Use the following procedure to perform a sequential firmware upgrade in a dualredundant configuration (the two controllers are arbitrarily designated Controller
A and Controller B.):
1. Enter the SHUTDOWN THIS_CONTROLLER command at the HSJ> prompt
for Controller A. This causes (live) Controller B to assume control of the
shutdown Controller A’s drives.
2. Remove the EMI shield (if attached) from the shutdown Controller A.
3. Press shutdown Controller A’s eject button, and remove its program card.
4. Press and hold Controller A’s OCP reset (//) button while pushing in the new
program card. Be sure the eject button extends outward almost even with the
card.
5. Release Controller A’s reset (//) button.
6. Enter the RESTART OTHER_CONTROLLER command at Controller B’s
HSJ> prompt.
7. Press the OCP reset (//) button on shutdown Controller A. Controller A now
re-initializes and reestablishes communication with Controller B and the host.
8. Repeat the procedure, interchanging Controller A and Controller B. This time
Controller A, upgraded to HSOF V1.2 first, will serve all devices to the host.
After you complete the upgrade, use the OpenVMS operating system Preferred
Path utility as required to restore the desired controller-to-drive assignments.