Download External Memory PHY Interface (ALTMEMPHY) (nonAFI
Transcript
Chapter 3: Functional Description—ALTMEMPHY (nonAFI) Functional Simulation—the ModelSim Wave and Transcript Window 3–35 This process continues until all 360° (full rate) or 720° (half rate) worth of phases are sampled and the available data window is measured. The length of time between each read is determined by the PLL reconfiguration requirements and the compare and store operation of the sequencer, which is device and configuration dependant. The gap observed between the first and subsequent reads is greater as the sequencer must set the PLL into phase stepping mode. Once a successful range of phases has been sampled, the sequencer center aligns the PLL phase within this calibrated window. This can be observed on the PLL reconfiguration bus as a burst of phase changes without any read accesses. In the example, this calibration is setting on the capture clock phase, so you would (in a functional simulation) expect a phase of around –90° to be selected. 48 phase steps were reported during the generation, and a burst of 10 PLL reconfigurations can be observed (360/48 * 10 = –75°). Refer to Figure 3–10 on page 3–36. 1 © January 2010 In Arria GX, Stratix II, and Stratix III devices, calibration is performed on the resynchronization clock. Altera Corporation External Memory PHY Interface (ALTMEMPHY) (nonAFI) Megafunction User Guide