Download User Manual
Transcript
E-2005040202-ZL PROFESSIONAL KTV SYSTEMS G SERIES G-60C/G-60E DK-2000 OWNER'S MANUAL ENGLISH Printed in HongKONG ATTENTION TO MAKE SURE FULL AND EFFECTIVE USE OF IT, PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION. AND PLEASE SAVE THIS MANUAL FOR FUTURE REFERENCE. IT'S POSSIBLE THAT THE SHAPE OF THE PLUGS AND JACKS ARE DIFFERENT IN DIFFERENT COUNTRIES, BUT THE CONNECTION WAYS AND OPERATION FOR THIS UNIT ARE THE SAME. 2 CONTENTS Voltage Input 4 Features 5 Signal Cords 5 Front Panel(G-60C) 6 Front Panel(G-60E) 7 Back Panel 8 Before Connection 9 System Connection 10 Remote Control Unit 11 Safety Regulations 12 Specification 13 INTRODUCTION INSTALLATION ADDITIONAL INSTRUCTION 3 VOLTAGE INPUT How to select right voltage input? There's a voltage selector on the back panel of this unit and voltage intensity of this unit has been set between 220V originally. Please check your local voltage intensity comply with this or not before operation. if not, you can select it between 110V by the voltage selector. The power supply cord should be disconnected before adjusting the voltage input. CAUTION 110V 220V 220V THE POWER SUPPLY CORD SHOULD BE DISCONNECTED BEFORE CHANGING THE VOLTAGE SELECTOR ACCESSORIES There is a owner's manual in the package accompany with this unit, please check it when open the package. 4 INTRODUCTOIN Please read this manual carefully before operation. And please save this manual for future reference. FEATURES Inhibiting whistle strongly. Multi-mode singing style. Special design for KTV room, high reliability. Able to connect two group speakers simultaneously. Special drive design of human voice to make voice rich and nature strong cooling fan makes sure long-term working. SIGNAL CONNECTION CORDS red white RCA plugs available Note: RCA plug in red should insert into jack in red. RCA plug in white should insert into jack in white. 5 G-60C FUNCTION INSTRUCTIONS (FRONT PANEL) 2 MICROPHONE OUTPUT LEVEL CONTROL 3 HIDDEN LEVEL CONTROL Adjusting volume of all microphones connected. 1 ECHO CONTROL 4 Controlling echo of microphone input. MIC MASTER VOL ECHO VOL MUSIC VOLUME CONTROL MUSIC VOL STEREO DIGITAL KARAOKE AMPLIFIER G-60C SPECIAL SOUND FEEDBACK HANDLING SPECIAL SOUND EFFECTION DESIGN BIG DYNAMIC CHARACTER.HI-FI HIDDEN ADJUSTING 16 DELAY EFFECT REPEAT BASS TREBLE 1 POWER OFF ON REV EFFECT MUSIC TREBLE CONTROL MIC TONE 2 3 MIC INPUT MIC1 MIC2 MIC3 BALANCE BASS TREBLE 15 MUSIC BASS CONTROL 14 BALANCE CONTROL Balance left and right channel 9 MICROPHONE BASS CONTROL 13 MICROPHONE VOLUME CONTROL 8 MICROPHONE REPEAT FEEDBACK CONTROL 12 EXTERNAL TONE CONTROL JACK 7 MICROPHONE EFFECT FEEDBACK DEGREE CONTROL 11 MICROPHONE INPUT JACKS(1/2/3) 6 MICROPHONE DELAY CONTROL 5 POWER SWITCH 6 10 MICROPHONE TREBLE CONTROL G-60E FUNCTION INSTRUCTIONS (FRONT PANEL) 1 ECHO CONTROL Controlling echo of microphone input. 2 MICROPHONE OUTPUT LEVEL CONTROL Adjusting volume of all microphones connected. 17 AUTO VOCAL FOLLOW 3 HIDDEN LEVEL CONTROL 18 BACKGROUND VOCAL CANCEL 4 MUSIC VOLUME CONTROL 19 PITCH CONTROL SUPER DIGITAL REV/ECHO AMPLIFIER: G-60E KEY MUTI EFF VOL MIC MASTER VOL 16 18 22 26 30 10 8 32 8 34 36 4 38 2 ATSIN REPEAT TIME RATIO BASS ECHO REV 24 28 30 32 34 6 36 4 2 38 16 MAX MUSIC TREBLE CONTROL TREBLE 2 POWER MIN 22 12 10 6 18 26 14 28 12 16 BIT DIGITAL KEY CONTROLLER MUSIC VOL 16 24 14 MIC TONE 3 MIC INPUT MIC1 MIC2 MIC3 BALANCE BASS TREBLE 15 MUSIC BASS CONTROL 14 BALANCE CONTROL Balance left and right channel 9 MICROPHONE BASS CONTROL 13 MICROPHONE VOLUME CONTROL 8 MICROPHONE REPEAT FEEDBACK CONTROL 12 EXTERNAL TONE CONTROL JACK 7 MICROPHONE EFFECT FEEDBACK DEGREE CONTROL 11 MICROPHONE INPUT JACKS(1/2/3) 6 MICROPHONE DELAY CONTROL 5 POWER SWITCH 10 MICROPHONE TREBLE CONTROL 7 BACK PANEL 2 6 5A/220V FUSE HOLD 5 5A/220V AC EARTH CLAMP 1 POWER CORD MICROPHONE BALANCE INPUT/OUTPUT(1/2) 4 REMOTE CONTROL SYSTEM/LINE CONTROL INPUT TERMINAL 3 MIC 1 INPUT MIC 2 COOLING FAN REMOTE CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN GND VISUAL OUT VISUAL INPUT + OUTPUT INPUT LD PRIORITY R - - L CAUTION 110V + A 220V THE POWER SUPPLY CORD SHOULD BE DISCONNECTED BEFORE CHANGING THE VOLTAGE SELECTOR FUSE 10A(110V)/5A(220V) AC OUTLETS L SAME AS LINE VOLTAGE B L R H CAUTION SYSTEM IMPEDANCE LD/CD DVD VCD AUX AUDIO OUT SYSTEM A : SYSTEM B : EFFECTOR MINIMUM 4 MINIMUM 4 UNSWITCHED 300W MAX TOTAL SWITCHED 200W MAX AUDIO INPUT RIGHT CHANNEL SPEAKER OUTPUT 11 LEFT 14 15 16 17 8 VIDEO OUTPUT AUDIO OUTPUT MIXING AUDIO CONNECTION OUTPUT JACK AUDIO INPUT(LD/CD,DVD,VCD AND AUX) LD PRIORITY 7 220V POWER SUPPLY JACK WITH SWITCH CONTROL 13 EFFECTOR L/R INPUT 8 110V/220V VOLTAGE INPUT SELECTOR 12 CHANNEL SPEAKER OUTPUT 9 220V POWER OUTPUT JACK 10 CONNECTIONS BEFORE CONNECTION CONNECTION OF SPEAKER CORDS 1.Press down the button as illustration, insert the cords into the hole. 2.Spring of the button will fix the cords. Please select the suitable speaker cords and connect it through the shortest path. This unit could connect one or two group speakers simultaneously. If only connect one group speakers, you can select connect group A or group B . And please note that phase of the speaker cords are correct or not, if not, the sound will be felt unnatural and absence of low frequency. Attention: ends of the cords should not touch each other. SYSTEM CONNECTION MIC 1 INPUT REMOTE MIC 2 CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN GND VISUAL OUT VISUAL INPUT R - - L + 110V A 220V THE POWER SUPPLY CORD SHOULD BE DISCONNECTED BEFORE CHANGING THE VOLTAGE SELECTOR 10A(110V)/5A(220V) AC OUTLETS L LD PRIORITY L FUSE CAUTION + OUTPUT INPUT SAME AS LINE VOLTAGE R H B CAUTION LD/CD DVD VCD AUX AUDIO OUT AUDIO INPUT LD DVD EFFECTOR SYSTEM IMPEDANCE SYSTEM A : SYSTEM B : UNSWITCHED MINIMUM 4 MINIMUM 4 300W MAX TOTAL SWITCHED 200W MAX VCD AUX EQ 9 CONNECTIONS REMOTE CONTROL UNIT KEY RESET FALLING TONE CONTROL CLAP HISS 4 4 3 CARTOON 3 2 2 1 1 MUSIC VOLUME CONTROL ECHO VOLUME CONTROL EFFECT ECHO MICROPHONE VOLUME CONTROL 10 RISING TONE COMTROL MIC VOLUME MUSIC MUSIC ADDITIONAL INSTRUCTION SAFETY REGULATIONS ABNORMAL PHENOMENA: Please turn off the power and pull out the plug when you find unusual sound or smell when operation. POWER CORDS PROTECTION Don't touch power cords with wet hands to avoid electric shock. Don't put the cords in crowded people. KEEP AWAY FROM WATER AND SUNDRY GOODS DON'T OPEN THE COVER IF NOT GUIDED BY A QUALIFIED ELECTRICIAN PULL OUT THE POWER CORDS TO AVOID FIRE WHEN YOU DON'T USE THIS UNIT. NO! DON'T OVERLOAD IT 11 SPECIFICATIONS Cosmetic changes may be made Power Supply Power Output(RMS) G-60C 125W+125W(8Ohm) G-60E 125W+125W(8Ohm) Standard Power Supply AC 110V-220V/50Hz AC 220V/50Hz THD 0.3% 20Hz-20KHz Frequency Response 20Hz-20KHz 2dB Input Sensitivity/Impedance Microphone Power Consumption G-60C 380W G-60E 380W 0.5mv-100mv/2KOhm Line Video 0.707v/51KOhm AC Power Outlets 1Vp-p/75Ohm Pitch Control Switched 200W Unswitched 300W Music Bass(Gain/Attenuation) 12dB Treble(Gain/Attenuation) 12dB Microphone Bass(Gain/Attenuation) Treble(Gain/Attenuation) Static Power Consumption G-60C 20W G-60E 20W 12dB 6dB Output Sensitivity/Impedance Audio 0.707V/1KOhm Vedio 1Vp-p/75Ohm Net Weight G-60C 10.5KG Gross Weight 12 KG G-60E 12 KG Gross Weight 13.5KG Short Circuit Protection Output Impedance Recommendatory Impedance 12 2-16Ohm 8Ohm Dimensions 495x426x190(MM) E-2005040202-ZL