Download FC3000S Microprocessor Control System for Elevator User Manual

Transcript
FC3000S Microprocessor Control System for Elevator
same time, the buzzer for overload will keep buzzing.
15.Door open or close only when the button is pressed
In inspection mode, door open or close only when the button is pressed. When the door opening or closing
button is pressed, the door will open or close; the action will stop as soon as the button is released.
16.Attendant change the running direction
In attendant mode, when the elevator has not started running yet, the attendant can press UP or DOWN
button to change the elevator running direction.
17.External call of this floor can decide the direction of the elevator when it has no direction
When the elevator stops at a certain floor without direction, External call of this floor can decide
the direction of the elevator.
18. Farthest call decide the direction of the elevator
The elevator answers the farthest external call, slows down and stops, Then the running direction of the
elevator is consistent with the direction of external call until the door close, even there is no other instructions.
Before the door closes, the direction of elevator is determined by the farthest external call.
The time from the elevator stopping to the door is closed is called pre-direction time.
19.Cancel wrong call signal in the car
In attendant 、fire or special mode, if passenger presses some button to register and then find that it is not the
target floor he wants to go, he can press the same button again and the selection will be canceled.
Attention: If “internal call signals elimination” in the control parameter is selected as “YES”, this function
will be also activated in the automatic run mode.
20.Automatically cancel signals in the car when changing running direction
When the elevator is changing direction at the terminal floors, it will cancel all call instructions in the car.
21.Direct running for full loading
In automation mode, when overload the elevator will answer internal calls only, ignoring external calls.
22.Attendant button for direct running without answering hall call
In attendant mode, before the elevator slows down, if direct run button has been pressed, then during this
trip, it will answer internal calls only, ignoring external calls.
23.Bell chime
During the slowdown and leveling process, the bell chime on the top or bottom of the car will ring to
remind the passengers inside or those waiting outside that the elevator is leveling.
24.Automatically switch off illumination and fans during waiting
If there is no instructions in a certain period of time set by menu, illumination and fans will be switched off.
As soon as the elevator receives instruction, they will be switched on and put to use,(need to add relay).
Attention: time can be set through the 13th option “illumination off delay in the car” in time parameter
menu.
5-3
Zhuhai Alpha E&M
Co., Ltd.