Download DH series
Transcript
DH series 08 EEH604 1 ■Variation Rated current [A] Rated Breaking capacity(kA sym.)/ Rated making current(kA peak) IEC EN AS [Ics=Icu] 800A Rated Voltage 690VAC 1600A 50/105 55/121 Rated Voltage 440VAC 65/143 80/176 1250A 2000A 2500A 3200A 65/143 4000A 75/165 85/187 85/187 100/220 100/220 : DH series : DH-H series : DH-P series ■Based Standards JIS C8372………………………………… Japanese Industrial Standards (New JIS C8201-2 is also supported) IEC60947-2……………………………… International Electrotechnical Commission EN60947-2……………………………… European Standard AS 3947-2………………………………… Australian Standard NEMA PUB NO.SG3…………………… National Electrical Manufactures Association ANSI C37.13……………………………… American National Standard Institute ■Certification and Authorization ASTA, UK………………………………… ASTA Certification Service NK, Japan………………………………… Nippon Kaiji Kyokai LR, UK…………………………………… Lloyd's Register of Shipping ABS, USA………………………………… American Bureau of Shipping GL, Germany……………………………… Germanischer Lloyd BV, France………………………………… Bureau Veritas CONTENTS 2 1. Features 3 2. Specifications and Ratings 6 Standard types 6 High breaking types 7 3. Type number nomenclature 8 4. Characteristics of overcurrent trip device 10 5. Dimensions 11 6. Wiring diagrams 14 7. Accessories 16 Features The ultimate in compactness and operational capability Geared toward the smallest depth in the world Direct connection of the isolating main contacts to the hinges of the fixed main contacts eliminates the need for intermediate conductors. Allowing the DH series ACBs have the world’s smallest depth resulting in space saving in switchboards. DH Series DB series More than twenty design patents have been registered for the DH series ACB. Saved Space The height and depth dimensions are identical in all sizes to 3200A. There are two common widths or frame size, from 800-2000A and from 2500-3200A for the standard series. The panel cutout size is the same for all types of DH series ACB, which makes it easy to arrange the ACBs in switchboards. Maximum power from minimum volume was central to the design specification. With a depth of 290mm for the fixed type and 345mm for draw-out, it is one of the smallest ACBs in the world. ACBs with front connections are available off-the-shelf. Front connections are especially suitable for smaller-depth switchboards 345 458 H: 460 D: 375 D: 345 W: 354 W: 460 W: 631 Standard type 800~2000A 2500~3200A 4000A High breaking type 1250~2000A 1600~3200A Increased accessibility from the front It enhances ease of installation, operation, and maintenance. The double insulated design ensures that most accessories can be safely and easily, installed by the user. Control, auxiliary and position switch terminals are mounted at the front on the ACB body for easy access. Due to the increased level of harmonics within the distribution network, the neutral phase is fully rated as standard. Connection to the control circuit Replacement of internal parts (Removing the front cover enables replacement of internal parts.) No extra arc space required, vertical stacking permitted The DH series ACB dissipates all arc energy within its unique “Double Break” arc chamber. The internal energy dissipation within the ACB allows the clearance distance of the ACB to nearby earthed metal to be zero. This will assist in minimizing switchboard height and costs. No extra arc space required Manual operation Breaker fixing bolt (optional) Draw-out operation 3 08 .A=JKHAI .A=JKHAI A high performance and reliability Very fast interruption by “Double Break” system The unique “Double Break” main contact system ensures extremely fast interruption of short circuit currents and substantially reduces main contact wear. The internally symmetrical “Double Break” structure allows reverse power connection. No clamp screws used for the main circuit contact units Isolating main contact There are no clamp screws or flexible leads in the main circuit contact units. This substantially enhances the durability of the main circuit contact units and improves the reliability in ON-OFF operation. Fixed main contact Moving main contact Main circuit contact units Enhanced selectivity L Long time delay S Short time delay I Instantaneous At Fuji we are so concerned about selectivity that all our protection relays have ‘LSI’ characteristics as standard. This provides an adjustable time delay on overload (L) and also the l2t ramp characteristic (S). As shown, these are essential to provide selectivity when grading with other protective devices such as downstream fuses and upstream relays. The standard ‘LSI’ curve provides more than five million combinations of unique time current characteristics. Zone selective interlocking is available to provide zero time delay selectivity. As the rated breaking capacity is identical to the rated short-time withstand current full selectivity can be achieved. Performance Type and rated current DH08 DH12 DH16 DH20 Rated breaking With INST trip function current (at AC440V) With ST delay trip function (Without INST trip/MCR functions) Rated short-time withstand current (for 1 sec.) 4 800A DH12H 1250A DH16H 1600A DH20H 2000A 65kA 1250A DH25 1600A DH30 2000A 80kA 2500A DH16P 3200A DH20P DH25P DH30P 85kA 1600A DH40 2000A 2500A 3200A 100kA 4000A 100kA For general feeder circuits (L-characteristic) For general feeder circuits (R-characteristic) For generator protection (S-characteristic) .A=JKHAI .A=JKHAI FUJI ACB provides positive protection for electric power systems. The Fuji ACB DH series is equipped with an RMS sensing over-current release (OCR) having a wide range of protection functions and capabilities. Optimum protective coordination Inverse Definite Minimum Time (I.D.M.T.) Why use a separate panel mounted protection relay when you can have all the benefits of I.D.M.T. protection integral to the ACB? Fuji ACB is available with a choice of flexible protection curves to assist in selectivity applications. S.I. Standard Inverse V.I. Very Inverse E.I. Extremely Inverse All these curves are user definable and comply with IEC 60255-3. Standard transformer and generator protection characteristics are also available. I 0,02 t It I 2 t=S.I. I 3 t=V.I. I 4 t=E.I. AGR-L Industrial & transformer protection AGR-S Generator protection AGR-R Characteristics to IEC 60255-3 Overload protection Adjustable from 40–100% of rated current. True r.m.s detection up to the 19th harmonic, a distant vision for the competition who rarely see past the 7th. Neutral protection for all those Triple-N harmonics, such as 3rd, 9th and 15th. Also in case we forgot to mention, a “thermal memory” as standard! Two channel pre-trip alarm function (S-characteristic) ✽1 This function can be used to monitor and switch on additional power backup to feed critical circuits. For example, the function can be set so that when a pre-trip alarm is activated, an emergency generator starts to ensure a constant supply. This feature is only available on some AGR21 OCR models with a generator “S” characteristic. N-phase protection function (optional) In 3-phase, 4-wire systems that contain harmonic distortion, the 3rd harmonic may cause large currents to flow through the neutral conductor. The N-phase protection function prevents the neutral conductor from sustaining damage or burnout due to these large currents. Available in all OCRs except for generator “S” characteristic types. Standard OCR with adjustment Enhanced OCR with adjustment dial Type AGR-11. dial Type AGR-21. Reverse power trip function (S-characteristic) ✽1 (The first-ever feature for ACBs) This feature provides additional protection when paralleling generators. The AGR21 OCR for generator protection with the reverse power trip function, negates the need for installation and wiring in an external reverse power relay. This feature is available using an AGR21 OCR with a generator “S” type characteristic only. Earth leakage trip function (L/R-characteristic) ✽1 Used in conjunction with an externally mounted Zero phase Current Transformer (ZCT), this function provides protection against leakage to earth of very small levels of current. Trip or alarm indication, and contact output is available to enhance the level of system protection. Available using general purpose L / R -characteristic AGR21 OCR. Adjustable undervoltage trip function UVT ✽1 Available as a fixed type, or with adjustable voltage pick up and an adjustable time delay. 3 Phase, Phase failure protection is also available. AGR11/21 OCR's. 08 Contact temperature monitoring function (optional) ✽2 This function monitors the temperature of the ACBs main contacts. An alarm indicates when the temperature exceeds 155°C. Continuous monitoring of the contact temperature provides valuable input for preventative and predictive maintenance programs. ✽1: Not available for standard OCRs, type AGR-11. ✽2: Available for type AGR-21 OCR only. 5 DH series standard types Specifications and ratings ■ Specifications, standard types Frame size 800A Basic type DH08 No. of poles * 2 Rated current (A) *1 3 IEC, EN, AS JIS NEMA, ANSI NK, LR, AB, GL, BV 1250A ■ 4 1600A ■ DH12 3 4 2000A ■ DH16 3 2500A ■ DH20 4 3 4 DH25 3 3200A ■ 4 DH30 3 4000A ■ 4 ■ DH40 3 4 800 800 800 800 1250 1250 1250 1250 1600 1600 1540 1600 2000 2000 2000 2000 2500 2500 2500 2500 3200 3200 3200 3200 4000 3700 3700 4000 Rated current of the neutral pole (A) 800 1250 1600 2000 2500 3200 4000 Rated primary current of overcurrent tripping device (ICT) (A) 200 400 800 400 800 1250 400 800 1250 1600 400 800 1250 1600 2000 2500 3200 4000 100 ≤_ In ≤_ 200 200 < In ≤_ 400 400 < In ≤_ 800 200 ≤_ In ≤_ 400 400 < In ≤_ 800 630 < In ≤_1250 200 ≤_ In ≤_ 400 400 < In ≤_ 800 630 < In ≤_1250 800 < In ≤_1600 200 ≤_ In ≤_ 400 1250 ≤_ In ≤_ 2500 1600 ≤_ In ≤_ 3200 2000 ≤_ In ≤_ 4000 400 < In ≤_ 800 630 < In ≤_1250 800 < In ≤_1600 1000< In ≤_ 2000 1000 1000 1000 For general feeder circuit use Rated primary current of overcurrent tripping device (In) (A) For generator protection use In: Generator rated current Rated insulation voltage (Ui) (V, 50/60Hz) *3 1000 Rated operational voltage (Ue)(V, 50/60Hz)* 4 690 690 690 ● ● ● 1000 690 690 ● ● ● 1000 690 ● ● ● 690 Fixed type P Draw-out type with cradle X Draw-out type with cradle and shutter Q ● ● ● Main circuit terminal connection horizontal Mass (kg) For draw-out type X 73 Rated breaking capacity (kA, sym.)/ Rated making current (kA, peak) IEC, EN, AS [ICS=ICU] 690V AC 440V 50/105 50/105 50/105 50/105 65/143 65/143 75/165 65/143 (500V) 65/143 (500V) 65/143 (500V) 65/143 (500V) 85/187 (500V) 85/187 (500V) 100/220 (500V) 86 ● ● ● 1000 ● ● ● – ● ● vertical 73 86 76 90 79 94 105 125 105 125 139 NEMA, ANS 600V AC 480V 240V 42/96.6 50/115 65/149.5 42/96.6 50/115 65/149.5 42/96.6 50/115 65/149.5 42/96.6 50/115 65/149.5 50/115 65/149.5 85/195.5 50/115 65/149.5 85/195.5 65/149.5 75/172.5 100/230 JIS 550V AC 460V 220V 50/105 65/143 65/143 50/105 65/143 65/143 50/105 65/143 65/143 50/105 65/143 65/143 65/143 85/195.5 85/195.5 65/143 85/195.5 85/195.5 75/165 100/230 100/230 600V DC *5 250V 40/40 40/40 40/40 40/40 40/40 40/40 40/40 40/40 40/40 40/40 40/40 40/40 40/40 40/40 NK 3-pole type only 690V AC 450V 50/115 50/115 50/115 50/115 65/153 65/153 75/179 65/153 (500V) 65/153 (500V) 65/153 (500V) 65/153 (500V) 85/201 (500V) 85/201 (500V) 100/245 (500V) LR, AB, GL, BV 3-pole type only 690V AC 450V 50/115 50/115 50/115 50/115 65/153 65/153 75/179 65/153 (500V) 65/153 (500V) 65/153 (500V) 65/153 (500V) 85/201 (500V) 85/201 (500V) 100/245 (500V) Rated impulse withstand voltage (Uimp) (kV) 12 12 12 12 12 12 12 1 sec. 65 3 sec. 50 65 50 65 50 65 50 85 65 85 65 100 85 Rated latching current (kA, rms ) 65 65 65 65 85 85 100 Total fault clearing time (s) 0.03 0.03 0.03 0.03 0.03 0.03 0.03 Spring charging time 10 Closing time 0.08 10 0.08 10 0.08 10 0.08 10 0.08 10 0.08 10 0.08 Rated short time withstand current (Icw) (kA, rms ) Closing time (s) max. Notes: ● Available – Not available Replace the mark in the type number by the pole number code ■ Replace the ■ mark in the type number by the installation code 1 * *2 *3 *4 *5 6 176 3-pole: 3 Fixed: P 4-pole: 4 Draw-out with cradle: X At ambient temperature of 40°C (or at ambient temperature of 45°C for marine use) The 2-pole ACBs are similar to 3-pole types except that the center pole contacts and conductor are omitted. 1000V AC applies to IEC60947-2 and JIS C8201-2. 690V AC applies to IEC60947-2 and JIS C8201-2. 3-pole in series should be applied. Draw-out with cradle and shutter: Q DH series high breaking types Specifications and ratings ■ Specifications and ratings, high breaking types Frame size 1250A Basic type DH12 No. of poles * 2 Rated current (A) *1 3 IEC, EN, AS JIS NEMA, ANSI NK, LR, AB, GL, BV 1600A ■H 4 2000A ■H DH16 3 4 1600A ■H DH20 3 4 2000A 3 2500A ■ P DH20 DH16 4 3 3200A ■ P DH25 4 3 ■P 4 ■P DH30 3 4 1250 1250 1250 1250 1600 1600 1600 1600 2000 2000 2000 2000 1600 1600 1600 1600 2000 2000 2000 2000 2500 2500 2500 2500 3200 3200 3200 3200 Rated current of the neutral pole (A) 1250 1600 2000 1600 2000 2500 3200 Rated primary current of overcurrent tripping device (ICT) (A) 200 400 800 1250 1600 2000 200 400 800 1250 1600 2000 2500 3200 100 ≤_ In ≤_ 200 200 < In ≤_ 400 400 < In ≤_ 800 630 < In ≤_1250 800 ≤_ In ≤_ 1600 1000 ≤_ In ≤_ 2000 100 ≤_ In ≤_ 200 1000 ≤_ In ≤_ 2000 1250 ≤_ In ≤_ 2500 1600 ≤_ In ≤_ 3200 200 < In ≤_ 400 400 < In ≤_ 800 630 < In ≤_1250 800 < In ≤_1600 For general feeder circuit use Rated primary current of overcurrent tripping device (In) (A) For generator protection use In: Generator rated current Rated insulation voltage (Ui) (V, 50/60Hz) *3 1000 Rated operational voltage (Ue)(V, 50/60Hz)* 4 1000 690 690 ● ● ● 1000 1000 690 690 1000 690 ● ● ● 1000 690 ● ● ● 690 Fixed type P Draw-out type with cradle X Draw-out type with cradle and shutter Q ● ● ● Main circuit terminal connection vertical Mass (kg) For draw-out type X 79 Rated breaking capacity (kA, sym.)/ Rated making current (kA, peak) IEC, EN, AS [ICS=ICU] 690V AC 440V 55/121 80/176 55/121 80/176 55/121 80/176 85/187 100/220 85/187 100/220 85/187 100/220 85/187 100/220 94 ● ● ● 1000 ● ● ● – ● ● vertical 79 94 79 94 105 125 105 125 105 125 105 125 NEMA, ANS 600V AC 480V 240V 42/96.6 65/149.5 80/184 42/96.6 65/149.5 80/184 42/96.6 65/149.5 80/184 50/115 80/184 100/230 50/115 80/184 100/230 50/115 80/184 100/230 50/115 80/184 100/230 JIS 550V AC 460V 220V 55/121 80/176 80/176 55/121 80/176 80/176 55/121 80/176 80/176 85/196 100/230 100/230 85/196 100/230 100/230 85/196 100/230 100/230 85/196 100/230 100/230 600V DC *5 250V 40/40 40/40 40/40 40/40 40/40 40/40 40/40 40/40 40/40 40/40 40/40 40/40 40/40 40/40 NK 3-pole type only 690V AC 450V 55/128 80/186 55/128 80/186 55/128 80/186 85/201 100/233 85/201 100/233 85/201 100/233 85/201 100/233 LR, AB, GL, BV 3-pole type only 690V AC 450V 55/128 80/186 55/128 80/186 55/128 80/186 85/201 100/233 85/201 100/233 85/201 100/233 85/201 100/233 12 12 12 12 12 12 12 1 sec. 80 3 sec. 55 80 55 80 50 100 75 100 75 100 75 100 75 65 65 65 85 85 85 85 Rated impulse withstand voltage (Uimp) (kV) Rated short time withstand current (Icw) (kA, rms ) Rated latching current (kA, rms ) Total fault clearing time (s) 0.03 0.03 0.03 0.03 0.03 0.03 0.03 Closing time Spring charging time (s) max. Closing time 10 0.08 10 0.08 10 0.08 10 0.08 10 0.08 10 0.08 10 0.08 Notes: ● Available – Not available Replace the mark in the type number by the pole number code ■ Replace the ■ mark in the type number by the installation code 1 * *2 *3 *4 *5 3-pole: 3 Fixed: P 4-pole: 4 Draw-out with cradle: X 08 Draw-out with cradle and shutter: Q At ambient temperature of 40°C (or at ambient temperature of 45°C for marine use) The 2-pole ACBs are similar to 3-pole types except that the center pole contacts and conductor are omitted. 1000V AC applies to IEC60947-2 and JIS C8201-2. 690V AC applies to IEC60947-2 and JIS C8201-2. 3-pole in series should be applied. 7 DH series Type number nomenclature ■ Type number nomenclature DH 08 3 X H - M 11LAL F ① Basic type ② Frame size 08: 12: 16: 20: 25: 30: 40: 800A 1250A 1600A 2000A 2500A 3200A 4000A ➂ Number of poles 3: 4: 3-pole 4-pole ➃ Installation P: X: Q: Fixed Draw-out with cradle Draw-out with cradle & shutter ➄ Interrupting capacity class Blank: Standard H: High P: Super High ➅ Closing mechanism T: Manual-spring M: Motor-spring ex.M = 100VDC: for motor 100 to 100VDC ⑦ Overcurrent release device 11LAL: Standard (LT, ST, INST/MCA) 11LGL: Std. Plus GF (For details, see page 9.) ⑧ Tripping device F: R1: R2: Shunt trip ex. F = 100VDC Undervoltage trip/Inst. Undervoltage trip/Time delay ⑨Detailed specifications Specify any additional requirements, such as overseas standards compliance, special environmental usage, or accessories, when ordering. Also clearly indicate the applicable standards, main circuit voltage, and breaking current. See the tables below. ex. IEC 440VAC 65kA Applied standard Ordering code IEC IEC EN EN AS AS NEMA NEMA ANSI ANSI Special environment specification Ordering code Tropical uses Tropical Extremely cold use Extremely cold storage -40°C operating -25°C Anti-corrosion treatment Anti-corrosion Optional accessories Auxiliary switch (7c) Auxiliary switch (10c) Auxiliary switch (7c) for general 4c, for low level circuits 3c Auxiliary switch (10c) for general 7c, for low level circuits 3c Control circuit screw terminal Open (off) padlock Automatic closing spring release device Continuously – rated shunt trip device Capacitor trip device Undervoltage (instantaneous) trip device Undervoltage (500ms time delay) trip device Control circuit safety shutter Position switches Test jumper Mis – insertion protection device Breaker fixing bolts Door interlock Key lock Key interlock Mechanical interlock Manual reset device IP55 cover Control circuit terminal cover Earthing device Arc barrier Door flange Ordering code Auxiliary switch (7c) Auxiliary switch (10c) Auxiliary switch 4c + 3c Auxiliary switch 7c + 3c Control circuit screw terminal Open (off) padlock Automatic closing spring release device AVR-1C AQR-1 AUR-1BS AUR-1BD Control circuit safety shutter ALR- P Test jumper Mis – insertion protection device Breaker fixing bolts Door interlock Key lock Key interlock Mechanical interlock Manual reset device IP55 cover Control circuit terminal cover Earthing device Arc barrier Door flange External accessories CT for neutral line 800 to 1600A frame CT for neutral line 2000 to 4000A frame Power transformer Lifter OCR checker 8 Ordering code CW80-40LS EC160-40LS TSE-40LS AWR-1 (DH08 to DH30), AWR-2 (DH08 to DH40) ANU-1 DH series Type number nomenclature ■ Combination of overcurrent tripping device and indicator Application and Type characteristic number Protection function Output indication N phase Contact Long time delay Pre-alarm Ground Earth Reverse Under 1-contact Individual Spring Trip protection temperature Short time delay fault leakage power voltage for any trip contacts charge monitoring Instantaneous General L feeder protection 11LAL 11LGL 11LPS 11LPG ● ● ● ● ● ● 21LPS 21LPGU 21LPEL 21LPEM ● ● ● ● ● ● ● ● 11RAL 11RGL 11RPS 11RPG ● ● ● ● ● ● ● 21RPG ● ● ● 11SAL 11SPS ● ● ● 21SPSU 21SPRU 21STRU ● ● ● ● ● ● R Generator S protection Notes: ● ● ● ● ● ● ● ● ● ● ● ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ● ● ● ● ● ● ● ● ● ● ● ● ● ▲* ● ● ● ● ● ● ● ● ▲ ▲ ▲ ▲ ▲ ▲ ▲ ▲ ● ● ● ● ● ● ▲ * ● ● ▲ ▲ ▲ ▲ ● ● ▲* ▲* ▲* ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● Provided ▲ Optional Replace the mark in the type number by the following protective characteristic numbers (1 to 5). T: 1 IT: 2 I2T: 3 I3T: 4 I4T: 5 Either trip output indicator or undervoltage tripping device is available. 10.02 * ▲ When ordering the optional accessories, add the following codes to end of type number. Spring charge indicator: spring charge Trip indicator: trip N phase protection: N Contact temperature monitoring: O Over-current trip device type/code ✽1 ✽2 ex. AGR-11L-AL ✽1 AGR-11L-AL: Over current trip device only ✽2 11LAL: ACB with the overcurrent trip device 08 ■ Ordering information Specify the following: 1. Type number 2. Applied standard 3. Main circuit voltage and breaking capacity 4. Optional accessories for main device and OCR 5. Voltage of each device 6. External accessories 9 Air Circuit Breakers Multifunction overcurrent trip device Characteristics of overcurrent trip device For general feeder circuit/L-characteristic (Type AGR-11L, 21L) ■ Protection function Setting range Adj. long time delay LT Pick-up current IR (A) InX (0.8 — 0.85 — 0.9 — 0.95 — 1.0 — 1.05 — 1.1 — NON), 8 steps • NON-tripping at IR X 1.05 or less • Tripping between 1.05IR and 1.2IR Time delay TR (s) Tolerance of TR (%) (0.5 — 1.25 — 2.5 — 5 — 10 — 15 — 20 — 25 — 30) at 600% X IR, 9 steps ±15% +150ms -0ms Pickup current ISd (A) Tolerance of TSd (%) InX (1 — 1.5 — 2 — 2.5 — 3 — 4 — 6 — 8 — 10 — NON), 10 steps ±15% Time delay TSd (ms) Relay time (ms) Resettable time (ms) Total fault clearing time (ms) 50 25 120 Adj. instantaneous trip INST or MCR Pick-up current Ii (A) Tolerance (%) InX (2 — 4 — 6 — 8 — 10 — 12 — 14 — 16 — NON), 9 steps ±20% Adj. pre-trip alarm PTA Pick-up current IP1 (A) Tolerance of IP1 (%) Time delay TP1 (S) Tolerance of TP1 (%) In X (0.75 — 0.8 — 0.85 — 0.9 — 0.95 — 1.0), 6 steps ±7.5% (5 —10 — 15 — 20 — 40 — 60 — 80 — 120 — 160 — 200) at IP1 or more, 10 steps ±15% +100ms -0ms Adj. ground fault trip GF Pick-up current Ig (A) Tolerance of Ig (%) ICT X (0.1 — 0.2— 0.3 — 0.4 — 0.6 — 0.8 — 1.0— NON), 8 steps ±20% Time delay Tg (ms) Relay time (ms) Resettable time (ms) Total fault clearing time (ms) 100 75 170 Adj. short time delay ST Neutral phase protection function NP Adj. earth leakage trip ELT Undervoltage trip UVT (AGR21only) 100 75 170 200 175 270 200 175 270 300 275 370 400 375 470 500 475 570 600 575 670 800, 6steps 775 870 1000 975 1070 2000 , 6steps 1975 2070 Pick-up current IN (A) ICT X (0.4 — 0.5 — 0.63 — 0.8 — 1.0) Factory set to a user-specified value • Non-tripping at 1.05 IN or less • Tripping range: (1.05 to 1.2) IN Time delay TN (S) Tolerance of TN (%) Long time delay (LT) trip at 600% of IN ±15% +150ms -0ms Pick-up current I R (A) Current setting tolerance(%) 0.2 — 0.3 — 0.5 — 1.0 (Medium sensitivity) or 3 — 5 (Low sensitivity) • Non operate below 50% of I R, Operate between 50% and 100% of I Time delay t R (ms) Relay time (ms) Resettable time (ms) Max. total clearing time (ms) 100 50 250 Pick-up voltage (V) UVT rated supply voltage UC X (0.8 — 0.85 — 0.9 — 0.95), 4 steps Time delay time (S) 0 — 0.1 — 0.2 — 0.3 — 0.4 — 0.5 — 0.6 — 0.7 — 0.8 — 1.0, 10 steps Control power 200 150 350 300 250 450 500 450 600 100 to 120VAC common 200 to 240VAC 1000 950 1150 R 2000 , 6 steps 1950 2150 100 to 125VDC common 200 to 250VDC 24VDC common 48VDC Power consumption: 5VA : Default setting ■ Values of [ICT] and [In] Applicable [ICT] (A) 200 DH08 400 800 400 DH12 800 1250 400 DH16 800 1250 1600 Type : Default setting 10 Rated current [In](A) [ICT] [ICT] [ICT] [ICT] X 0.5 X 0.63 X 0.8 X 1.0 100 125 160 200 200 250 320 400 400 500 630 800 200 250 320 400 400 500 630 800 630 800 1000 1250 200 250 320 400 400 500 630 800 630 800 1000 1250 800 1000 1250 1600 Type DH20 DH25 DH30 DH40 Applicable [ICT] (A) 400 800 1250 1600 2000 2500 3200 4000 Rated current [In](A) [ICT] [ICT] [ICT] [ICT] X 0.5 X 0.63 X 0.8 X 1.0 200 250 320 400 400 500 630 800 630 800 1000 1250 800 1000 1250 1600 1000 1250 1600 2000 1250 1600 2000 2500 1600 2000 2500 3200 2000 2500 3200 4000 Applicable [ICT] (A) 200 DH12-H 400 800 1250 1600 DH16-H 2000 DH20-H 200 DH16-P 400 800 1250 1600 2000 DH20-P 2500 DH25-P 3200 DH30-P Type Rated current [In](A) [ICT] [ICT] [ICT] [ICT] X 0.5 X 0.63 X 0.8 X 1.0 100 125 160 200 200 250 320 400 400 500 630 800 630 800 1000 1250 800 1000 1250 1600 1000 1250 1600 2000 100 125 160 200 200 250 320 400 400 500 630 800 630 800 1000 1250 800 1000 1250 1600 1000 1250 1600 2000 1250 1600 2000 2500 1600 2000 2500 3200 DH series Dimensions Dimensions, mm • Fixed types DH08, DH12, DH16, DH20 DH12-H, DH16-H, DH20-H ■ 35 550 15.5 25 250 3-ø11 118 Maintenance space Vertical terminals Horizontal terminals Mounting holes 100 335 149 150.5 25 25 138 165 365 4-ø14 Mounting holes 165(3P) 250(4P) t2 174 82 82 165 165 Front panel cut 20(max) With UVT Controller 180(3P) 265(4P) 240(3P) 325(4P) 30 238 180 15 t1 232 460 490 550 (Arc space) 33 76 329 N P C 35 Arc barrier Lifting hole 81 240 2-ø11 165 14.5 14.5 194 102 15.5 25 17 Arc barrier 18 P 175 C 175(3P) 260(4P) Conductor overlap max. 25 52 15 Panel cutout Main circut terminal size (t1,t2: thickness p1,p2: interphase pitch) Horizontal terminals Vertical terminals p1 Type t1 Type t2 p2 85 DH08 10 DH20 15 85 85 DH12 10 DH12H 15 85 85 DH16 20 DH16H 15 85 DH20H 15 85 • Draw-out types DH08, DH12, DH16, DH20 DH12-H, DH16-H, DH20-H 81 08 177 177(3P) 262(4P) 204(3P) 289(4P) 240(3P) 325(4P) draw-out handle Maintenance space 9 265 94 141 345 385 120 120(3P) 205(4P) 149 15.5 25 25 150.5 14.514.5 25 25 40 Vertical terminals P C Horizontal terminals Rear panel cut 400 Main circut terminal size (t1,t2: thickness p1,p2: interphase pitch) Horizontal terminals Vertical terminals p1 Type t1 Type t2 p2 85 DH08 10 DH20 15 85 85 DH12 10 DH12H 15 85 85 DH16 20 DH16H 15 85 DH20H 15 85 Front panel cut BL 25 141 Mounting holes 4-ø14 Mounting holes 15.5 138 110 94 240 3-ø11 With UVT Controller 238 204 Maintenance space BL 335 42.5 140 Panel cutout 30 For fitted with breaker fixing bolts t2 174 329 460 490 500 9 33 16 232 12 50 R1 t1 N 18 78 25 158.5 52 P C CONNECTED position Control circuit terminal cover (optional) TEST position 35 2-ø20 Conductor overlap max. ISOLATED position Liftin 15 Maintenance 14 21 space hole 35 194 17 15 ON-OFF 30 button cover 2-ø11 250 164 164(3P) 249(4P) 11 DH series Dimensions Dimensions, mm • Fixed types DH25, DH30 DH16-P, DH20-P, DH25-P, DH30-P ■ Arc barrier Conductor overlap max. 12.5 33 76 With UVT Controller 238 165 217.5 165 365 550 250 4-ø11 20(max) 118 M8 screw earth terminal Maintenance space Vertical terminals 82 233(3P) 353(4P) 82 335 t1 Front panel cut 12.512.5 12.5 25 25 25 25 120 100 550 (Arc space) 232 460 490 N 329 15 Lifting hole 81 233 293(3P) 413(4P) 293 35 Panel cutout Main circut terminal size (t1: thickness p1: interphase pitch) Vertical terminals p1 Type t1 DH25 20 130 DH30 20 130 DH16P 20 130 DH20P 20 130 DH25P 20 130 DH30P 20 130 Mounting holes 4-ø14 Mounting holes 217.5(3P) 337.5(4P) 100 194 102 165 30 17 Arc barrier 228(3P) 348(4P) 25 25 165 P C 18 228 • Draw-out types DH25, DH30 DH16-P, DH20-P, DH25-P, DH30-P N 232 t1 140 With UVT Controller draw-out handle 238 Maintenance space 4-ø14 Mounting holes 172.5 12 172.5(3P) 110 4-ø11 40 P C Vertical terminals Rear panel cut Main circut terminal size (t1: thickness p1: interphase pitch) Vertical terminals p1 Type t1 DH25 20 130 DH30 20 130 DH16P 20 130 DH20P 20 130 DH25P 20 130 DH30P 20 130 335 141 Mounting holes 9 265 141 345 385 Front panel cut BL Panel cutout 30 293 230(3P) 350(4P) 257(3P) 377(4P) 293(3P) 413(4P) 94 400 230 257 94 Maintenance space 60 25 For fitted with breaker fixing bolts 33 12.5 16 9 490 500 329 460 12 50 R1 18 78 211.5 12.512.5 12.5 25 25 25 25 25 25 100 165 120 100 P C Control circuit CONNECTED position terminal cover (optional) TEST position 2-ø20 Conductor overlap max. ISOLATED position Liftin 21 Maintenance 14 81 space hole 35 17 194 15 ON-OFF 30 button cover 250 216 216(3P) 336(4P) DH series Dimensions Dimensions, mm • Draw-out types DH40 ■ ISOLATED position 21 14 ON-OFF button cover 42.5 draw-out handle 238 177 204 240 481(3P) 651(4P) 12.512.5 232 12.5 30 BL 4-ø11 With UVT Controller 9 454(3P) 624(4P) 375 428 295 35 P C 517(3P) 687(4P) Rear panel cut 335 141 Mounting holes 400 94 Maintenance space 140 33 For fitted with breaker fixing bolts 17 50 16 18 12 329 460 490 500 R1 40(Conductor overlap max.) 20 78 N 15 50 2-ø20 Liftin hole 194 15 Maintenance space 12.5 81 435.5(3P) 605.5(4P) 25 25 25 25 25 25 100 165 120 100 P C 181 Control circuit terminal cover CONNECTED position TEST position Front panel cut 4-ø14 Mounting holes 120 250 164 25 397(3P) 567(4P) 30 BL 441(3P) 611(4P) Panel cutout 08 13 DH series Wiring diagrams (with AGR-11 OCR or without OCR) ■ DH series Wiring diagrams Wiring diagrams 4 CT for neutral line Main circuit Control power Operation (+) (+) Motor charging/ Operation circuit Continuously-rated shunt trip (+) 1 ON switch (+) Position switches Fixed type UVT Common Auxiliary switches PB 3 PB AUX. SW Standard equipment Optional 4c 01 11 S1 S3 CT1 CT3 05 02 12 03 10 09 08 18 28 24 30 151 141 131 121 111 211 Optional 3c 311 411 511 611 3c 711 811 911 011 UVT control circuit Over-current release (type AGR-11 OCR) Ry LRC SHT 2 M S2 CT2 MHT UVT 19 29 K 21 k CT for neutral line ( ) L 15 25 06 16 26 17 27 X X X X X X 22 20 ( ) ( ) 154 152 144 142 134 132 124 122 114 112 214 212 314 312 414 412 514 512 614 612 714 712 814 812 914 912 014 012 X 08 For single-contact indication only 05 and 15 i Terminal description Check OCR voltage before connecting 01 21 Control power supply AC200 - 240V,DC200 - 250V,DC48V 01 11 Control power supply AC100 - 120V 11 21 Control power supply DC100 -125V,DC24V 02 22 Control power supply AC10 - 240V,DC100 - 220V,DC24V,DC48V 12 Operation switch,common 03 ON switch 05 Operation indication terminal,common 15 LT trip indication or single-contact indication 25 St/INST trip indication 06 PTA indication 16 GF trip indication 26 System alarm indication 17 trip indication 27 Spring charge indication 10 20 Cotinuously-rated shun trip 19 Separate CT for neutral line (k) 29 Separate CT for neutral line ( ) 08 ,18 , 28 UVT power supply 09 UVT power supply common UVT power supply Terminal 100V AC 200V AC No. coil coil 100V 200V 08 - 09 110V 220V 18 - 09 28 - 09 120V 240V Symbols for accessories CT1 - CT3 : Power CTs S1 - S3 : Current sensors M : Charging motor LRC : Latch release coil MHT : Magnetic Hold Trigger Isolating terminal connector (for draw-out type) Manual connector User wiring X Relay or indicator lamp 14 1 : Do not connected ˝b˝ contact of auxiliary switch to ON switch in series, otherwise, pumping may occur. 2 : Wiring diagrams changes for capacitor trip. 3 : Use ˝a˝ contact of auxiliary switch of ACB. 4 : For motor split circuit, terminals 02 , 22 and 03 , 04 are used for charging operation respectively. 400V AC coil 380V 415V 440V Position switches Top 151 141 131 121 Middle 154 144 134 124 Bottom 152 142 132 122 ( 4c arrangement) Top 131 121 Middle 134 124 Bottom 132 122 ( 2c arrangement) Operation/control circuits 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Auxiliary switches 111 211 311 411 511 611 711 811 911 011 114 214 314 414 514 614 714 814 914 014 112 212 312 412 512 612 712 812 912 012 (Standard 4c + optional 6c arrangement) 111 211 311 411 114 214 314 414 112 212 312 412 (Standard 4c arrangement) Designation of terminals for auxiliary and position switches 1: Common, 2: b-contact, 4: a-contact 1: Auxiliary switch 2: Position switch (for CONNECTED) 3: Position switch (for TEST) 4: Position switch (for ISOLATED) 5: Position switch (for INSERT) numbers ( 1A,–B,0:C:Switch Auxiliary switches for microload CONNECTED position : 121–124 ON 121–122 OFF TEST position : 131–134 ON 131–132 OFF ISOLATED position : 141–144 ON 141–142 OFF INSERT position : 151–154 ON 151–152 OFF 15 ■ Accessories Supplied accessories Position switch • Position switch ratings Auxiliary switch (4c) ON - OFF operation counter Indicator cover Lifting hole (Draw-out type) Lifting plate (Draw-out type) Voltage AC 100-250V DC 250V DC 125V DC 30V DC 8V Optional accessories • Auxiliary switch (Rated) Category Voltage 100 to 250VAC 251 to 500VAC 30VDC 125 to 250VDC For general service Resistive Inductive load (A) load (A) AC: cos ø ≥ 0.3 DC: L/R ≤ 0.01 5 5 5 5 1 1 1 1 For microload Resistive load (A) 0.1 – 0.1 – Type Inductive load (A) AC: cos ø ≥ 0.6 DC: L/R ≤ 0.007 0.1 – 0.1 – Min. applicable load 5VDC 1mA Notes: The chattering of b-contacts due to ON - OFF operation of the ACB lasts for less than 20ms. Do not supply different voltages to contacts of switch. • Capacitor trip switch Item Type Rated voltage Operational voltage Rated frequency Rated voltage of shunt trip used Power consumption ■ Contact ratings for operation indications (for AGR-11, 21) Voltage (V) AC 250 DC 250 125 30 Current (A) Single contact Individual contacts Resistive load Inductive load Resistive load Inductive load 8 3 0.5 0.2 0.3 0.15 0.27 0.04 0.5 0.25 0.5 0.2 5 3 2 0.7 Specifications AQR-1 100 to 120VAC Rated voltage X 70 to 110% 50/60Hz 480VDC 100VA ■ Contact ratings of Trip indicator for use with AGR-11or without OCR Voltage (V) AC 250 DC 250 125 30 Switch contact ratings (A) Inductive load Resistive load 3 6 0.1 0.1 0.5 0.5 3 3 ALR-0110P ALR-0101P ALR-0011P ALR-0200P ALR-0020P ALR-0002P ALR-1111P ALR-1210P ALR-1201P ALR-0211P ALR-1120P ALR-1021P ALR-0121P ALR-1102P ALR-1012P ALR-0112P ALR-0220P ALR-0202P ALR-0022P ALR-1030P ALR-0130P ALR-0031P ALR-1003P ALR-0103P ALR-0013P ALR-0040P ALR-0004P Resistive load (A) 11 0.3 0.6 6 10 Inductive load (A) (cos ø = 0.6, L/R = 0.07) 6 0.3 0.6 5 6 Number of Contact arrangement contacts INSERT ISOLATED TEST CONN 2c 4c 0 0 0 0 0 0 1 1 1 0 -1 1 0 1 1 0 0 0 0 1 0 0 1 0 0 0 0 1 1 0 2 0 0 1 2 2 2 1 0 1 1 0 1 2 2 0 0 1 0 0 1 0 0 0 1 0 1 0 2 0 1 1 0 1 2 2 2 0 1 1 2 0 2 3 3 3 0 0 1 4 0 0 1 1 0 0 2 1 0 1 1 0 1 1 2 2 2 0 2 2 0 0 1 3 3 3 0 4 Safety Considerations For safe operation, before using the product read the instruction manual or user manual that comes with the product carefully or consult the Fuji sales representative from which you purchased the product. ● Products introduced in this catalog have not been designed or manufactured for such applications in a system or equipment that will affect human bodies or lives. ● Customers, who want to use the products introduced in this catalog for special systems or devices such as for atomic-energy control, aerospace use, medical use, passenger vehicle, and traffic control, are requested to consult the Fuji sales division. ● Customers are requested to prepare safety measures when they apply the products introduced in this catalog to such systems or facilities that will affect human lives or cause severe damage to property if the products become faulty. ● For safe operation, wiring should be conducted only by qualified engineers who have sufficient technical knowledge about electrical work or wiring. ● Gate City Ohsaki, East Tower 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo, 141-0032, Japan Phone: +81-3-5435-7135~8 Fax: +81-3-5435-7456~9 URL http://www.fujielectric.co.jp/fcs/eng Printed on 100% recycled paper using soy-based ink Information in this catalog is subject to change without notice. 16 Printed in Japan 2004-2 L30 FIS