6.1.2.12
Floor memory learning
Floor memory learning
Start floor memory learning?
Start
Back
At this interface, Press ENTER (Start), the elevator begins floor memory learning automatically. The
interface changes to as follows:
6-8
Floor memory learning
Floor2
Learning
Pulse=00037252
End
While floor memory learning, the elevator will be sent back to the lowest floor first. Then it will run to
the top floor. The learning process will end automatically. The elevator runs at inspection speed during the
learning process.
If failure occurs during the learning, press ENTER to end the process.
There will be corresponding tips if the learning succeeds or fails. Pulse is the data got from the lowest floor.
After the learning ends, the data is all the pulse data got from bottom floor to the top floor.
6.1.2.13 Language
There are Chinese and English menu. Use this option to select the language, Chinese or English.
6.1.2.14 About the system
6.1.2.15 System time
Through this setting the system time can be adjusted. System time will be utilized while recording failures.
When the system is powered off, the system clock is maintained by batteries. If the batteries voltage is low, the
time will be incorrect. So please change the batteries in time. The standard life span of battery is two years. The
battery has certain shelf life. Our warranty of battery is: one year after leaving the factory.