Download DH series

Transcript
DH series
08
EEH604
1
■Variation
Rated current [A]
Rated Breaking capacity(kA sym.)/
Rated making current(kA peak)
IEC EN AS
[Ics=Icu]
800A
Rated Voltage
690VAC
1600A
50/105
55/121
Rated Voltage
440VAC
65/143
80/176
1250A
2000A
2500A
3200A
65/143
4000A
75/165
85/187
85/187
100/220
100/220
: DH series
: DH-H series
: DH-P series
■Based Standards
JIS C8372………………………………… Japanese Industrial Standards
(New JIS C8201-2 is also supported)
IEC60947-2……………………………… International Electrotechnical Commission
EN60947-2……………………………… European Standard
AS 3947-2………………………………… Australian Standard
NEMA PUB NO.SG3…………………… National Electrical Manufactures Association
ANSI C37.13……………………………… American National Standard Institute
■Certification and Authorization
ASTA, UK………………………………… ASTA Certification Service
NK, Japan………………………………… Nippon Kaiji Kyokai
LR, UK…………………………………… Lloyd's Register of Shipping
ABS, USA………………………………… American Bureau of Shipping
GL, Germany……………………………… Germanischer Lloyd
BV, France………………………………… Bureau Veritas
CONTENTS
2
1. Features
3
2. Specifications and Ratings
6
Standard types
6
High breaking types
7
3. Type number nomenclature
8
4. Characteristics of overcurrent trip device
10
5. Dimensions
11
6. Wiring diagrams
14
7. Accessories
16
Features
The ultimate in compactness and operational capability
Geared toward the smallest depth in the world
Direct connection of the isolating main contacts to the hinges of the fixed main contacts
eliminates the need for intermediate conductors. Allowing the DH series ACBs have the
world’s smallest depth resulting in space saving in switchboards.
DH Series
DB series
More than twenty design patents have been registered for the DH series ACB.
Saved Space
The height and depth dimensions are identical in all sizes to 3200A. There are two common
widths or frame size, from 800-2000A and from 2500-3200A for the standard series. The
panel cutout size is the same for all types of DH series ACB, which makes it easy to arrange
the ACBs in switchboards.
Maximum power from minimum volume was central to the design specification. With a depth
of 290mm for the fixed type and 345mm for draw-out, it is one of the smallest ACBs in the
world.
ACBs with front connections are available off-the-shelf.
Front connections are especially suitable for smaller-depth switchboards
345
458
H: 460
D: 375
D: 345
W: 354
W: 460
W: 631
Standard type
800~2000A
2500~3200A
4000A
High breaking type
1250~2000A
1600~3200A
Increased accessibility from the front
It enhances ease of installation, operation, and maintenance.
The double insulated design ensures that most accessories can be safely and easily,
installed by the user. Control, auxiliary and position switch terminals are mounted at the
front on the ACB body for easy access. Due to the increased level of harmonics within the
distribution network, the neutral phase is fully rated as standard.
Connection to the
control circuit
Replacement of
internal parts
(Removing the front cover
enables replacement of
internal parts.)
No extra arc space required,
vertical stacking permitted
The DH series ACB dissipates all arc energy
within its unique “Double Break” arc chamber.
The internal energy dissipation within the ACB
allows the clearance distance of the ACB to
nearby earthed metal to be zero. This will assist
in minimizing switchboard height and costs.
No extra arc space
required
Manual operation
Breaker fixing bolt
(optional)
Draw-out operation
3
08
.A=JKHAI
.A=JKHAI
A high performance and reliability
Very fast interruption by
“Double Break” system
The unique “Double Break” main contact system ensures
extremely fast interruption of short circuit currents and substantially
reduces main contact wear. The internally symmetrical
“Double Break” structure allows reverse power connection.
No clamp screws used for the main circuit
contact units
Isolating main contact
There are no clamp screws or flexible leads in the main circuit
contact units.
This substantially enhances the durability of the main circuit contact
units and improves the reliability in ON-OFF operation.
Fixed main contact
Moving main contact
Main circuit contact units
Enhanced selectivity
L Long time delay
S Short time delay
I Instantaneous
At Fuji we are so concerned about selectivity that all our
protection relays have ‘LSI’ characteristics as standard.
This provides an adjustable time delay on overload (L) and also the
l2t ramp characteristic (S).
As shown, these are essential to provide selectivity when grading
with other protective devices such as downstream fuses and
upstream relays.
The standard ‘LSI’ curve provides more than five million
combinations of unique time current characteristics.
Zone selective interlocking is available to provide zero time delay
selectivity.
As the rated breaking capacity is identical to the rated short-time
withstand current full selectivity can be achieved.
Performance
Type and rated current DH08
DH12
DH16
DH20
Rated breaking With INST trip function
current
(at AC440V)
With ST delay trip function
(Without INST trip/MCR functions)
Rated short-time withstand current (for 1 sec.)
4
800A DH12H
1250A DH16H
1600A DH20H
2000A
65kA
1250A DH25
1600A DH30
2000A
80kA
2500A DH16P
3200A DH20P
DH25P
DH30P
85kA
1600A DH40
2000A
2500A
3200A
100kA
4000A
100kA
For general feeder circuits (L-characteristic)
For general feeder circuits (R-characteristic)
For generator protection (S-characteristic)
.A=JKHAI
.A=JKHAI
FUJI ACB provides positive protection for
electric power systems.
The Fuji ACB DH series is equipped with an RMS sensing over-current
release (OCR) having a wide range of protection functions and capabilities.
Optimum protective
coordination
Inverse Definite Minimum Time (I.D.M.T.)
Why use a separate panel mounted protection
relay when you can have all the benefits of
I.D.M.T. protection integral to the ACB?
Fuji ACB is available with a choice of flexible
protection curves to assist in selectivity
applications.
S.I. Standard Inverse
V.I. Very Inverse
E.I. Extremely Inverse
All these curves are user definable and comply
with IEC 60255-3. Standard transformer and
generator protection characteristics are also
available.
I 0,02 t
It
I 2 t=S.I.
I 3 t=V.I.
I 4 t=E.I.
AGR-L Industrial & transformer protection
AGR-S Generator protection
AGR-R Characteristics to IEC 60255-3
Overload protection
Adjustable from 40–100% of rated current.
True r.m.s detection up to the 19th harmonic, a
distant vision for the competition who rarely
see past the 7th. Neutral protection for all
those Triple-N harmonics, such as 3rd, 9th and
15th. Also in case we forgot to mention, a
“thermal memory” as standard!
Two channel pre-trip alarm function
(S-characteristic) ✽1
This function can be used to monitor and
switch on additional power backup to feed
critical circuits. For example, the function can
be set so that when a pre-trip alarm is
activated, an emergency generator starts to
ensure a constant supply. This feature is only
available on some AGR21 OCR models with a
generator “S” characteristic.
N-phase protection function (optional)
In 3-phase, 4-wire systems that contain
harmonic distortion, the 3rd harmonic may
cause large currents to flow through the
neutral conductor. The N-phase protection
function prevents the neutral conductor from
sustaining damage or burnout due to these
large currents. Available in all OCRs except for
generator “S” characteristic types.
Standard OCR with adjustment Enhanced OCR with adjustment
dial Type AGR-11.
dial Type AGR-21.
Reverse power trip function
(S-characteristic) ✽1
(The first-ever feature for ACBs)
This feature provides additional protection
when paralleling generators. The AGR21 OCR
for generator protection with the reverse power
trip function, negates the need for installation
and wiring in an external reverse power relay.
This feature is available using an AGR21 OCR
with a generator “S” type characteristic only.
Earth leakage trip function
(L/R-characteristic) ✽1
Used in conjunction with an externally
mounted Zero phase Current Transformer
(ZCT), this function provides protection against
leakage to earth of very small levels of current.
Trip or alarm indication, and contact output is
available to enhance the level of system
protection. Available using general purpose L /
R -characteristic AGR21 OCR.
Adjustable undervoltage
trip function UVT ✽1
Available as a fixed type, or with adjustable
voltage pick up and an adjustable time delay. 3
Phase, Phase failure protection is also
available. AGR11/21 OCR's.
08
Contact temperature
monitoring function (optional) ✽2
This function monitors the temperature of the
ACBs main contacts. An alarm indicates when
the temperature exceeds 155°C. Continuous
monitoring of the contact temperature provides
valuable input for preventative and predictive
maintenance programs.
✽1: Not available for standard OCRs, type AGR-11.
✽2: Available for type AGR-21 OCR only.
5
DH series standard types
Specifications and ratings
■ Specifications, standard types
Frame size
800A
Basic type
DH08
No. of poles *
2
Rated current (A) *1
3
IEC, EN, AS
JIS
NEMA, ANSI
NK, LR, AB, GL, BV
1250A
■
4
1600A
■
DH12
3
4
2000A
■
DH16
3
2500A
■
DH20
4
3
4
DH25
3
3200A
■
4
DH30
3
4000A
■
4
■
DH40
3
4
800
800
800
800
1250
1250
1250
1250
1600
1600
1540
1600
2000
2000
2000
2000
2500
2500
2500
2500
3200
3200
3200
3200
4000
3700
3700
4000
Rated current of the neutral pole (A)
800
1250
1600
2000
2500
3200
4000
Rated primary current of
overcurrent tripping device (ICT) (A)
200
400
800
400
800
1250
400
800
1250
1600
400
800
1250
1600
2000
2500
3200
4000
100 ≤_ In ≤_ 200
200 < In ≤_ 400
400 < In ≤_ 800
200 ≤_ In ≤_ 400
400 < In ≤_ 800
630 < In ≤_1250
200 ≤_ In ≤_ 400
400 < In ≤_ 800
630 < In ≤_1250
800 < In ≤_1600
200 ≤_ In ≤_ 400 1250 ≤_ In ≤_ 2500 1600 ≤_ In ≤_ 3200 2000 ≤_ In ≤_ 4000
400 < In ≤_ 800
630 < In ≤_1250
800 < In ≤_1600
1000< In ≤_ 2000
1000
1000
1000
For general feeder circuit use
Rated primary current of
overcurrent tripping device (In) (A)
For generator protection use
In: Generator rated current
Rated insulation voltage (Ui) (V, 50/60Hz) *3 1000
Rated operational voltage (Ue)(V, 50/60Hz)*
4
690
690
690
●
●
●
1000
690
690
●
●
●
1000
690
●
●
●
690
Fixed type P
Draw-out type with cradle X
Draw-out type with cradle and shutter Q
●
●
●
Main circuit terminal connection
horizontal
Mass (kg) For draw-out type X
73
Rated breaking capacity (kA, sym.)/
Rated making current (kA, peak)
IEC, EN, AS [ICS=ICU]
690V AC
440V
50/105
50/105
50/105
50/105
65/143
65/143
75/165
65/143 (500V) 65/143 (500V) 65/143 (500V) 65/143 (500V) 85/187 (500V) 85/187 (500V) 100/220 (500V)
86
●
●
●
1000
●
●
●
–
●
●
vertical
73
86
76
90
79
94
105
125
105
125
139
NEMA, ANS
600V AC
480V
240V
42/96.6
50/115
65/149.5
42/96.6
50/115
65/149.5
42/96.6
50/115
65/149.5
42/96.6
50/115
65/149.5
50/115
65/149.5
85/195.5
50/115
65/149.5
85/195.5
65/149.5
75/172.5
100/230
JIS
550V AC
460V
220V
50/105
65/143
65/143
50/105
65/143
65/143
50/105
65/143
65/143
50/105
65/143
65/143
65/143
85/195.5
85/195.5
65/143
85/195.5
85/195.5
75/165
100/230
100/230
600V DC *5
250V
40/40
40/40
40/40
40/40
40/40
40/40
40/40
40/40
40/40
40/40
40/40
40/40
40/40
40/40
NK
3-pole type only
690V AC
450V
50/115
50/115
50/115
50/115
65/153
65/153
75/179
65/153 (500V) 65/153 (500V) 65/153 (500V) 65/153 (500V) 85/201 (500V) 85/201 (500V) 100/245 (500V)
LR, AB, GL, BV
3-pole type only
690V AC
450V
50/115
50/115
50/115
50/115
65/153
65/153
75/179
65/153 (500V) 65/153 (500V) 65/153 (500V) 65/153 (500V) 85/201 (500V) 85/201 (500V) 100/245 (500V)
Rated impulse withstand voltage (Uimp) (kV)
12
12
12
12
12
12
12
1 sec. 65
3 sec. 50
65
50
65
50
65
50
85
65
85
65
100
85
Rated latching current (kA, rms )
65
65
65
65
85
85
100
Total fault clearing time (s)
0.03
0.03
0.03
0.03
0.03
0.03
0.03
Spring charging time 10
Closing time
0.08
10
0.08
10
0.08
10
0.08
10
0.08
10
0.08
10
0.08
Rated short time withstand current
(Icw) (kA, rms )
Closing time
(s) max.
Notes: ● Available
– Not available
Replace the mark in the type number by the pole number code
■ Replace the ■ mark in the type number by the installation code
1
*
*2
*3
*4
*5
6
176
3-pole: 3
Fixed: P
4-pole: 4
Draw-out with cradle: X
At ambient temperature of 40°C (or at ambient temperature of 45°C for marine use)
The 2-pole ACBs are similar to 3-pole types except that the center pole contacts and conductor are omitted.
1000V AC applies to IEC60947-2 and JIS C8201-2.
690V AC applies to IEC60947-2 and JIS C8201-2.
3-pole in series should be applied.
Draw-out with cradle and shutter: Q
DH series high breaking types
Specifications and ratings
■ Specifications and ratings, high breaking types
Frame size
1250A
Basic type
DH12
No. of poles *
2
Rated current (A) *1
3
IEC, EN, AS
JIS
NEMA, ANSI
NK, LR, AB, GL, BV
1600A
■H
4
2000A
■H
DH16
3
4
1600A
■H
DH20
3
4
2000A
3
2500A
■ P DH20
DH16
4
3
3200A
■ P DH25
4
3
■P
4
■P
DH30
3
4
1250
1250
1250
1250
1600
1600
1600
1600
2000
2000
2000
2000
1600
1600
1600
1600
2000
2000
2000
2000
2500
2500
2500
2500
3200
3200
3200
3200
Rated current of the neutral pole (A)
1250
1600
2000
1600
2000
2500
3200
Rated primary current of
overcurrent tripping device (ICT) (A)
200
400
800
1250
1600
2000
200
400
800
1250
1600
2000
2500
3200
100 ≤_ In ≤_ 200
200 < In ≤_ 400
400 < In ≤_ 800
630 < In ≤_1250
800 ≤_ In ≤_ 1600 1000 ≤_ In ≤_ 2000 100 ≤_ In ≤_ 200 1000 ≤_ In ≤_ 2000 1250 ≤_ In ≤_ 2500 1600 ≤_ In ≤_ 3200
200 < In ≤_ 400
400 < In ≤_ 800
630 < In ≤_1250
800 < In ≤_1600
For general feeder circuit use
Rated primary current of
overcurrent tripping device (In) (A)
For generator protection use
In: Generator rated current
Rated insulation voltage (Ui) (V, 50/60Hz) *3 1000
Rated operational voltage (Ue)(V, 50/60Hz)*
4
1000
690
690
●
●
●
1000
1000
690
690
1000
690
●
●
●
1000
690
●
●
●
690
Fixed type P
Draw-out type with cradle X
Draw-out type with cradle and shutter Q
●
●
●
Main circuit terminal connection
vertical
Mass (kg) For draw-out type X
79
Rated breaking capacity (kA, sym.)/
Rated making current (kA, peak)
IEC, EN, AS [ICS=ICU]
690V AC
440V
55/121
80/176
55/121
80/176
55/121
80/176
85/187
100/220
85/187
100/220
85/187
100/220
85/187
100/220
94
●
●
●
1000
●
●
●
–
●
●
vertical
79
94
79
94
105
125
105
125
105
125
105
125
NEMA, ANS
600V AC
480V
240V
42/96.6
65/149.5
80/184
42/96.6
65/149.5
80/184
42/96.6
65/149.5
80/184
50/115
80/184
100/230
50/115
80/184
100/230
50/115
80/184
100/230
50/115
80/184
100/230
JIS
550V AC
460V
220V
55/121
80/176
80/176
55/121
80/176
80/176
55/121
80/176
80/176
85/196
100/230
100/230
85/196
100/230
100/230
85/196
100/230
100/230
85/196
100/230
100/230
600V DC *5
250V
40/40
40/40
40/40
40/40
40/40
40/40
40/40
40/40
40/40
40/40
40/40
40/40
40/40
40/40
NK
3-pole type only
690V AC
450V
55/128
80/186
55/128
80/186
55/128
80/186
85/201
100/233
85/201
100/233
85/201
100/233
85/201
100/233
LR, AB, GL, BV
3-pole type only
690V AC
450V
55/128
80/186
55/128
80/186
55/128
80/186
85/201
100/233
85/201
100/233
85/201
100/233
85/201
100/233
12
12
12
12
12
12
12
1 sec. 80
3 sec. 55
80
55
80
50
100
75
100
75
100
75
100
75
65
65
65
85
85
85
85
Rated impulse withstand voltage (Uimp) (kV)
Rated short time withstand current
(Icw) (kA, rms )
Rated latching current (kA, rms )
Total fault clearing time (s)
0.03
0.03
0.03
0.03
0.03
0.03
0.03
Closing time Spring charging time
(s) max.
Closing time
10
0.08
10
0.08
10
0.08
10
0.08
10
0.08
10
0.08
10
0.08
Notes: ● Available
– Not available
Replace the mark in the type number by the pole number code
■ Replace the ■ mark in the type number by the installation code
1
*
*2
*3
*4
*5
3-pole: 3
Fixed: P
4-pole: 4
Draw-out with cradle: X
08
Draw-out with cradle and shutter: Q
At ambient temperature of 40°C (or at ambient temperature of 45°C for marine use)
The 2-pole ACBs are similar to 3-pole types except that the center pole contacts and conductor are omitted.
1000V AC applies to IEC60947-2 and JIS C8201-2.
690V AC applies to IEC60947-2 and JIS C8201-2.
3-pole in series should be applied.
7
DH series
Type number nomenclature
■ Type number nomenclature
DH 08 3 X H - M 11LAL F
① Basic type
② Frame size
08:
12:
16:
20:
25:
30:
40:
800A
1250A
1600A
2000A
2500A
3200A
4000A
➂ Number of poles
3:
4:
3-pole
4-pole
➃ Installation
P:
X:
Q:
Fixed
Draw-out with cradle
Draw-out with cradle &
shutter
➄ Interrupting capacity class
Blank: Standard
H:
High
P:
Super High
➅ Closing mechanism
T:
Manual-spring
M:
Motor-spring
ex.M = 100VDC: for motor 100 to 100VDC
⑦ Overcurrent release device
11LAL: Standard (LT, ST, INST/MCA)
11LGL: Std. Plus GF
(For details, see page 9.)
⑧ Tripping device
F:
R1:
R2:
Shunt trip
ex. F = 100VDC
Undervoltage trip/Inst.
Undervoltage trip/Time delay
⑨Detailed specifications
Specify any additional requirements, such as overseas standards
compliance, special environmental usage, or accessories, when ordering.
Also clearly indicate the applicable standards, main circuit voltage,
and breaking current. See the tables below.
ex. IEC 440VAC 65kA
Applied standard
Ordering code
IEC
IEC
EN
EN
AS
AS
NEMA
NEMA
ANSI
ANSI
Special environment specification
Ordering code
Tropical uses
Tropical
Extremely cold use
Extremely cold
storage -40°C
operating -25°C
Anti-corrosion treatment Anti-corrosion
Optional accessories
Auxiliary switch (7c)
Auxiliary switch (10c)
Auxiliary switch (7c)
for general 4c, for low level circuits 3c
Auxiliary switch (10c)
for general 7c, for low level circuits 3c
Control circuit screw terminal
Open (off) padlock
Automatic closing spring release device
Continuously – rated shunt trip device
Capacitor trip device
Undervoltage (instantaneous) trip device
Undervoltage (500ms time delay) trip
device
Control circuit safety shutter
Position switches
Test jumper
Mis – insertion protection device
Breaker fixing bolts
Door interlock
Key lock
Key interlock
Mechanical interlock
Manual reset device
IP55 cover
Control circuit terminal cover
Earthing device
Arc barrier
Door flange
Ordering code
Auxiliary switch (7c)
Auxiliary switch (10c)
Auxiliary switch
4c + 3c
Auxiliary switch
7c + 3c
Control circuit screw terminal
Open (off) padlock
Automatic closing spring release device
AVR-1C
AQR-1
AUR-1BS
AUR-1BD
Control circuit safety shutter
ALR- P
Test jumper
Mis – insertion protection device
Breaker fixing bolts
Door interlock
Key lock
Key interlock
Mechanical interlock
Manual reset device
IP55 cover
Control circuit terminal cover
Earthing device
Arc barrier
Door flange
External accessories
CT for neutral line 800 to 1600A frame
CT for neutral line 2000 to 4000A frame
Power transformer
Lifter
OCR checker
8
Ordering code
CW80-40LS
EC160-40LS
TSE-40LS
AWR-1 (DH08 to DH30), AWR-2 (DH08 to DH40)
ANU-1
DH series
Type number nomenclature
■ Combination of overcurrent tripping device and indicator
Application and Type
characteristic
number
Protection function
Output indication
N phase Contact
Long time delay Pre-alarm Ground Earth
Reverse Under 1-contact Individual Spring Trip protection temperature
Short time delay
fault
leakage power voltage for any trip contacts charge
monitoring
Instantaneous
General
L
feeder
protection
11LAL
11LGL
11LPS
11LPG
●
●
●
●
●
●
21LPS
21LPGU
21LPEL
21LPEM
●
●
●
●
●
●
●
●
11RAL
11RGL
11RPS
11RPG
●
●
●
●
●
●
●
21RPG
●
●
●
11SAL
11SPS
●
●
●
21SPSU
21SPRU
21STRU
●
●
●
●
●
●
R
Generator S
protection
Notes: ●
●
●
●
●
●
●
●
●
●
●
▲
▲
▲
▲
▲
▲
▲
▲
●
●
●
●
●
●
●
●
●
●
●
●
●
▲*
●
●
●
●
●
●
●
●
▲
▲
▲
▲
▲
▲
▲
▲
●
●
●
●
●
●
▲ * ●
●
▲
▲
▲
▲
●
●
▲*
▲*
▲*
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Provided
▲ Optional
Replace the
mark in the type number by the following protective characteristic numbers (1 to 5).
T: 1
IT: 2
I2T: 3
I3T: 4
I4T: 5
Either trip output indicator or undervoltage tripping device is available.
10.02
*
▲ When ordering the optional accessories, add the following codes to end of type number.
Spring charge indicator: spring charge
Trip indicator: trip
N phase protection: N
Contact temperature monitoring: O
Over-current trip device type/code
✽1
✽2
ex. AGR-11L-AL
✽1 AGR-11L-AL: Over current trip device only
✽2 11LAL:
ACB with the overcurrent trip device
08
■ Ordering information
Specify the following:
1. Type number
2. Applied standard
3. Main circuit voltage and breaking capacity
4. Optional accessories for main device and OCR
5. Voltage of each device
6. External accessories
9
Air Circuit Breakers
Multifunction overcurrent trip device
Characteristics of overcurrent trip device
For general feeder circuit/L-characteristic (Type AGR-11L, 21L)
■
Protection
function
Setting range
Adj. long time
delay LT
Pick-up current IR (A)
InX (0.8 — 0.85 — 0.9 — 0.95 — 1.0 — 1.05 — 1.1 — NON), 8 steps
• NON-tripping at IR X 1.05 or less
• Tripping between 1.05IR and 1.2IR
Time delay TR (s)
Tolerance of TR (%)
(0.5 — 1.25 — 2.5 — 5 — 10 — 15 — 20 — 25 — 30) at 600% X IR, 9 steps
±15% +150ms -0ms
Pickup current ISd (A)
Tolerance of TSd (%)
InX (1 — 1.5 — 2 — 2.5 — 3 — 4 — 6 — 8 — 10 — NON), 10 steps
±15%
Time delay TSd (ms)
Relay time (ms)
Resettable time (ms)
Total fault clearing time (ms)
50
25
120
Adj. instantaneous
trip INST or MCR
Pick-up current Ii (A)
Tolerance (%)
InX (2 — 4 — 6 — 8 — 10 — 12 — 14 — 16 — NON), 9 steps
±20%
Adj. pre-trip
alarm PTA
Pick-up current IP1 (A)
Tolerance of IP1 (%)
Time delay TP1 (S)
Tolerance of TP1 (%)
In X (0.75 — 0.8 — 0.85 — 0.9 — 0.95 — 1.0), 6 steps
±7.5%
(5 —10 — 15 — 20 — 40 — 60 — 80 — 120 — 160 — 200) at IP1 or more, 10 steps
±15% +100ms -0ms
Adj. ground fault
trip GF
Pick-up current Ig (A)
Tolerance of Ig (%)
ICT X (0.1 — 0.2— 0.3 — 0.4 — 0.6 — 0.8 — 1.0— NON), 8 steps
±20%
Time delay Tg (ms)
Relay time (ms)
Resettable time (ms)
Total fault clearing time (ms)
100
75
170
Adj. short time
delay ST
Neutral phase
protection
function NP
Adj. earth leakage
trip ELT
Undervoltage trip
UVT (AGR21only)
100
75
170
200
175
270
200
175
270
300
275
370
400
375
470
500
475
570
600
575
670
800, 6steps
775
870
1000
975
1070
2000 , 6steps
1975
2070
Pick-up current IN (A)
ICT X (0.4 — 0.5 — 0.63 — 0.8 — 1.0) Factory set to a user-specified value
• Non-tripping at 1.05 IN or less • Tripping range: (1.05 to 1.2) IN
Time delay TN (S)
Tolerance of TN (%)
Long time delay (LT) trip at 600% of IN
±15% +150ms -0ms
Pick-up current I R (A)
Current setting tolerance(%)
0.2 — 0.3 — 0.5 — 1.0 (Medium sensitivity) or 3 — 5 (Low sensitivity)
• Non operate below 50% of I R, Operate between 50% and 100% of I
Time delay t R (ms)
Relay time (ms)
Resettable time (ms)
Max. total clearing time (ms)
100
50
250
Pick-up voltage (V)
UVT rated supply voltage UC X (0.8 — 0.85 — 0.9 — 0.95), 4 steps
Time delay time (S)
0 — 0.1 — 0.2 — 0.3 — 0.4 — 0.5 — 0.6 — 0.7 — 0.8 — 1.0, 10 steps
Control power
200
150
350
300
250
450
500
450
600
100 to 120VAC common
200 to 240VAC
1000
950
1150
R
2000 , 6 steps
1950
2150
100 to 125VDC common
200 to 250VDC
24VDC common
48VDC
Power consumption: 5VA
: Default setting
■
Values of [ICT] and [In]
Applicable
[ICT]
(A)
200
DH08
400
800
400
DH12
800
1250
400
DH16
800
1250
1600
Type
: Default setting
10
Rated current [In](A)
[ICT]
[ICT]
[ICT]
[ICT]
X 0.5 X 0.63 X 0.8 X 1.0
100
125
160
200
200
250
320
400
400
500
630
800
200
250
320
400
400
500
630
800
630
800
1000 1250
200
250
320
400
400
500
630
800
630
800
1000 1250
800
1000 1250 1600
Type
DH20
DH25
DH30
DH40
Applicable
[ICT]
(A)
400
800
1250
1600
2000
2500
3200
4000
Rated current [In](A)
[ICT]
[ICT]
[ICT]
[ICT]
X 0.5 X 0.63 X 0.8 X 1.0
200
250
320
400
400
500
630
800
630
800
1000 1250
800
1000 1250 1600
1000 1250 1600 2000
1250 1600 2000 2500
1600 2000 2500 3200
2000 2500 3200 4000
Applicable
[ICT]
(A)
200
DH12-H
400
800
1250
1600
DH16-H
2000
DH20-H
200
DH16-P
400
800
1250
1600
2000
DH20-P
2500
DH25-P
3200
DH30-P
Type
Rated current [In](A)
[ICT]
[ICT]
[ICT]
[ICT]
X 0.5 X 0.63 X 0.8 X 1.0
100
125
160
200
200
250
320
400
400
500
630
800
630
800
1000 1250
800
1000 1250 1600
1000 1250 1600 2000
100
125
160
200
200
250
320
400
400
500
630
800
630
800
1000 1250
800
1000 1250 1600
1000 1250 1600 2000
1250 1600 2000 2500
1600 2000 2500 3200
DH series
Dimensions
Dimensions, mm
• Fixed types
DH08, DH12, DH16, DH20
DH12-H, DH16-H, DH20-H
■
35
550
15.5
25
250
3-ø11
118
Maintenance space
Vertical terminals
Horizontal terminals
Mounting holes
100
335
149
150.5
25
25
138
165
365
4-ø14
Mounting holes
165(3P)
250(4P)
t2
174
82
82
165
165
Front panel cut
20(max)
With UVT
Controller
180(3P)
265(4P)
240(3P)
325(4P)
30
238
180
15
t1
232
460
490
550 (Arc space)
33
76
329
N
P
C
35
Arc barrier
Lifting
hole
81
240
2-ø11
165
14.5 14.5
194
102
15.5
25
17
Arc barrier
18
P
175 C 175(3P)
260(4P)
Conductor overlap max.
25
52
15
Panel cutout
Main circut terminal size
(t1,t2: thickness p1,p2: interphase pitch)
Horizontal terminals
Vertical terminals
p1
Type
t1
Type
t2 p2
85
DH08
10
DH20
15 85
85
DH12
10
DH12H 15 85
85
DH16
20
DH16H 15 85
DH20H 15 85
• Draw-out types
DH08, DH12, DH16, DH20
DH12-H, DH16-H, DH20-H
81
08
177
177(3P)
262(4P)
204(3P)
289(4P)
240(3P)
325(4P)
draw-out handle
Maintenance
space
9
265
94
141
345
385
120
120(3P)
205(4P)
149
15.5
25
25
150.5
14.514.5
25 25
40
Vertical terminals
P
C
Horizontal terminals
Rear panel cut
400
Main circut terminal size
(t1,t2: thickness p1,p2: interphase pitch)
Horizontal terminals
Vertical terminals
p1
Type
t1
Type
t2 p2
85
DH08
10
DH20
15 85
85
DH12
10
DH12H 15 85
85
DH16
20
DH16H 15 85
DH20H 15 85
Front panel cut
BL
25
141
Mounting holes
4-ø14
Mounting holes
15.5
138
110
94
240
3-ø11
With UVT
Controller
238
204
Maintenance
space
BL
335
42.5
140
Panel cutout
30
For fitted with
breaker fixing
bolts
t2
174
329
460
490
500
9
33
16
232
12
50
R1
t1
N
18
78
25
158.5
52
P
C
CONNECTED position
Control circuit terminal cover (optional)
TEST position
35
2-ø20
Conductor overlap max.
ISOLATED position
Liftin
15
Maintenance
14 21
space
hole
35
194
17
15
ON-OFF
30
button cover
2-ø11
250
164
164(3P)
249(4P)
11
DH series
Dimensions
Dimensions, mm
• Fixed types
DH25, DH30
DH16-P, DH20-P, DH25-P, DH30-P
■
Arc barrier
Conductor overlap max.
12.5
33
76
With UVT
Controller
238
165
217.5
165
365
550
250
4-ø11
20(max)
118
M8 screw
earth terminal
Maintenance space
Vertical terminals
82
233(3P)
353(4P)
82
335
t1
Front panel cut
12.512.5
12.5
25 25 25 25
120 100
550 (Arc space)
232
460
490
N
329
15
Lifting
hole
81
233
293(3P)
413(4P)
293
35
Panel cutout
Main circut terminal size
(t1: thickness p1: interphase pitch)
Vertical terminals
p1
Type
t1
DH25
20 130
DH30
20 130
DH16P 20 130
DH20P 20 130
DH25P 20 130
DH30P 20 130
Mounting holes
4-ø14
Mounting holes
217.5(3P)
337.5(4P)
100
194
102 165
30
17
Arc barrier
228(3P)
348(4P)
25 25
165
P
C
18
228
• Draw-out types
DH25, DH30
DH16-P, DH20-P, DH25-P, DH30-P
N
232
t1
140
With UVT
Controller
draw-out handle
238
Maintenance
space
4-ø14
Mounting holes
172.5
12
172.5(3P)
110
4-ø11
40
P
C
Vertical terminals
Rear panel cut
Main circut terminal size
(t1: thickness p1: interphase pitch)
Vertical terminals
p1
Type
t1
DH25
20 130
DH30
20 130
DH16P 20 130
DH20P 20 130
DH25P 20 130
DH30P 20 130
335
141
Mounting holes
9
265
141
345
385
Front panel cut
BL
Panel cutout
30
293
230(3P)
350(4P)
257(3P)
377(4P)
293(3P)
413(4P)
94
400
230
257
94
Maintenance
space
60
25
For fitted with
breaker fixing
bolts
33
12.5
16
9
490
500
329
460
12
50
R1
18
78
211.5
12.512.5
12.5
25 25 25 25 25 25
100
165
120 100
P
C
Control circuit
CONNECTED position
terminal cover (optional)
TEST position
2-ø20
Conductor overlap max.
ISOLATED position
Liftin
21
Maintenance
14
81 space
hole
35
17
194
15
ON-OFF
30
button cover
250
216
216(3P)
336(4P)
DH series
Dimensions
Dimensions, mm
• Draw-out types
DH40
■
ISOLATED position
21
14
ON-OFF
button cover
42.5
draw-out handle
238
177
204
240
481(3P)
651(4P)
12.512.5
232
12.5
30
BL
4-ø11
With UVT
Controller
9
454(3P)
624(4P)
375
428
295
35
P
C
517(3P)
687(4P)
Rear panel cut
335
141
Mounting holes
400
94
Maintenance
space
140
33
For fitted with
breaker fixing
bolts
17
50
16
18
12
329
460
490
500
R1
40(Conductor overlap max.)
20
78
N
15
50
2-ø20
Liftin
hole
194
15
Maintenance
space
12.5
81
435.5(3P)
605.5(4P)
25 25 25 25 25 25
100
165
120 100
P
C
181
Control circuit terminal cover
CONNECTED position
TEST position
Front panel cut
4-ø14
Mounting holes
120
250
164
25
397(3P)
567(4P)
30
BL
441(3P)
611(4P)
Panel cutout
08
13
DH series
Wiring diagrams (with AGR-11 OCR or without OCR)
■
DH series
Wiring diagrams
Wiring diagrams
4
CT for
neutral line
Main circuit
Control
power
Operation
(+) (+)
Motor charging/
Operation circuit
Continuously-rated
shunt trip
(+)
1
ON switch
(+)
Position switches
Fixed type UVT
Common
Auxiliary switches
PB
3
PB
AUX.
SW
Standard equipment
Optional
4c
01 11
S1
S3
CT1
CT3
05
02
12
03
10
09 08 18 28
24
30
151
141
131
121
111
211
Optional
3c
311
411
511
611
3c
711
811
911
011
UVT control circuit
Over-current release
(type AGR-11 OCR)
Ry
LRC
SHT
2
M
S2
CT2
MHT
UVT
19 29
K
21
k
CT for
neutral line
( )
L
15 25 06 16 26
17 27
X
X
X
X
X
X
22
20
( )
( )
154 152 144 142 134 132 124 122
114 112 214 212 314 312 414 412
514 512 614 612 714 712 814 812 914 912 014 012
X
08
For single-contact indication only 05 and 15
i
Terminal description
Check OCR voltage before connecting
01 21 Control power supply AC200 - 240V,DC200 - 250V,DC48V 01 11 Control power supply AC100 - 120V
11 21 Control power supply DC100 -125V,DC24V
02 22 Control power supply AC10 - 240V,DC100 - 220V,DC24V,DC48V 12 Operation switch,common 03 ON switch
05 Operation indication terminal,common 15 LT trip indication or single-contact indication 25 St/INST trip indication 06 PTA indication
16 GF trip indication 26 System alarm indication 17 trip indication 27 Spring charge indication 10 20 Cotinuously-rated shun trip
19 Separate CT for neutral line (k) 29 Separate CT for neutral line ( ) 08 ,18 , 28 UVT power supply 09 UVT power supply common
UVT power supply
Terminal
100V AC 200V AC
No.
coil
coil
100V
200V
08 - 09
110V
220V
18 - 09
28 - 09
120V
240V
Symbols for accessories
CT1 - CT3 : Power CTs
S1 - S3 : Current sensors
M : Charging motor
LRC : Latch release coil
MHT : Magnetic Hold Trigger
Isolating terminal connector
(for draw-out type)
Manual connector
User wiring
X
Relay or indicator lamp
14
1 : Do
not connected ˝b˝ contact of auxiliary switch to ON switch
in series, otherwise, pumping may occur.
2 : Wiring diagrams changes for capacitor trip.
3 : Use ˝a˝ contact of auxiliary switch of ACB.
4 : For motor split circuit, terminals 02 , 22 and 03 , 04 are used for charging
operation respectively.
400V AC
coil
380V
415V
440V
Position switches
Top
151 141 131 121
Middle 154 144 134 124
Bottom 152 142 132 122
( 4c arrangement)
Top
131 121
Middle 134 124
Bottom 132 122
( 2c arrangement)
Operation/control circuits
01 02 03 04 05 06 07 08 09 10
11 12 13 14 15 16 17 18 19 20
21 22 23 24 25 26 27 28 29 30
Auxiliary switches
111 211 311 411 511 611 711 811 911 011
114 214 314 414 514 614 714 814 914 014
112 212 312 412 512 612 712 812 912 012
(Standard 4c + optional 6c arrangement)
111 211 311 411
114 214 314 414
112 212 312 412
(Standard 4c arrangement)
Designation of terminals for
auxiliary and position switches
1: Common, 2: b-contact, 4: a-contact
1: Auxiliary switch
2: Position switch (for CONNECTED)
3: Position switch (for TEST)
4: Position switch (for ISOLATED)
5: Position switch (for INSERT)
numbers
( 1A,–B,0:C:Switch
Auxiliary switches for microload
CONNECTED position : 121–124 ON
121–122 OFF
TEST position : 131–134 ON
131–132 OFF
ISOLATED position : 141–144 ON
141–142 OFF
INSERT position : 151–154 ON
151–152 OFF
15
■
Accessories
Supplied accessories
Position switch
• Position switch ratings
Auxiliary switch (4c)
ON - OFF operation counter
Indicator cover
Lifting hole (Draw-out type)
Lifting plate (Draw-out type)
Voltage
AC 100-250V
DC 250V
DC 125V
DC 30V
DC 8V
Optional accessories
• Auxiliary switch (Rated)
Category
Voltage
100 to 250VAC
251 to 500VAC
30VDC
125 to 250VDC
For general service
Resistive
Inductive load (A)
load (A)
AC: cos ø ≥ 0.3
DC: L/R ≤ 0.01
5
5
5
5
1
1
1
1
For microload
Resistive
load (A)
0.1
–
0.1
–
Type
Inductive load (A)
AC: cos ø ≥ 0.6
DC: L/R ≤ 0.007
0.1
–
0.1
–
Min. applicable
load
5VDC
1mA
Notes: The chattering of b-contacts due to ON - OFF operation of the ACB lasts for less than 20ms.
Do not supply different voltages to contacts of switch.
• Capacitor trip switch
Item
Type
Rated voltage
Operational voltage
Rated frequency
Rated voltage of shunt trip used
Power consumption
■ Contact ratings for operation indications (for AGR-11, 21)
Voltage
(V)
AC 250
DC 250
125
30
Current (A)
Single contact
Individual contacts
Resistive load Inductive load Resistive load Inductive load
8
3
0.5
0.2
0.3
0.15
0.27
0.04
0.5
0.25
0.5
0.2
5
3
2
0.7
Specifications
AQR-1
100 to 120VAC
Rated voltage X 70 to 110%
50/60Hz
480VDC
100VA
■ Contact ratings of Trip indicator for use with AGR-11or without OCR
Voltage
(V)
AC 250
DC 250
125
30
Switch contact ratings (A)
Inductive load
Resistive load
3
6
0.1
0.1
0.5
0.5
3
3
ALR-0110P
ALR-0101P
ALR-0011P
ALR-0200P
ALR-0020P
ALR-0002P
ALR-1111P
ALR-1210P
ALR-1201P
ALR-0211P
ALR-1120P
ALR-1021P
ALR-0121P
ALR-1102P
ALR-1012P
ALR-0112P
ALR-0220P
ALR-0202P
ALR-0022P
ALR-1030P
ALR-0130P
ALR-0031P
ALR-1003P
ALR-0103P
ALR-0013P
ALR-0040P
ALR-0004P
Resistive
load (A)
11
0.3
0.6
6
10
Inductive load (A)
(cos ø = 0.6, L/R = 0.07)
6
0.3
0.6
5
6
Number of Contact arrangement
contacts INSERT ISOLATED TEST CONN
2c
4c
0
0
0
0
0
0
1
1
1
0
-1
1
0
1
1
0
0
0
0
1
0
0
1
0
0
0
0
1
1
0
2
0
0
1
2
2
2
1
0
1
1
0
1
2
2
0
0
1
0
0
1
0
0
0
1
0
1
0
2
0
1
1
0
1
2
2
2
0
1
1
2
0
2
3
3
3
0
0
1
4
0
0
1
1
0
0
2
1
0
1
1
0
1
1
2
2
2
0
2
2
0
0
1
3
3
3
0
4
Safety Considerations
For safe operation, before using the product read the instruction manual or user manual that comes with the
product carefully or consult the Fuji sales representative from which you purchased the product.
● Products introduced in this catalog have not been designed or manufactured for such applications in a system
or equipment that will affect human bodies or lives.
● Customers, who want to use the products introduced in this catalog for special systems or devices such as for
atomic-energy control, aerospace use, medical use, passenger vehicle, and traffic control, are requested to
consult the Fuji sales division.
● Customers are requested to prepare safety measures when they apply the products introduced in this catalog to
such systems or facilities that will affect human lives or cause severe damage to property if the products
become faulty.
● For safe operation, wiring should be conducted only by qualified engineers who have sufficient technical
knowledge about electrical work or wiring.
●
Gate City Ohsaki, East Tower
11-2, Osaki 1-chome, Shinagawa-ku, Tokyo, 141-0032, Japan
Phone: +81-3-5435-7135~8
Fax:
+81-3-5435-7456~9
URL http://www.fujielectric.co.jp/fcs/eng
Printed on 100% recycled paper using soy-based ink
Information in this catalog is subject to change without notice.
16
Printed in Japan 2004-2 L30 FIS