Download DIN-20-BAS
Transcript
Industrial Control & Instrumentation Din rail isolator & transmitter din20 l l l din20-bas: Thermocouples, Pt100, 4..20ma, 0..10V process inputs. din20-vac: True RMS AC/DC Volt, Amper input. din20-tac: Tachometer 0.01 Hz.. 50KHz pulse input. l 4 alarms associated to 2 output solid state relays. l l Isolated 4/20ma and 0/10V outputs. RS485 modbus RTU serial communications. General description The din20 din rail isolators are based on Arian id20 digital panel indicators, having the same funtionalities except for not having a display and enhaced isolation characteristics. Composed by 3 sub-models (din20-bas, din20-vac, din20-tac) they cover a broad range of input types. Isolation Complete galvanical isolation between: power supply, input, analog output, solid state relays and RS485 communications. Inputs The din20-bas includes thermocouples, Pt100, 4...20mA, 0...10V and 0...50mV process inputs. The din20-vac is a AC true RMS volt and amper input instrument, (also bipolar DC) with several scales. May be used with shunts, current transformers or direct measurement of AC/DC voltages up to 600V. The din20-tac is a tachometer or rate meter, only accepts pulse inputs e.g.. NPN, PNP and Mechanical Switch. Frecuency measurement is done counting the input pulses and simultaneously measuring the time among them. This method allows precise and quick readings especially at low frequencies where the measurement is obtained mainly from the period (time) among pulses. Simplifies input programming not having to define "time windows" on which the count is carried out. Alarms Possess two output solid state relays, each one corresponds to 2 programmable alarms (high and low). Alarms can be absolute or relative to a general set point. Analog output Isolated analog outputs 0/10Volt, 4/20mA active or loop powered. Programming Set up and configuration is done by the Arian RPS software running on a PC. Computer connection is made to the RS485 port (using the ISO485 interface) or to the internal connector with the RPS interface. Since funtionalities are exactly equivalent with the id20 panel meters, detailed configuration is found on the id20 user manual. BRO-DIN20-E-03-2009, http://www.arian.cl 1 TECHNICAL SPECIFICATIONS INPUTS din20-bas Resolution 16 bit a/d, CMRR 100 dB min., 400 VAC. Min. Input break protection TC with preset action. Thermocouples (100 ohm max.): Centigrade Degrees or Fahrenheit J (-60, 760) °C k (-100, 1372) °C. T (-86, 400) °C. R -1 mV, 1767 °C. S -1 mV, 1764 °C. B -1 mV, 1815 °C. N (-139, 1298) °C. E (-176, 750) °C. Platinel (0, 1394) °C. C (0, 2314) °C. D (0, 2314) °C. G (0, 2313) °C. PT100 ( -136, 450 ) °C DIN43760, alpha=0.0385 4...20 mA, 0...20 mA, 0...5 V, 1..5 V, 0..10 V, 0..50 mV, scalable for engineering units. din20-vac: Resolution: Dc: Ac: Scales: din20-tac: Pulse inputs: NPN, PNP, Mechanical switch, TTL, High voltage (500 V). Provides feeding for input sensor, +5, -7.5 Vdc, 30mA max. Frequency range 0.01Hz ... 50KHz ALARM RELAYS Two solid state bipolar ( for DC or AC use ) relays outputs for alarms 400 VDC max and 200mA max. This must be used with external larger power relays unless are conected to low power loads such as PLC or DCS inputs. Normally open or normally close software configured. Independent alarm outputs, each one with high and/or low alarm, with absolute or relative set point. RS485 Modbus RTU protocol serial communications, half duplex (RS485 not RS422) Opto isolated up to 5kV 18 bit a/d, CMRR 100 dB min., 400 VAC. Min. Bipolar simetrical input (positive/negative voltages/ currents) True RMS. 5 Ampers, 60mV, 2V, 6V, 20V, 60V, 200V, 600V ANALOG OUT Loop powered: 4... 20 mA, loop powered, Voltage drop 4.5V max., Operating voltage 30V max. Opto isolated (5kV). Active loop: 0-10V and 4..20mA Active loop, driving up to 14 volts onto loads (700 ohms max. load) Opto isolated (5kV). POWER SUPPLY: Low noise switching power supply. 5kV min. isolation from analog input. 20Vdc... 28Vdc, 3 W max. CONSTRUCTION: Reinforced polyester Total Dimension: Weight: Operation temperature: BRO-DIN20-E-03-2009, http://www.arian.cl 121 x 98 x 23 mm. 200 grams. 0 ... 50 °C. 2 PROGRAMMING Set up configuration is done with the RPS (remote programming ) software provided on http://www.arian.cl/downloads/arianrps.zip and running on windows PC. Connection can be done from the RS485 lines using the ISO485 interface to the PC RS232 comm port . Also may be done using the RPS interface cable plugged to the internal connector, taking care of the “UP” direction for the connector, as seen on the figure. Remove the four top cover screws for accessing the RPS connector and other internal jumpers needed for setting the input and output type. UP RPS Connector The RPS software will recognize the device and load the proper driver for reading and writing configuration parameters. Since the din20 is functionally equivalent to the ind20 panel meters, you may refer to the id20 user manual for further references. BRO-DIN20-E-03-2009, http://www.arian.cl 3 Analog output and solid state relay outputs Power Supply +20... +28 Vdc, 100mA max +V/I -V/I Analog Out +0/10Vdc A RS485 17 Gnd 16 -420A option 0/10V and 4/20mA active outputs. 24V Gnd 18 -420L option 4/20mA loop powered pasive output. 15 14 + Gnd -4/20mA 13 R load 700 ohms max +4/20mA 12 4.5V min., 30V max Modbus RTU B 11 10 8 7 200mA max SSR Rele Outputs O2 O1 Com 9 200mA max Out 2 0.2A / 250Vac max Out 1 0.2A / 250Vac max Common 6 4 400Vdc max, 250Vac max _ BEU / AZUL + INPUT Gnd V+ 5 V GRN / VERDE Gnd -4/20mA Gnd TC 0/10V 0/60mV +4/20mA PT 100 3 BRN / CAFE 2 1 fig-din20-1 Input connections CAUTION: Set internal jumpers 4 -7.5V INPUT 3 2 1 +5 V S1 HV _ Mechanical switch BEU / AZUL V LV 3 V + BLK / NEGRO Low voltage input pulse Inductive proximity switch NPN, PNP High voltage input pulse _ _ V + 60mV, 2V V + 5 Amp + Caution: Set internal jumper 2 6V, 20V, 60V, 200V, 600V HV 1 INPUT 4 Gnd V+ 5 din20 -BAS _ + BRN / CAFE _ INPUT 4 Gnd 5A 5 din20 -VAC Gnd -7.5V +5V S1 HV 5 din20 -TAC Gnd GRN / VERDE _ BEU / AZUL + Gnd Gnd -4/20mA TC 0/10V 0/60mV +4/20mA PT 100 3 BRN / CAFE 2 1 fig-din20-2 BRO-DIN20-E-03-2009, http://www.arian.cl 4 Input configuration jumpers din20-BAS Thermocouples, Pt-100, 0-50mV 4-20mA, 0-20mA 0-10V, 0-5V, 1-5V din20-TAC TTL Low Voltage PNP NPN Mechanical Switch din20-VAC 5 Amp. 60mV 2V 6V 20V 60V 200V 600V din20_03 BRO-DIN20-E-03-2009, http://www.arian.cl 5 4/20mA and 0/10V active output configuration jumper 4 / 20mA 0 / 10V din20_04 PART CODES: din20-BAS : thermocouples, pt100, 0-10V, 4-20ma, ... -TAC :rate meter -VAC :amperimeter, voltimeter DC and AC true RMS. Optional -420L -420A -RS485 4..20mA pasive loop analog output. 4..20mA active, includes 0..10Vdc analog output. modbus RTU serial communications Example: din20-BAS-420A-RS485 MORE INFORMATION: ARIAN S. A. El Comendador 2340, Providencia Santiago, Chile Fono/Fax 56-2-4218333 [email protected] www.arian.cl C Copyright ARIAN S.A. 2009. BRO-DIN20-E-03-2009, http://www.arian.cl 6