Download DMC-18x2 COMMAND REFERENCE
Transcript
BB (Binary 9E) FUNCTION: Brushless Phase Begins DESCRIPTION: The BB function describes the position offset between the Hall transition point and θ = 0, for sinusoidally commutated motor. This command must be saved in non-volatile memory to be effective upon reset. ARGUMENTS: BB n,n,n,n or BAX=n where n is a signed integer which represent the phase offset of the selected axes, expressed in multiples of 30°. n = ? returns the hall offset for the specified axis. USAGE: DEFAULTS: While Moving No Default Value 0 In a Program Yes Default Format 0 Command Line Yes EXAMPLES: BB,30,,60 The offsets for the Y and W axes are 30° and 60° respectively OPERAND USAGE: _BBx contains the position offset between the Hall transition and θ = 0 for the specified axis. RELATED COMMANDS: "BA" on page 24 Brushless Axis "BC" on page 26 Brushless Commutation "BD (Binary 9D)" on page 27 Brushless Degrees "BI" on page 29 Brushless Inputs "BM (Binary 9B)" on page 31 Brushless Modulo "BO (Binary 9F)" on page 33 Brushless Offset "BS" on page 35 Brushless Setup "BZ" on page 38 Brushless Zero Note: BB is only effective as part of the BC command or upon reset. DMC-18X2 Command Reference BB (Binary 9E) i 25