 2 - Output Differential Pair 0 Negative
Digital Display Interface 2 - Output Differential Pair 0 Positive
Digital Display Interface 2 - Output Differential Pair 1 Negative
Digital Display Interface 2 - Output Differential Pair 1 Positive
Differential Pair - "DDI2_PAIR2-"
Differential Pair - "DDI2_PAIR2+"
Digital Display Interface 2 - Output Differential Pair 3 Negative
Digital Display Interface 2 - Output Differential Pair 3 Positive
Digital Display Interface 2 - AUX Function Select
Digital Display Interface 2 - DVI/HDMI/DP AUX Control Negative
Digital Display Interface 2 - DVI/HDMI/DP AUX Control Positive
Digital Display Interface 2 - Hot Plug Detect
Acromag, Inc. Tel: 248-295-0310
- 43 -
SEARAY
Pin
D29
D30
F29
F30
E27
E28
C27
C28
B32
E31
E32
C33
www.acromag.com
ACEX-FP-IO-0x User’s Manual
COM Express Front Panel for Ruggedized/Military Packaging
DDI 3
Signal Name
DPD_TX0_N
DPD_TX0_P
DPD_TX1_N
DPD_TX1_P
DPD_TX2_N
DPD_TX2_P
DPD_TX3_N
DPD_TX3_P
DPD_AUX_SEL
DPD_CTRL_AUX_N
DPD_CTRL_AUX_P
DPD_HPD
Description
Digital Display Interface 3 - Output Differential Pair 0 Negative
Digital Display Interface 3 - Output Differential Pair 0 Positive
Digital Display Interface 3 - Output Differential Pair 1 Negative
Digital Display Interface 3 - Output Differential Pair 1 Positive
Digital Display Interface 3 - Output Differential Pair 2 Negative
Digital Display Interface 3 - Output Differential Pair 2 Positive
Digital Display Interface 3 - Output Differential Pair 3 Negative
Digital Display Interface 3 - Output Differential Pair 3 Positive
Digital Display Interface 3 - AUX Function Select
Digital Display Interface 3 - DVI/HDMI/DP AUX Control Negative
Digital Display Interface 3 - DVI/HDMI/DP AUX Control Positive
Digital Display Interface 3 - Hot Plug Detect
SEARAY
Pin
H33
H34
K33
K34
J31
J32
G31
G32
D33
F33
F34
D34
eDP
Signal Name
EDP_TX0_N
EDP_TX0_P
EDP_TX1_N
EDP_TX1_P
EDP_TX2_N
EDP_TX2_P
EDP_TX3_N
EDP_TX3_P
EDP_VDDEN
EDP_BKLTEN
EDP_BKLTCTL
EDP_AUX_P
EDP_AUX_N
EDP_HPD
SEARAY
Pin
E23
E24
D25
D26
F25
F26
C23
C24
C22
A28
A27
H22
H21
A26
Description
eDP Differential Pair 0 Negative
eDP Differential Pair 0 Positive
eDP Differential Pair 1 Negative
eDP Differential Pair 1 Positive
eDP Differential Pair 2 Negative
eDP Differential Pair 2 Positive
eDP Differential Pair 3 Negative
eDP Differential Pair 3 Positive
eDP Power Enable
eDP Backlight Enable
eDP Backlight Brightness Control
eDP AUX Signal Positive
eDP AUX Signal Negative
eDP Hot Plug Detect
Acromag, Inc. Tel: 248-295-0310
- 44 -
www.acromag.com
ACEX-FP-IO-0x User’s Manual
COM Express Front Panel for Ruggedized/Military Packaging
VGA
Signal Name
VGA_RED
VGA_GRN
VGA_BLU
VGA_HSYNC
VGA_VSYNC
VGA_I2C_CK
VGA_I2C_DAT
SEARAY
Pin
B44
B45
B43
D45
D44
D46
C46
Description
Analog Video Output Red
Analog Video Output Green
Analog Video Output Blue
VGA Output Horizontal Sync
VGA Output Vertical Sync
Display Data Channel (DDC) Clock Line
Display Data Channel (DDC) Data Line
SATA
Signal Name
SATA0_RX_N
SATA0_RX_P
SATA0_TX_N
SATA0_TX_P
SATA1_RX_N
SATA1_RX_P
SATA1_TX_N
SATA1_TX_P
SATA_ACT#
Description
SATA0 Receive Differential Pair Negative
SATA0 Receive Differential Pair Positive
SATA0 Transmit Differential Pair Negative
SATA0 Transmit Differential Pair Positive
SATA1 Receive Differential Pair Negative
SATA1 Receive Differential Pair Positive
SATA1 Transmit Differential Pair Negative
SATA1 Transmit Differential Pair Positive
ATA (Parallel and Serial) or SAS Activity Indicator Signal
SEARAY
Pin
J39
J40
K41
K42
G39
G40
H41
H42
C40
USB0
Signal Name
USB0_+5V
USB0_P
USB0_N
USB0_SSRX_P
USB0_SSRX_N
USB0_SSTX_P
USB0_SSTX_N
Description
USB0 Positive 5V from Carrier
USB0 Differential Pair - "USB0+"
USB0 Differential Pair - "USB0-"
USB0 USB 3.0 SuperSpeed Receive Positive
USB0 USB 3.0 SuperSpeed Receive Negative
USB0 USB 3.0 SuperSpeed Transmit Positive
USB0 USB 3.0 SuperSpeed Transmit Negative
Acromag, Inc. Tel: 248-295-0310
- 45 -
SEARAY
Pin
A21
B21
B22
J47
J48
K49
K50
www.acromag.com
ACEX-FP-IO-0x User’s Manual
COM Express Front Panel for Ruggedized/Military Packaging
USB1
Signal Name
USB1_+5V
USB1_P
USB1_N
USB1_SSRX_P
USB1_SSRX_N
USB1_SSTX_P
USB1_SSTX_N
Description
USB1 Positive 5V from Carrier
USB1 Differential Pair - "USB1+"
USB1 Differential Pair - "USB1-"
USB1 USB 3.0 SuperSpeed Receive Positive
USB1 USB 3.0 SuperSpeed Receive Negative
USB1 USB 3.0 SuperSpeed Transmit Positive
USB1 USB 3.0 SuperSpeed Transmit Negative
SEARAY
Pin
C21
D21
D22
G47
G48
H49
H50
USB2
Signal Name
USB2_+5V
USB2_P
USB2_N
USB2_SSRX_P
USB2_SSRX_N
USB2_SSTX_P
USB2_SSTX_N
Description
USB2 Positive 5V from Carrier
USB2 Differential Pair - "USB2+"
USB2 Differential Pair - "USB2-"
USB2 USB 3.0 SuperSpeed Receive Positive
USB2 USB 3.0 SuperSpeed Receive Negative
USB2 USB 3.0 SuperSpeed Transmit Positive
USB2 USB 3.0 SuperSpeed Transmit Negative
SEARAY
Pin
E21
F21
F22
J43
J44
K45
K46
USB3
Signal Name
USB3_+5V
USB3_P
USB3_N
USB3_SSRX_P
USB3_SSRX_N
USB3_SSTX_P
USB3_SSTX_N
Description
USB3 Positive 5V from Carrier
USB3 Differential Pair - "USB3+"
USB3 Differential Pair - "USB3-"
USB3 USB 3.0 SuperSpeed Receive Positive
USB3 USB 3.0 SuperSpeed Receive Negative
USB3 USB 3.0 SuperSpeed Transmit Positive
USB3 USB 3.0 SuperSpeed Transmit Negative
SEARAY
Pin
A25
B25
B26
G43
G44
H45
H46
USB4
Signal Name
USB4_+5V
USB4_P
USB4_N
SEARAY
Pin
A29
B29
B30
Description
USB4 Positive 5V from Carrier
USB4 Differential Pair - "USB4+"
USB4 Differential Pair - "USB4-"
Acromag, Inc. Tel: 248-295-0310
- 46 -
www.acromag.com
ACEX-FP-IO-0x User’s Manual
COM Express Front Panel for Ruggedized/Military Packaging
USB5
Signal Name
USB5_+5V
USB5_P
USB5_N
SEARAY
Pin
B31
C31
C32
Description
USB5 Positive 5V from Carrier
USB5 Differential Pair - "USB5+"
USB5 Differential Pair - "USB5-"
Serial
Signal Name
UART_TX0_P
UART_TX0_N
UART_RX0_P
UART_RX0_N
UART_TX1_P
UART_TX1_N
UART_RX1_P
UART_RX1_N
SEARAY
Pin
B33
B34
B35
B36
B37
B38
B39
B40
Description
General Purpose Serial Port 0 from Carrier Transmitter Positive
General Purpose Serial Port 0 from Carrier Transmitter Negative
General Purpose Serial Port 0 from Carrier Receiver Positive
General Purpose Serial Port 0 from Carrier Receiver Negative
General Purpose Serial Port 1 from Carrier Transmitter Positive
General Purpose Serial Port 1 from Carrier Transmitter Negative
General Purpose Serial Port 1 from Carrier Receiver Positive
General Purpose Serial Port 1 from Carrier Receiver Negative
LAN0
Signal Name
GBE0_MDI0_P
GBE0_MDI0_N
GBE0_MDI1_P
GBE0_MDI1_N
GBE0_MDI2_P
GBE0_MDI2_N
GBE0_MDI3_P
GBE0_MDI3_N
GBE0_ACT#
GBE0_LINK#
GBE0_L1000#
Description
Gigabit Ethernet Controller 0 from Module - MDI Differential Pair 0 Positive
Gigabit Ethernet Controller 0 from Module - MDI Differential Pair 0 Negative
Gigabit Ethernet Controller 0 from Module - MDI Differential Pair 1 Positive
Gigabit Ethernet Controller 0 from Module - MDI Differential Pair 1 Negative
Gigabit Ethernet Controller 0 from Module - MDI Differential Pair 2 Positive
Gigabit Ethernet Controller 0 from Module - MDI Differential Pair 2 Negative
Gigabit Ethernet Controller 0 from Module - MDI Differential Pair 3 Positive
Gigabit Ethernet Controller 0 from Module - MDI Differential Pair 3 Negative
Gigabit Ethernet Controller 0 from Module - Activity Indicator
Gigabit Ethernet Controller 0 from Module - Link Indicator
Gigabit Ethernet Controller 0 from Module - 1000 Mb/s Link Indicator
Acromag, Inc. Tel: 248-295-0310
- 47 -
SEARAY
Pin
D47
D48
C47
C48
B47
B48
A47
A48
F49
E49
E47
www.acromag.com
ACEX-FP-IO-0x User’s Manual
COM Express Front Panel for Ruggedized/Military Packaging
LAN1
Signal Name
GBE1_MDI0_P
GBE1_MDI0_N
GBE1_MDI1_P
GBE1_MDI1_N
GBE1_MDI2_P
GBE1_MDI2_N
GBE1_MDI3_P
GBE1_MDI3_N
GBE1_ACT#
GBE1_LINK#
GBE1_1V9
Description
Gigabit Ethernet Controller 1 from Carrier - MDI Differential Pair 0 Positive
Gigabit Ethernet Controller 1 from Carrier - MDI Differential Pair 0 Negative
Gigabit Ethernet Controller 1 from Carrier - MDI Differential Pair 1 Positive
Gigabit Ethernet Controller 1 from Carrier - MDI Differential Pair 1 Negative
Gigabit Ethernet Controller 1 from Carrier - MDI Differential Pair 2 Positive
Gigabit Ethernet Controller 1 from Carrier - MDI Differential Pair 2 Negative
Gigabit Ethernet Controller 1 from Carrier - MDI Differential Pair 3 Positive
Gigabit Ethernet Controller 1 from Carrier - MDI Differential Pair 3 Negative
Gigabit Ethernet Controller 1 from Carrier - Activity Indicator
Gigabit Ethernet Controller 1 from Carrier - Link Indicator
External 1.9V Reference Voltage from Carrier for Gigabit Ethernet Controller 1
SEARAY
Pin
D49
D50
C49
C50
B49
B50
A49
A50
F50
E50
E48
Audio
Signal Name
LINE-IN_R
LINE-IN_L
LINE-OUT_R
LINE-OUT_L
AUDIO_GND
Description
Right Channel Audio Line In from CODEC on Carrier
Left Channel Audio Line In from CODEC on Carrier
Right Channel Audio Line Out from CODEC on Carrier
Left Channel Audio Line Out from CODEC on Carrier
AUDIO_GND connected to Digital GND near CODEC on Carrier
Acromag, Inc. Tel: 248-295-0310
- 48 -
SEARAY
Pin
A44
A45
A42
B42
A43
www.acromag.com
ACEX-FP-IO-0x User’s Manual
COM Express Front Panel for Ruggedized/Military Packaging
PCIE
Signal Name
PCIE0_RX_N
PCIE0_RX_P
PCIE0_TX_N
PCIE0_TX_P
PCIE1_RX_N
PCIE1_RX_P
PCIE1_TX_P
PCIE1_TX_N
PCIE2_RX_N
PCIE2_RX_P
PCIE2_TX_N
PCIE2_TX_P
PCIE3_RX_N
PCIE3_RX_P
PCIE3_TX_N
PCIE3_TX_P
CLK_PEG_N
CLK_PEG_P
Description
PCI Express Lane 0 Receive Differential Pair Negative
PCI Express Lane 0 Receive Differential Pair Positive
PCI Express Lane 0 Transmit Differential Pair Negative
PCI Express Lane 0 Transmit Differential Pair Positive
PCI Express Lane 1 Receive Differential Pair Negative
PCI Express Lane 1 Receive Differential Pair Positive
PCI Express Lane 1 Transmit Differential Pair Positive
PCI Express Lane 1 Transmit Differential Pair Negative
PCI Express Lane 2 Receive Differential Pair Negative
PCI Express Lane 2 Receive Differential Pair Positive
PCI Express Lane 2 Transmit Differential Pair Negative
PCI Express Lane 2 Transmit Differential Pair Positive
PCI Express Lane 3 Receive Differential Pair Negative
PCI Express Lane 3 Receive Differential Pair Positive
PCI Express Lane 3 Transmit Differential Pair Negative
PCI Express Lane 3 Transmit Differential Pair Positive
PCIe/PEG Reference Clock Output Negative
PCIe/PEG Reference Clock Output Positive
Acromag, Inc. Tel: 248-295-0310
- 49 -
SEARAY
Pin
G23
G24
H25
H26
J23
J24
K25
K26
G27
G28
H29
H30
J27
J28
K29
K30
K21
K22
www.acromag.com
ACEX-FP-IO-0x User’s Manual
COM Express Front Panel for Ruggedized/Military Packaging
PMC Site 1
Signal Name
J14_RIO0_N
J14_RIO0_P
J14_RIO1_N
J14_RIO1_P
J14_RIO2_N
J14_RIO2_P
J14_RIO3_N
J14_RIO3_P
J14_RIO4_N
J14_RIO4_P
J14_RIO5_N
J14_RIO5_P
J14_RIO6_N
J14_RIO6_P
J14_RIO7_N
J14_RIO7_P
J14_RIO8_N
J14_RIO8_P
J14_RIO9_N
J14_RIO9_P
J14_RIO10_N
J14_RIO10_P
J14_RIO11_N
J14_RIO11_P
J14_RIO12_N
J14_RIO12_P
J14_RIO13_N
J14_RIO13_P
J14_RIO14_N
J14_RIO14_P
J14_RIO15_N
J14_RIO15_P
J14_RIO16_N
J14_RIO16_P
J14_RIO17_N
J14_RIO17_P
J14_RIO18_N
J14_RIO18_P
Description
PMC Site 1 Rear I/O Differential Pair "J14_RIO0-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO0+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO1-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO1+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO2-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO2+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO3-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO3+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO4-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO4+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO5-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO5+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO6-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO6+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO7-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO7+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO8-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO8+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO9-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO9+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO10-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO10+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO11-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO11+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO12-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO12+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO13-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO13+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO14-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO14+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO15-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO15+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO16-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO16+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO17-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO17+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO18-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO18+"
Acromag, Inc. Tel: 248-295-0310
- 50 -
SEARAY
Pin
D15
D16
C8
C9
C10
C11
D7
D8
C17
C16
C6
C7
B9
B10
B5
B6
B18
B17
C4
C5
B7
B8
D3
D4
C14
C15
C2
C3
B4
B3
D1
D2
D11
D12
B12
B11
B1
B2
www.acromag.com
ACEX-FP-IO-0x User’s Manual
J14_RIO19_N
J14_RIO19_P
J14_RIO20_N
J14_RIO20_P
J14_RIO21_N
J14_RIO21_P
J14_RIO22_N
J14_RIO22_P
J14_RIO23_N
J14_RIO23_P
J14_RIO24_N
J14_RIO24_P
J14_RIO25_N
J14_RIO25_P
J14_RIO26_N
J14_RIO26_P
J14_RIO27_N
J14_RIO27_P
J14_RIO28_N
J14_RIO28_P
J14_RIO29_N
J14_RIO29_P
J14_RIO30_N
J14_RIO30_P
J14_RIO31_N
J14_RIO31_P
COM Express Front Panel for Ruggedized/Military Packaging
PMC Site 1 Rear I/O Differential Pair "J14_RIO19-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO19+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO20-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO20+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO21-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO21+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO22-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO22+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO23-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO23+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO24-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO24+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO25-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO25+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO26-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO26+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO27-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO27+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO28-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO28+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO29-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO29+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO30-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO30+"
PMC Site 1 Rear I/O Differential Pair "J14_RIO31-"
PMC Site 1 Rear I/O Differential Pair "J14_RIO31+"
Acromag, Inc. Tel: 248-295-0310
- 51 -
A2
A3
A6
A7
A8
A9
B14
B13
A11
A10
A5
A4
A13
A12
B16
B15
A15
A14
C13
C12
A17
A16
C19
C18
A19
A18
www.acromag.com
ACEX-FP-IO-0x User’s Manual
COM Express Front Panel for Ruggedized/Military Packaging
XMC Site 1
Signal Name
J16_SIO0_GCLK_P
J16_SIO0_GCLK_N
J16_SIO1_P
J16_SIO1_N
J16_SIO2_P
J16_SIO2_N
J16_SIO3_P
J16_SIO3_N
J16_SIO4_P
J16_SIO4_N
J16_SIO5_P
J16_SIO5_N
J16_SIO6_P
J16_SIO6_N
J16_SIO7_P
J16_SIO7_N
J16_SIO8_P
J16_SIO8_N
J16_SIO9_P
J16_SIO9_N
J16_SIO10_P
J16_SIO10_N
J16_SIO11_P
J16_SIO11_N
J16_SIO12_P
J16_SIO12_N
J16_SIO13_P
J16_SIO13_N
J16_SIO14_P
J16_SIO14_N
J16_SIO15_P
J16_SIO15_N
J16_SIO16_P
J16_SIO16_N
J16_SIO17_P
J16_SIO17_N
J16_SIO18_GCLK_P
J16_SIO18_GCLK_N
Description
XMC Site 1 Rear I/O Differential Pair "J16_SIO0+"
XMC Site 1 Rear I/O Differential Pair "J16_SIO0-"
XMC Site 1 Rear I/O Differential Pair "J16_SIO1+"
XMC Site 1 Rear I/O Differential Pair "J16_SIO1-"
XMC Site 1 Rear I/O Differential Pair "J16_SIO2+"
XMC Site 1 Rear I/O Differential Pair "J16_SIO2-"
XMC Site 1 Rear I/O Differential Pair "J16_SIO3+"
XMC Site 1 Rear I/O Differential Pair "J16_SIO3-"
XMC Site 1 Rear I/O Differential Pair "J16_SIO4+"
XMC Site 1 Rear I/O Differential Pair "J16_SIO4-"
XMC Site 1 Rear I/O Differential Pair "J16_SIO5+"
XMC Site 1 Rear I/O Differential Pair "J16_SIO5-"
XMC Site 1 Rear I/O Differential Pair "J16_SIO6+"
XMC Site 1 Rear I/O Differential Pair "J16_SIO6-"
XMC Site 1 Rear I/O Differential Pair "J16_SIO7+"
XMC Site 1 Rear I/O Differential Pair "J16_SIO7-"
XMC Site 1 Rear I/O Differential Pair "J16_SIO8+"
XMC Site 1 Rear I/O Differential Pair "J16_SIO8-"
XMC Site 1 Rear I/O Differential Pair "J16_SIO9+"
XMC Site 1 Rear I/O Differential Pair "J16_SIO9-"
XMC Site 1 Rear I/O Differential Pair "J16_SIO10+"
XMC Site 1 Rear I/O Differential Pair "J16_SIO10-"
XMC Site 1 Rear I/O Differential Pair "J16_SIO11+"
XMC Site 1 Rear I/O Differential Pair "J16_SIO11-"
XMC Site 1 Rear I/O Differential Pair "J16_SIO12+"
XMC Site 1 Rear I/O Differential Pair "J16_SIO12-"
XMC Site 1 Rear I/O Differential Pair "J16_SIO13+"
XMC Site 1 Rear I/O Differential Pair "J16_SIO13-"
XMC Site 1 Rear I/O Differential Pair "J16_SIO14+"
XMC Site 1 Rear I/O Differential Pair "J16_SIO14-"
XMC Site 1 Rear I/O Differential Pair "J16_SIO15+"
XMC Site 1 Rear I/O Differential Pair "J16_SIO15-"
XMC Site 1 Rear I/O Differential Pair "J16_SIO16+"
XMC Site 1 Rear I/O Differential Pair "J16_SIO16-"
XMC Site 1 Rear I/O Differential Pair "J16_SIO17+"
XMC Site 1 Rear I/O Differential Pair "J16_SIO17-"
XMC Site 1 Rear I/O Differential Pair "J16_SIO18+"
XMC Site 1 Rear I/O Differential Pair "J16_SIO18-"
Acromag, Inc. Tel: 248-295-0310
- 52 -
SEARAY
Pin
E12
E13
D6
D5
E3
E2
E4
E5
J7
J8
G3
G4
H18
H17
J3
J4
D9
D10
E10
E11
F13
F14
H9
H10
D13
D14
E14
E15
K13
K14
E16
E17
D17
D18
E18
E19
K17
K18
www.acromag.com
ACEX-FP-IO-0x User’s Manual
J16_DP00_P
J16_DP00_N
J16_DP01_P
J16_DP01_N
J16_DP02_P
J16_DP02_N
J16_DP03_P
J16_DP03_N
J16_DP04_P
J16_DP04_N
J16_DP05_P
J16_DP05_N
J16_DP06_P
J16_DP06_N
J16_DP07_P
J16_DP07_N
J16_DP08_P
J16_DP08_N
J16_DP09_P
J16_DP09_N
J16_DP10_P
J16_DP10_N
J16_DP11_P
J16_DP11_N
J16_DP12_P
J16_DP12_N
J16_DP13_P
J16_DP13_N
J16_DP14_P
J16_DP14_N
J16_DP15_P
J16_DP15_N
J16_DP16_P
J16_DP16_N
J16_DP17_P
J16_DP17_N
J16_DP18_P
J16_DP18_N
J16_DP19_P
J16_DP19_N
COM Express Front Panel for Ruggedized/Military Packaging
XMC Site 1 Rear I/O Differential Pair "J16_DP00+"
XMC Site 1 Rear I/O Differential Pair "J16_DP00-"
XMC Site 1 Rear I/O Differential Pair "J16_DP01+"
XMC Site 1 Rear I/O Differential Pair "J16_DP01-"
XMC Site 1 Rear I/O Differential Pair "J16_DP02+"
XMC Site 1 Rear I/O Differential Pair "J16_DP02-"
XMC Site 1 Rear I/O Differential Pair "J16_DP03+"
XMC Site 1 Rear I/O Differential Pair "J16_DP03-"
XMC Site 1 Rear I/O Differential Pair "J16_DP04+"
XMC Site 1 Rear I/O Differential Pair "J16_DP04-"
XMC Site 1 Rear I/O Differential Pair "J16_DP05+"
XMC Site 1 Rear I/O Differential Pair "J16_DP05-"
XMC Site 1 Rear I/O Differential Pair "J16_DP06+"
XMC Site 1 Rear I/O Differential Pair "J16_DP06-"
XMC Site 1 Rear I/O Differential Pair "J16_DP07+"
XMC Site 1 Rear I/O Differential Pair "J16_DP07-"
XMC Site 1 Rear I/O Differential Pair "J16_DP08+"
XMC Site 1 Rear I/O Differential Pair "J16_DP08-"
XMC Site 1 Rear I/O Differential Pair "J16_DP09+"
XMC Site 1 Rear I/O Differential Pair "J16_DP09-"
XMC Site 1 Rear I/O Differential Pair "J16_DP10+"
XMC Site 1 Rear I/O Differential Pair "J16_DP10-"
XMC Site 1 Rear I/O Differential Pair "J16_DP11+"
XMC Site 1 Rear I/O Differential Pair "J16_DP11-"
XMC Site 1 Rear I/O Differential Pair "J16_DP12+"
XMC Site 1 Rear I/O Differential Pair "J16_DP12-"
XMC Site 1 Rear I/O Differential Pair "J16_DP13+"
XMC Site 1 Rear I/O Differential Pair "J16_DP13-"
XMC Site 1 Rear I/O Differential Pair "J16_DP14+"
XMC Site 1 Rear I/O Differential Pair "J16_DP14-"
XMC Site 1 Rear I/O Differential Pair "J16_DP15+"
XMC Site 1 Rear I/O Differential Pair "J16_DP15-"
XMC Site 1 Rear I/O Differential Pair "J16_DP16+"
XMC Site 1 Rear I/O Differential Pair "J16_DP16-"
XMC Site 1 Rear I/O Differential Pair "J16_DP17+"
XMC Site 1 Rear I/O Differential Pair "J16_DP17-"
XMC Site 1 Rear I/O Differential Pair "J16_DP18+"
XMC Site 1 Rear I/O Differential Pair "J16_DP18-"
XMC Site 1 Rear I/O Differential Pair "J16_DP19+"
XMC Site 1 Rear I/O Differential Pair "J16_DP19-"
Acromag, Inc. Tel: 248-295-0310
- 53 -
F20
F19
G20
G19
F18
F17
J16
J15
H14
H13
G16
G15
J12
J11
F10
F9
G8
G7
G12
G11
K10
K9
F6
F5
J20
J19
H6
H5
K6
K5
H2
H1
E7
E6
F2
F1
K2
K1
E8
E9
www.acromag.com
ACEX-FP-IO-0x User’s Manual
COM Express Front Panel for Ruggedized/Military Packaging
LPC
Signal Name
LPC_AD0
LPC_AD1
LPC_AD2
LPC_AD3
LPC_FRAME#
LPC_DRQ0#
LPC_DRQ1#
LPC_SERIRQ
LPC_CLK
Description
LPC Multiplexed Address - Command and Data Bus 0
LPC Multiplexed Address - Command and Data Bus 1
LPC Multiplexed Address - Command and Data Bus 2
LPC Multiplexed Address - Command and Data Bus 3
LPC Frame Signal - LPC Cycle Start Indicator
LPC Serial DMA Request Signal 0
LPC Serial DMA Request Signal 1
LPC Serial Interrupt Signal
LPC Clock Output - 33MHz Nominal
SEARAY
Pin
E46
E45
F46
F45
E43
D42
D41
E42
F42
I2C
Signal Name
I2C_CLK
I2C_DAT
Description
General Purpose I2C Port Clock Output
General Purpose I2C Port Data I/O Line
SEARAY
Pin
E36
E35
Miscellaneous
Signal Name
SPKR
WDTO
FAN_PWM
FAN_TACH
Description
Audio Enunciator Output - PC Beep Signal
Watchdog Timer Output
CPU Fan Speed Control
CPU Fan Tach Input
SEARAY
Pin
C35
C1
A23
A22
Power and System Management
Signal Name
PWRBTN#
SYSRST#
PLT_RST#
SUS_STAT#
SLP_S3#
SLP_S4#
SLP_S5#
WAKE0#
WAKE1#
BATLOW#
Description
Power Button Input Signal
System Reset Signal
Platform Reset Signal
Imminent Suspend Operation Indicator - Notifies LPC Devices
Output Signal Indicating Suspend to RAM State
Output Signal Indicating Suspend to Disk State
Output Signal Indicating Soft Off State
PCI Express Wake Signal
General Purpose Wake Signal
Low Battery Indicator for External Battery
Acromag, Inc. Tel: 248-295-0310
- 54 -
SEARAY
Pin
F41
E1
A24
C37
D40
D39
D38
G22
G21
C36
www.acromag.com
ACEX-FP-IO-0x User’s Manual
COM Express Front Panel for Ruggedized/Military Packaging
Thermal Protection
Signal Name
COM_THRM#
THRMTRIP3#
Description
Off-Module Temp Sensor Input Signal Indicating Over-Temp Condition
Output Signal Indicating CPU Entered Thermal Shutdown
SEARAY
Pin
D35
C34
SM Bus
Signal Name
SMB_CLK
SMB_DATA
SMB_ALERT#
Description
System Management Bus Bidirectional Clock Line
System Management Bus Bidirectional Data Line
System Management Bus Alert Signal
SEARAY
Pin
E40
E39
E41
GPIO
Signal Name
GPI_0
GPI_1
GPI_2
GPI_3
GPO_0
GPO_1
GPO_2
GPO_3
SEARAY
Pin
D19
C20
B19
B20
B23
B24
E20
D20
Description
General Purpose Input 0
General Purpose Input 1
General Purpose Input 2
General Purpose Input 3
General Purpose Output 0
General Purpose Output 1
General Purpose Output 2
General Purpose Output 3
Acromag, Inc. Tel: 248-295-0310
- 55 -
www.acromag.com
ACEX-FP-IO-0x User’s Manual
COM Express Front Panel for Ruggedized/Military Packaging
#23, 130 Pin 38999 keyed-B, Peripheral connector pin out (front view)
Acromag, Inc. Tel: 248-295-0310
- 56 -
www.acromag.com
ACEX-FP-IO-0x User’s Manual
COM Express Front Panel for Ruggedized/Military Packaging
#23, 130 Pin 38999 keyed-A and C, I/O connector pin out (front view)
Acromag, Inc. Tel: 248-295-0310
- 57 -
www.acromag.com
ACEX-FP-IO-0x User’s Manual
COM Express Front Panel for Ruggedized/Military Packaging
38999 Crimping Tools
If a Mating Cable Connector Kit (5028-558, 5028-559, 5028-560, or 5028-561) is purchased, the following list of
tools will be needed to properly build the cable. These tools, as recommended by Amphenol, can be purchased
from Daniel’s Manufacturing Corporation at www.dmctools.com.
DMC Part #
AF8
TH163
AFM8
K286
DAK225-22
DRK225-22
Description
Crimp Tool for 12-size Pins
12 Gauge Turret-Head Crimp
Positioner
Miniature Crimp Tool for 23-size Pins
23-Size Crimp Positioner
23-Size Pin Installation Tool
23-Size Pin Removal Tool
Acromag, Inc. Tel: 248-295-0310
Military Part #
M22520/1-01
M22520/1-04
Notes
Only required for 5028-561
Only required for 5028-561
M22520/2-01
M22520/2-12
- 58 -
www.acromag.com
ACEX-FP-IO-0x User’s Manual
COM Express Front Panel for Ruggedized/Military Packaging
PCB Mechanical Drawings
Acromag, Inc. Tel: 248-295-0310
- 59 -
www.acromag.com
ACEX-FP-IO-0x User’s Manual
Acromag, Inc. Tel: 248-295-0310
COM Express Front Panel for Ruggedized/Military Packaging
- 60 -
www.acromag.com
ACEX-FP-IO-0x User’s Manual
COM Express Front Panel for Ruggedized/Military Packaging
Bill of Materials
The following Bill of Materials is only for the components listed on the Mechanical Drawings that have a fixed
location. This reference is for customers that plan to design their own custom front panel boards that will
mechanically fit in the ARCX 4000 enclosure.
Bill of Materials
Reference Description
J3
J4
J5
J6
500P
200P
J7 and J8
Power LED
STATUS LED
Size #23 38999 connector keyed-A
Size #23 38999 connector keyed-B
Size #23 38999 connector keyed-C
Size #12 38999 connector keyed-A
SEARAY 500 PIN CONNECTOR
SEARAY 200 PIN CONNECTOR
Header connector (for optional Power filter)
Main power indicator LED, Blue
System status LED, Multi-color
Manufacture
Manufacture P/N
Amphenol
Amphenol
Amphenol
Amphenol
Samtec
Samtec
Samtec
SunLED
Kingbright
2M805-005-07ZNU23-130SA
2M805-005-07ZNU23-130SB
2M805-005-07ZNU23-130SC
2M805-005-07ZNU12-201SA
SEAM-50-02.0-L-10-2-A-GP-K-TR
SEAM-20-02.0-L-10-2-A-GP-K-TR
HPF-04-01-T-S
XLCBD11W
WP3VEGW
Schematic
The schematic is available for download at http://www.acromag.com.
Acromag, Inc. Tel: 248-295-0310
- 61 -
www.acromag.com
ACEX-FP-IO-0x User’s Manual
COM Express Front Panel for Ruggedized/Military Packaging
Mezzanine Board Installation
The connectors used to attach the mezzanine modules to the front panel board are offset and keyed to
prevent incorrect installation. To install, align the four mounting holes with the attached standoffs on the front
panel board. Attach board with M2.5 x 6mm screws on the four mounting holes.
ACEX-FP-IO-02
ACEX-FP-IO-02 with ACEX-IO mezzanine boards installed on Site 1 and Site 2
Acromag, Inc. Tel: 248-295-0310
- 62 -
www.acromag.com
ACEX-FP-IO-0x User’s Manual
COM Express Front Panel for Ruggedized/Military Packaging
ACEX-FP-IO-01
ACEX-FP-IO-01 with ACEX-IO mezzanine board installed on Site 1
Acromag, Inc. Tel: 248-295-0310
- 63 -
www.acromag.com
ACEX-FP-IO-0x User’s Manual
COM Express Front Panel for Ruggedized/Military Packaging
Certificate of Volatility
Certificate of Volatility
Acromag Model
ACEX-FP-IO-01
ACEX-FP-IO-02
Manufacturer:
Acromag, Inc.
30765 Wixom Rd
Wixom, MI 48393
Volatile Memory
Does this product contain Volatile memory (i.e. Memory of whose contents are lost when power is removed)
□ Yes
■ No
Type (SRAM, SDRAM, etc.)
User Modifiable
Function:
Process to Sanitize:
Size:
□ Yes
□ No
Type (SRAM, SDRAM, etc.)
Size:
User Modifiable
Function:
Process to Sanitize:
□ Yes
□ No
Non-Volatile Memory
Does this product contain Non-Volatile memory (i.e. Memory of whose contents is retained when power is removed)
□ Yes
■ No
Type (EEPROM, Flash, etc.) Size:
User Modifiable
Function:
Process to Sanitize:
□ Yes
□ No
Type (EEPROM, Flash, etc.) Size:
User Modifiable
Function:
Process to Sanitize:
□ Yes
□ No
Type (EEPROM, Flash, etc.) Size:
User Modifiable
Function:
Process to Sanitize:
□ Yes
□ No
Other capabilities:
Does device contain media storage capabilities: □ Yes ■ No
If yes explain
Is this device capable of wireless transmission: □ Yes ■ No
If yes explain
Acromag Representative
Name:
Joseph Primeau
Title:
Dir. of Sales and Marketing
Acromag, Inc. Tel: 248-295-0310
Email:
[email protected]
- 64 -
Office Phone:
248-624-1541
Office Fax:
248-624-9234
www.acromag.com
ACEX-FP-IO-0x User’s Manual
COM Express Front Panel for Ruggedized/Military Packaging
Revision History
The following table shows the revision history for this document:
Release Date
Version
EGR/DOC
07 JAN 15
A
MDW/ARP
01 JUL 15
B
PDG/ARP
Acromag, Inc. Tel: 248-295-0310
Description of Revision
Initial Acromag release.
Added 5028-566 and 5028-567 cables to order information.
Reserved Pins 2 and 5 on J6 (Input power connector).
- 65 -
www.acromag.com