Download Atwood Hydroflame Furnace Electrode Gasket 32172 - Atwood hydro flame 8500
Transcript
/iltAtwood' Atwood Mobile Products LLc 1120 North Main Street . Elkhart, lN 46514 USA : 800-546-8759 Canada & USA : 800-825-4328 lnternet: http://www.atwoodmobile.com /A\ (w) \ \.-- Failure to install furnace according to this installation instruction nullifies the furnace warranty. Models 8516, 8520, 8525, 8531, 8535 8516-LD, 8520-LD, 9525-LD, 9531-LD, 8535-LD 1 522, 2334, 1 522-LD, 2334-LD Technical lnstallation Manual Effective 10/10 A technician to install an Atwood - hydro flamerM furnace. Should you require further information, contact your dealer or nearest Atwood Mobile Products Service Center. This furnace design has been certified for installation in recreation vehicles as a MSP Category lll furnace. Follow this installation instruction to insure safe operation of the furnace. // TM --z< \qSTEyy/ English, Frangais (et Canada) This instruction manual is for use by an authorized service Literature number 30090 hydro flamerM 8500-lV Series Furnaces wlnu*c Avoid possible injury or death lmproper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or loss of life. Refer to the installation instructions and/or owners manual provided with this appliance. lnstallation and service must be performed by a qualified installer, service agency or the gas supplier. TO THE INSTALLEH: .TO THE CONSUMER: LEAVE THIS MANUAL WITH THE APPLIANCE. RETAIN THIS MANUAL FOR FUTURE REFERENCE. SAFETY ALERT SYMBOLS Safety Symbols alerting you to potential personal safety hazards obey all safety messages following these symbols A wanuxc Avoid possible injury or death A caunoru Avoid possible injury and/or propertv damaoe A wanumc FIRE OR EXPLOSION lf the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS: . r . . . o . Extinguish any open flame. Evacuate all persons from the vehicle. Shut off the gas supply at the gas container or source. Do not touch any electrical switch, or use any phone or radio in the vehicle. Do not start the vehicle's engine or electric generator. Contact the nearest gas supplier or qualified service technician for repairs. lf you cannot reach a gas supplier or qualified service technician, contact the nearest fire department. Do not turn on the gas supply until the gas leak(s) has been repaired. lnstallation and service must be performed by a qualified Service Technician, Service Center or gas supplier. . INDEX SPECIF|CAT|ONS. MODELS ...........2 ..,.,,.,,.2 OIMENSIONS WEIGHT ,,,,.2 ,,,,,,.,,2 MINIMUMCLEARANCETOCOMBUSTIBLES: ... .....2 INSTALLATIONANDSAFETYCODES ,,....,2 GENERAL FURNACE LOCATION .,.,.,..,.,2 DOORSIDEWALLCUTOUT .........3 DOORINSTALLATION. .....3 LD VENT SIDE WALL CUTOUT LD VENT INSTALLATION VERTICAL INSTALLATION CAULKING DUCTING OPTIONS 4 4 AREAS ...,.4 ...,.,,.,4 REQUIREDMINIMUMDISCHARGE,....,...,,4 ......5 ... ... ...5 HORIZONTALORVERTICALDISCHARGE ...........5 EXTENSTONBOXDISCHARGE... ..........5 FLEXADAPTER PLATE .....5 PROPANE GAS CONNECTION .... ..6 ELECTRICALCONNECT|ONS... ...........6 CONDUCTORSIZINGTABLE ..,....,6 POWERSUPPLY .....6 THERMOSTATINSTALLATION..... .........6 OPERATING INSTRUCTIONS .., .,, ,,7 To Shut Down . ..... ..7 SYSTEM CHECKS ......,.,..7 PROPANEGASPRESSURETEST ...,.,,.,,,7 STATIC PBESSURETEST.. .. , ,.,...7 IGNITIONCONTROLDIAGNOSTICCODES ......,.,.7 STANDARD3TRIES FOR IGNITION CONTROLS , ,,, ,,7 2-STAGE 3TRIES FOR IGNITION CONTROLS , , . . . . . .7 WIRING DIAGRAMS .. .......9 Bs-IVWIRING& LADDER DIAGRAM .........9 85-IV-LDWIRING&LADDER DIAGRAM ......9 1522,2334LDWIRING&LADDERDIAGRAM .. .,..10 1522,2334 WIRING & LADDER DIAGRAM ...... ....10 Parts Drawing .... ..........11 FLEXIBLE DUCTING SYSTEMS HARD DUCTING FLOOR SYSTEMS Parts List minimum return air. Failure to meet minimum return alr requirements nullif ies f urnace warranty. When frrnuces are installed to minimum clearances, an additional furnace' or a t 6 in' of return air must be provided to blower side of 2i ciearance the full length and height on blower slide must be SPECIFICATIONS MODELS 8520-lv 8516-lv Models 8525-lv 8531-lV 8s35-lV 8535LD 34,000 8516-LD 8520LD 8s25LD 8531LD BTU lnout 16,000 20.000 25,000 30,000 Duct Static Pressure 20'wc .10" WC .10" .10" .10" WC WC WC Amperage (AMPS) 4.6 4.6 7.6 7.6 9.8 Watts 55 55 91 91 118 Power Supply 12 12 12 12 12 (Volt DC) 80 in2 80 in2 80 in2 80 in2 80 in2 Minimum Return Air 65 in2 65 in2 65 in2 65 in2 65 in2 BTU lnput Duct Static Pressure Amperage (AMPS) Watts Power Supply .10'w.c Recommended Return Air Minimum Return Air (wc Furnace must 22,000 .10" w.c. .10'w.c. 6.5 13.2 58 122 ao 158 12 12 12 12 A a a in2 80 in2 80 in2 B0 in2 65 in2 65 in2 65 in2 65 a in2 a UMN) DIMENSIONS All Models /lac Door widrh Height 16-112" 19-114" 7-318" 9-114 5-3/8" Vent LD Depth '18', 114" WEIGHT Furnace Boxed Standard 30 lbs 32 lbs to these venting of other aPPliances. a 80 installed and vented lmproper installation location may cause furnace to produce negative pressure, affecting combustion air or w.c. .10" be lmproper installation, adjustment, alteration, service or maintenance can cause injury or property damage' Hiqh 34,000 10.2 4.8 (Volt DC) Low 23,000 Hiql' wannrnc lnstructions. 2334 't522 Low 15 000 A CARBON MONOXIDE POISONING . . . Recommended Return Air Models # maintained. 2-Staqe 31 lbs 33 lbs a a *ARN'NGS "*,r,"oL 'NSTALLATI.N DO NOT install furnace on material that restricts return air, like carpet or any soft material such as vinyl' DO NOT install furnace where clearance to combustibles cannot be maintained. DO NOT modifY furnace in anY waY' DO NOT alter furnace for a positive grounding system' DO NOT hi pot furnace unless electronic ignition system (circuit board) has been disconnected' bO ruOr use battery charger to supply power to DC model furnace even when testing. DO NOT use 12O-volt AC current with DC models' DO NOT use furnace cabinet area as a storage compartment DO NOT vent furnace with venting system servlng another appliance. DO NOT vent furnace to an outside enclosed porch area. DO NOT use for temporary heating of buildings or structures under construction. gas Protect building materials from degrading from flue exhaust. Protect furnace electrical components from water' Compartments must be closed when operating unit' MINIMUM CLEARANCE TO COMBUSTIBLES: combustible buildino materials must be of unit' width and prwiOeO tne full length ii;o;b;;rds. walls & similar Horizontal ToP and Sides 1/2" Vertical Top and Sides 1/2" Rear Rear 1 1 INSTALLATION AND SAFETY CODES Bottom 3/16" Bottom 0" (slide plate end) . . provided . Soacinq of 1/4" to ducting within 3 ieet of furnace must be LL ri.t.d wire boLind vinyl ducts are used All ducting material O" rated ior continuous use at minimum of 200"F' J[[.i ,..Jt . Clearances are specilically for plywood or similar building materials sriiornOing the furnace (i.e. Furnace should not be located under could furniture oiin a closet space where clothing or other material . . in the USA and Canada - follow all applicable state and local codes o1: standards current to refer reguiations, or absence of local codes Recreation Vehicles ANSI A1 19.2/NFPA 501C B149 National Fuel Gas Code ANSI 2223'1 andlor CAN/CGA lnstallation Codes fille 24 Federal Mobile Home Construction & Safety Standard' the not applicable' is Standard this when or patt 3280, CFn, Home Siunblio ror. Manufactured Home lnstallations (Manufactured SiG., C".rr.ities and Set-ups), ANSI A255'1 and/or CAN/CSAZ24O MH Series, Mobile Homes. CSA Ground National Electrical Code ANSI/NFPA No' 70 and/or be located). rating is a thermal rating determined under Furnace installation. "ifi.i.n.y continuous operaiing co-nditions, independent of any Etti.i.n.v rate ls giv-en at 77% minimum; actual elficiency rating may be higher. All return Reiurn airls supplied through openings in furnace casing. p".*g". ,Lit o" kept cleai for furnace to function properly' "ii clearance to floorboards, walls & similar n"t", to material' The total unobstructed return air building combustible opening size(s) muit not be less than specified in specification frini.r, - c22.1 Park Trailers ANSI 119.5 GENERAL FURNACE LOCATION a a lnstall furnace through an exterior wall' doors or DO NOT install furnace near iilt-out rooms, slide-outs' other projection that could obstruct furnace exhaust' Locate furnace near midpoint of coach for single furnace applications. lnstallation must provide accessibility if any repairs are necessary to the furnace. Failure to meet this requirement will create additional labor costs that will be the responsibility of the installer. DO NOT install vent in areas where projection or door openings come within 6" of vent tube opening. DO NOT install furnace in an area where wires, pipes or other ob.jects will interfere with installation or operation of furnace. DO NOT install furnace on material that restricts return air, such as directly on carpet, or soft material (like vinyl). lf you must install furnace on carpet or soft material, install furnace on cleats, or on a wood or metal panel extending the full width and depth of furnace plus minimum clearance to combustibles. DO NOT use peiroleum or cilrus type cleaner on plastic parts, as damage may occur. Properly adjust draft cap DO NOT allow furnace tabs to protrude through sidewall cutout opening during installation process until door is installed and tabs are bent over. Take care when handling or brushing against all sheet metal edges to avoid personal !njury. to prevent carbon monoxide from entering coach. DOOR INSTALLATION . . . . o CAUTION Personal lnjury A A wlnu*c CARBON MONOXIDE POSIONING . . Standard Door or Deluxe Door may be used alone or with optional Recessed Bezel. See instructions supplied with bezel for cutout hole and mounting instructions. The furnace must always be installed level (front to back, side to side) to prevent water intrusion lnto the interlor. To prevent moisture f rom entering inside of coach, apply RTV type sealant. The door bezel must fit tightly, to prevent water leakage. Doors are designed to allow water drainage in either horizontal or vertical installations. Proper location of Vent Assembly is important for proper exhausting of fumes and proper function of furnace. With wing nut (C) loosen on draft cap assembly, close door (A) and pull draft cap assembly (D) fonntard until it pushes against the screen (B). Open door and tighten wing nut. Close door and check to insure draft cap is against door screen. *o*wrttc CARBON MONOXIDE POISONING Properly seal door/vent assembly to prevent carbon monoxide from entering coach. o DO NOT draw combustion air from living area. . DO NOT vent exhaust air into the living area or an enclosed porch. DOOR SIDEWALL CUTOUT * Recommended exterior wall thickness 0" 1o 1-112" ABC - SIDE RIGHT SIDE 2-112'maximum. Figure 2 Pull furnace forward until mounting tabs protrude through exterior wall. The edge of control box must be flush with coach's outer skin 2. (VERTICAL installation -gas connection must be on bottom). Apply RTV type sealant to entire back flange of bezel creating a watertight seal. 4. Secure by inserting door bezel onto furnace tabs through notches on door bezel. The gas inlet plug and slide plate must be installed in the closed 5. position and door bezel flange inside of slide plate. lnsert six mounting tabs lhrough slots provided in door bezel. Bezel must be tight against casing and cuiting into RTV sealant. b. Bend tabs flush with door bezel, aligning holes in tabs with slots in door bezel. lnstall 12 mounting screws. DO NOT deform bezel. 7. 8. The door bezel must fit tightly against sidewall to prevent water leakage. o Fill tab slots with caulking after securing wlth screws. 10. Remove excess sealant from around door bezel and visually inspect door bezel to make sure it is completely sealed. 11. Secure mounting legs to floor for horizontal installation. For vertical units use vertical mounting bracket and self{apping screws to hold furnace to floor (tabs on control box can be used to secure furnace). For Vertical Kit Part No. see parts list. 12. Fasten door with fasteners provided. t. Figure DO NOT oversize hole - 1 over sizing can result in water leakage. A *o*,u'rc CARBON MONOXIDE POSISONING Properly seal door coach. to prevent carbon LEFT SIDE monoxide from entering VERTICAL INSTALLATION CAULKING AREAS LD VENT SIDE WALL CUTOUT I ,/ D A Figure 4 B You Must Caulk- all areas shown' t- . . L c_r a Around entire red gas inlet plug "C"' with sheet metal Around entire black stiJe plateldges were it mates "8". plug "D" Alound entire gas line where it enters gas inlet of sheet metal casing corners "A' bottom two of ni..g *"fJ.O ioints and irere door tlange covers slide plate' DUCTING OPTIONS REQUIRED MINIMUM DISCHARGE Models Required Discharge Area 24 in' 36 in2 48 inz 36 in2 48 in2 48 in2 8516,8520 8s25, 8s31 otretr 1522 2334 All Models using toP or C --a-- bottom discharge oPtions All vertical installations i A B- 48 in2 a': Figure 3 Side Wall Cutout A B 2-3t8" 1-1 12" J- llz Diameter hole * Recommended wall thickness 0" 1o 2-112" OOfrf Ot oversize hole - over sizing can result in water leakage' LD VENT INSTALLATION 1. 2. J. 4. tr 6. Locate vent hole cutout as called out oiirii-rlz" dlameter hole through sidewall of coach' Remove vent and vent ring from furnace' hole backsi-de of wall, lining up hole in wall with l;;;;iir;;;.lrom for vent in furnace. ippty seatant to back of vent ring and vent cap base' installations and inllu'ir u"nt assembly with HOT it top on horizontal for vertical installations Vent ring must slip iloT ."rinrittn air intake tube' Secure to wall with four (4) i.Jil"".ligr,t;ide screws not Provided. ili,.i*."rrlUfy must maintain minimum overlap ot 1'114" on exhaust NOT exceed trne unO 1/2" minimum on combustion air tube' DO maximum wall thickness. ol to floor with two (2) screws' through legs on back vertical units use veriical mounting bracket and selfJ"ri.g. be i*oin"o screws to hold furnace to floor (tabs on control box can parts list' see No Pan Kit Vertical For irtnu."). ;t:Ji i; $;;;;i;;;" f;t t..r," Figure 5 When Prooer duct installation is critical to operation of furnace at 200'F' use for continuous rated muter,iars i;r,!ili.; ,il.i;,'u*se similar combustible See minimum clearance to floorboards' walls & materials. building Provide Fach 4-inch duct openinq provides 12 in2 of discharge area' i.'"oi n[n-.rot'""ole duct discharge area ior each I" "-tir'izregister used closeable minimum Use ol 2" ducting does not count toward achleving no return ;.;;;g.lA;ir"ements. Ducting into dead air spacewithachievins tank areas,"do"s not count toward ;i;, ;;.i;h;lding minimum discharge requirements' nJir.iJr.tlng insltallation to obtain air rise of 100'F-130"F' . Horizontally installed furnaces - using side duct options - must have a minimum of one duct from both lelt and right side of casing EXTENSION BOX DISCHARGE Floor cutout dimensions FLEXIBLE DUCTING SYSTEMS 18" When designing flexible duct systems: Avoid sharp bends or crushed ducts. Stretch all ducts and run them directly to outlets, keeping quantity and angles of bends to a minimum. . . 1. Remove knockout plates from desired outlets. 2. Attach a duct adapter to each opening by inserting flange over casing, locking the tab into casing slot and turning adapter 90" Attach and secure lour-inch flexible ducts to adapters. Run ducts to desired location within RV, secure to registers. Additional ducting may be needed to maintain correct static a 4. E B 1t2" c D E 5" to 114" INSIDE WALL pressure. HARD DUCTING FLOOR SYSTEMS When designing hard ducting systems: Undersized ducting will cause high temperature limiting. Oversized ducting will cause inadequate air flow from registers. When hard ducting is 1-112" in depth, an additional flex duct may be needed to maintain installation duct static requirements. DO NOT install floor registers within 2 feet of return air openings. See ducting option from casing top and bottom areas. These options can be with flex ducting or by hard ducting installations. Hard ducting can be sealed using an optional gasket and plenum plate kits. See parts list. 1. HORIZONTAL OR VERTICAL DISCHARGE 2. o . . . Figure 7 A plenum plate may be used for top or bottom discharge installation. A casing extension box adds 6" of depth to furnace casing. To order see parts list. - Floor cutout dimensions A 8-1t2 B c D s-'t/2" 6-1t4" 1t4" 3. 4. 5. 6. 7. Remove three knockouts from rear of furnace. Place extension box with foam gasket against furnace, making sure the three openings are enclosed within extension box. With extension box held in place, secure with lwo 112" sheet metal screws not provided. Fasten plenum plate over cutout. Position gasket on plenum plate. Set furnace on gasket; make sure gasket remains in position. Fasten extension box to floor with 1i4" sheet metal screws or staples. Additional ducting can be used to maintain correct static pressure or as desired. FLEX ADAPTER PLATE Figure 6 Units can be installed as bottom/top or vertical bottom discharge systems. 1. J. 4. 5. 6. 7. Remove bottom / top discharge or side cover plate, these ducting options must be connected to a ducting system. lnsure sealing of all joints when use of a gasket and plenum plate for hard ducting configurations. Other methods of sealing furnace to the floor are acceptable as long as clearances and seals meet requirements of clearances and temperature. Fasten plenum plate over floor cutout. lf a gasket and plenum plate is not used seal furnace to hard duct system making sure seal is airtight. Position gasket on plenum over hole opening. Set furnace on gasket; make sure gasket remains in position. Additional ducting can be used to maintain correct static pressure or as desired. Figure 8 A flex adapter may be used to provide more flexibility for alignment of discharge opening on hard duct systems. This system can be used on all models installed horizontally or vertically providing ducting from rear of furnace without using side ducts. Use of a flexible mounting plate kit is available. See parts list. Remove three knockouts from rear of furnace. lnstall duct adapters in each opening. Place flex adapter plate with foam tape against hard ducting making sure openings line up. With plate held in place, fasten plate to ducting using screws or staples as need to keeP it flat. 4. ( A lnstall three duct adapters into flex adapter plate. Attach flexible ducting from furnace to ilex adapter plate and secure ducting in place on both ends. Additional ducting can be used to maintain correct static pressure or as desired. 6. 7. PROPANE GAS CONNECTION 1. 2. Connect gas line to brass fitting located on right side of Jurnace. Some models will have fittings at the rear or right side outside of the casing. Be suie all male pipe threads, other than llare fittings, are treated with a sealing compound resistant to the action of propane (LP) gas. DO NOT put sealing compound on flare fittings. Use two wrenches to hold brass fitting and flare nut when tightening gas line to brass fitting. DO NOT iwist valve assembly. 3. 4. This connection is for low-voltage battery or direct current only. Do not connect to 120 or 240 volts AC. . . . . . . 1. 2. 3. 4. 5. Figure 9 . A 1/B" N.P.T. plug is accessible for test gauge connection on gas valve assembly for pressure testing. A 3/8" flared fitting connection is provided at gas control valve inlet for gas supply connection to furnace. The gas supply line of the furnace must be of adequate size to provide 1 1" W.C. gas pressure. This pressure must be mainiained under maximum llow conditions r with all gas appliances in operation. Remove slide plate and gas inlet plug from furnace. lnsert gas line ihrough gas inlet plug (DO NOT CUT). Connect gas line through gas inlet plug inside furnace casing immediately ahead of gas control valve. . . o . wanNrNrc . . Label all wires before disconnecting for servicing. Wiring errors operation after servicing. Disconnect electrical power before servicing. CONDUCTOR SIZING TABLE Maximum 10% Voltage Drop - (12VDC) Current draw (AMPS 10 8 9 7 b 4 5 Amps Max. Lenqth of SAE conductor (ln feet) from source Gaqe F,7 17 21 19 25 29 43 34 18 ca /a 29 26 az 65 87 16 Atwood Mobile Products highly recommends the use of an electronic (solid state) converter with clean power output. This will assure the li{e of ihe electronic controls and motor life could be extended beyond typical linear converter applications. o can cause improper and dangerous operation. Verify proper . Route wiring to left side of lurnace. Connect red wire to positive side of power supply. Connect black wire to grounded side of power supply. Connect blue wire marked positive thermostat to + side wire of thermostat using 22-18 GA stranded wire. Connect other blue wire to the other thermostat lead-using minimum 22-18 GA stranded wire. POWER SUPPLY o INJURY OR PROPERTY DAMAGE . This furnace is designed for negative ground 12 volts DC only. DO NOT attempt io alter lurnace for a positive ground system or connect the f urnace directly to 120 volts AC. Damage to furnace components will occur and warranty will be voided. Use a minimum of 1B GA wire to minimize voltage drop. Furnace must be installed so electrical components are protected from water. To make electrical connections see wiring diagrams. For best furnace performance when power supply is from a converter equipped with a charging port, wire converter to furnace parallel with battery. This provides consistent voltage to-furnace, increasing component life, filtering power surges and AC spikes' Some models are shipped with a lield harness connections with 12" wire leads on a terminal block. AII units are supplied with a power switch which when turned off during servicing will remove power through furnace wiring. Switch must be in the ON position for furnace to operate. The direct high voltage spark ignition generates a radio lrequency that could cause interference with other microprocessor-based equipment. Locate equipment at least five feet (5') from furnace locaiion. lf this distance cannot be maintained a shielded high voltage lead can be ordered. See parts list. THERMOSTAT INSTALLATION ELECTRICAL CONNECTIONS A "ou,o* PROPERTY DAMAGE - iE '1 1 17 Thermostats are not supplied. To purchase a thermostat rated for 12VDC or 24VAC, Minimum 1 AMP rating, they can be ordered through Atwood. See Parts list. Be sure all electrical power has been disconnected lrom the air conditioner, furnace, and the power supply. The thermostats are very sensitive. HANDLE WITH CARE AT ALL TIMES. Pick a dry area where air circulation is good. Do not install the thermostat where there are unusual heating conditions: such as direct sunlight, heat producing appliances (television, radio, wall lamp, etc.) or a furnace or air conditioner output registers. Locate thermostat 48" to 54" above main living area iloor on an INTERIOR wall when possible. EXTERIOR wall location must have a 3/4" spacer between thermostat and exterior wall. Follow manufacture's installation instructions provided with thermostat. OPERATING INSTRUCTIONS A wnnrurruc FIRE OR EXPLOSION Do not operate furnace while vehicle is in motion or being towed. The entire piping system must be maintained within a range of 10 to 14" WC when all appliances are in operation. Test gas connections for leakage with a leak test solution. STATIC PRESSURE TEST . During initial firing of this furnace, a burn-off of excess oils remaining from manufacturing process may cause smoking or fumes for 5-10 minutes. NOTE: if furnace should lock out, the blower will go off in 3 minutes and remain off until unit is reset by reactivating the thermostat. . STOP! Read Users lnformation Manualsupplied with furnace. '1 Before furnace is connected, piping systems must be tested to be leak free. The test must maintain air pressure of a least 6" of mercury or 3" PSI for at least 10 minutes. . 2. ' 3. 4. ' 5. 6. 7. B. Turn the manual valve (if so equipped) or the valve at the outside LP tank to the "OFF"" position DO NOT force. NOTE: This furnace is equipped with a valve shut-off switch with switch in "OFF" position. Gas will not flow to burner nor will the furnace operate. Turn switch to "ON" position. Set thermostat above room temperature to begin blower operation. A slight delay will occur before the blower comes on. Allow blower to run for 1 minute for combustion chamber purge cycle. lf blower does not come on go to shut down and contact your dealer or a Iocal recreational vehicle service agency. After 1 minute, the blower may not be running at this time, move thermostat lever below room temperature. Wait approximately 2 minutes for blower to go otf. Open manual shut-off valve (if so equipped) or the valve at the outside LP tank. Correct operation characteristics depend on the valve being positioned fully open. Never attempt to operate with a valve partially closed. Turn shut-off switch to "ON" position. Set thermostat lever to desired setting. lf set above room temperature, blower will come on. Allow 30 seconds for main burner to light after blower comes on. This furnace is equipped with an ignition device which automatlcally lights the burner. DO NOT try to light the burner by hand. lf burner does not light, repeat Steps 1 through 5. lf after three (3) attempts with no ignition, go to shut down and contact your dealer or a local recreational vehicle service agency. Do not continue to cycle furnace through thermostat in an attempt to get ignition. To Shut Down 1. 2. . Special tools required to take casing static pressures. Please refer to Engineering addendum when installing the {urnace. This will provide you with allowable maximum case static pressures with each possible variation of duct configurations. The addendum is available from you Atwood Field Service Representative or by calling Atwood Service. Reducing the number of duct turns and stretching the ducts will increase airflow and reduce static pressure. Adding ducts or increasing the discharge (hard duct) system will also reduce static pressure. You must follow the manufacture's recommendations and specifications for optimum performance and proper operation. IGNITION CONTROL DIAGNOSTIC CODES The following charts give the diagnostic codes given by the ignition control when faults are present. . A soft lockout is a condition that is timed and will make additional attempts to correct the problem. A hard lookout requires resetting the thermostat or turning the power switch oJf, then back on. oJ STANDARD 3 TRIES FOR IGNITION CONTROLS FAULT lnternal Circuit Board Failure Limit Switch/Airflow Problems Flame Sense Fault lgnition Lockout Fault DIAGNOSTIC CHART LED INDICATION Steady On, No Flashing 1-Flash With 3-Second Pause 2-Flashes With 3-Second Pause 3-Flashes With 3-Second Pause LOCKOUT Hard Soft Hard Solt 2.STAGE 3 TRIES FOR IGNITION CONTROLS Set the thermostat to lowest setting, move lever to "OFF" position. Turn manual shut off valve (if so equipped) to the "OFF" position. Do not force. SYSTEM CHECKS A wannrnc FIRE OR EXPLOSION Never check for leaks with an open flame. Turn on the gas and apply soapy water to all joints to see if bubbles are formed. PROPANE GAS PRESSURE TEST The furnace and any individual shut-off valve must be disconnected from gas supply piping system during any pressure testing of system at test pressures of more than 1/2" PSl. Note: (on LD models control ts not vtstble DIAGNOSTIC CHART FAULT LED INDICATION Low lnout voltaoe 1-Flash with 3 second oause lonition failure 2-Flash With 3-Second Pause Open hiqh limit 3-Flashes With 3-Second Pause Stuck Sail Switch 4-Flashes With 3-Second Pause lonition fault 5-Flashes with 3-second pause LOCKOUT Sofl Soit Soit Hard Hard THIS PAGE INTENTIONALLY LEFT BLANK. CETTE PAGE EST INTENTIONNELLEMENT VIDE. WIRING DIAGRAMS/DIAGRAMMES DE CABLAGE l!: roNmoNcolreu r-i LITIT SUTCH N,CJ INTERRUPTEUR DE FIN cAUTlox: Do NOT HlrcT{OIELECTRIC HrGH VoLTAGETEST) THIS UNITAflER INSTIUTION, TO DO SO MY CAUSE COMPONENTOMGEANDVOIDS WARNry OF FURMCE. UNI 1M% FIRE CHECKED / NE PAS FAIRE UN ESSAIDIELECTRIQUE fiESTA UUTETENSION) CECI POURMTENIMiNER L'ENOOMMAGEMENT DES COMPOSANTS ETANNULER UGAmTIE OE LfPMEIL DE FOUMAEE, APPffiEIL AYANT SUBI UNE VER]FICAIION PREVENTIVE CONTRE LlNCENOIE A 1OO% TISEEN GME: SURCETAPPMEILAPRESLINST4hIION. A 85.IV WIRING AND LADDER DIAGRAMS DIAGRAMMES EN ESCALIER ET CABALAGE 85-IV D'ALLUMAGE BLO/ SOUFFL, TH CODE o AB.ltl9E, M -l lr E*88;833 & IEE 9sEE ssgg SsEE ssEfr 'ii.'i'iE fuL WRES TOUS ES NE 18 AWG *LEs Sfr UNLES OBERWSE SPECIFIED/ OE 18 AWG SAUF $ AreMENI ouE I I II [email protected] I NOE:I NOt +F @lGrU wREs S SUPPL|.D w fl frE ppLrNcE wsr sE REPwro, n vusr ar aepuceowrx I#$nHii"" qEMRQUE.St L UuNGAFMPFMTREUn\GoFA- u\ DES CABLES oRtqMLxELs FouNtsavEcLpMEtLrcfmEREMpucE. LDo]f L enE AEc uN MTeRhu oE cABqGE AyN UNE 85.IV-LD WIRING AND LADDER DIAGRAMS DTAGRAMMES EN ESCALIER ET CABALAGE 8s-tv-LD r* Ei EC >4 Ltm[ swrcH N.cJ INTERRUPTEUR DE FIX DE COURSE NF -I* lell.rr{t6MMr.^kiN -dutr^m^&oeiEile 1522,2334 LD WIBING AND LADDER DIAGRAMS DTAGRAMMES EN ESCALTER et cAaaLace Lo $22,2ss4 COMMNDE DALLUMAGE 2 ETAPES LIMIT SWITCH N,CJ INTERRUPTEUR DE F'N DE COURSE NF ilUTbN: rc SO NOT BLrcT OIELECTRIC H GH VoLTAGE EST) mR 6 FUMG, TN S UNtr MY GUSE @MrcNEM OMAGE NDVOIOESWARM NSTMTIoN. To UNT 1@% FIRE DO CHEC& X& Ef, @E I NE P6 FARE UN ESS DIELECMOUE ITBT A IAUTE TENSION) SUR CET PPtr[ MEs L1N$MTIoN. cEct@Rur EFUNERLENWMGEMEM Es coMPNm F NNUERUMtE DE LppaRErL E u FolRNAtsE. FPARETL AYANT suBtuNEERtFtcAnd SPE6IFIE lBE P*vENTtvE coNTRE LINCEND|EA 1@%. 1522,2334 WIRING AND LADDER DIAGRAMS 893s,8940 DTAGRAMMES EN EScALIER er cAelLnce fi22,2334 10 z------L 6\ \__, a\>-(9 @@ I / da \t),6 /A #M@--, M v\-(D: (g l"/--__-\" {k2 a4--@ __2_l \:{ r!!) v\ -B B@ ^(' \9/ ,-\ \.s/-rF lt *E%@ '-ru? PARTS LIST/LISTE DES PIECES Category Cat6gorie Art. Breaker, Circuit Disioncteur 1 Tiile Titre P/N Doors Portes 1 2 36043 4 33754 33756 351 01 351 02 35385 34238 33741 361 29 37228 E 33620 6 33854 351 05 33856 35384 361 30 33749 33801 351 04 7 lfl @ IJ, ao CIRCUIT BREAKER/ON-OFF SWITCH DISJONCTEUR/INTERRUPTEUR MARCHE ARRET CIRCUIT BREAKER/ON-OFF SWITCH 3401 5 DISJONCTEUR/INTERRUPTEUR MARCHE ARRET 3401 Br0leurs I 33847 37125 37126 37128 37129 37652 36942 37388 381 02 34555 CIRCUIT BREAKER/ON.OFF SWITCH DISJONCTEUR/INTERRUPTEUR MARCHE ARRET CIRCUIT BREAKER/ON-OFF SWITCH DISJONCTEUB/INTERRUPTEUR MARCHE ARRET ASSY BURryER HEAD COMPLETE ENSEMB, TETE DE BRULEUR COMPLETE DOORASSY DELUXE, 02 1.PK ENSEMB. PORTE, DELUXE 02 1.PK DOORASSY DELUXE, 04 1-PK ENSEMB. PORTE, DELUXE 04 1-PK DOOR ASSY DELUXE, 22 1-PK ENSEMB. PORTE, DELUXE 22 1-PK DOOR ASSY DELUXE, 23 1-PK ENSEMB. PORTE, DELUXE 23 1-PK DOOR ASSY DELUXE, 32 1-PK ENSEMB. PORTE, DELUXE 32 1.PK DOOR ASSY DELUXE, 44 1-PK ENSEMB. PORTE, DELUXE 44 1-PK DOOR ASSY DELUXE, 47 1-PK ENSEMB. PORTE, DELUXE 47 1-PK DOOR ASSY DELUXE, 34 1-PK ENSEMB. PORTE, DELUXE 34 1-PK DOOR ASSY DELUXE, 36 1.PK ENSEMB. PORTE, DELUXE 36 1-PK INNER,8.5, DOOR HINGE CHARNIERE PORTE, 85, INTERIEURE 85/89 RECESS PAN ASSY 02 1-PK ENSEMB. CUVETTE ENCASTREE 85/89 02 1-PK .1-PK B5iB9 RECESS PAN ASSY 23 ENSEMB. CUVETTE ENCASTREE 85/89 23 1.PK 85/89 RECESS PANASSY04 1-PK ENSEMB. CUVETTE ENCASTREE 85/89 04 1 -PK 85/89 RECESS PANASSY32 1.PK ENSEMB. CUVETTE ENCASTREE B5iB9 32 1.PK 85/89 RECESS PAN ASSY 34 1 -PK ENSEMB. CUVETTE ENCASTREE 85/89 34 1-PK 85/89 RECESS PAN ASSY 47 1-PK ENSEMB. CUVETTE ENCASTREE B5IB9 47 1-PK 85i89 RECESS PAN ASSY 48 1.PK ENSEMB. CUVETTE ENCASTREE 85/89 48 1-PK 85/89 RECESS PAN ASSY 22 1.PK ENSEMB. CUVETTE ENCASTREE B5IB} 22 1.PK ASSY 85-II, DOOR LATCH, N/S ENSEMB. LOQUET PORTE, 85-II, N/S DOOR ASSY STANDARD, 02 1 -PK ENSEMB. PORTE, SIANDARD, 02 1-PK DOOR ASSY STANDARD, 04 1 -PK ENSEMB. PORTE. STANDARD. 04 1.PK DOOR ASSY STANDARD, 22 1-PK ENSEMB. PORTE, STANDARD, 22 1.PK DOOR ASSY STANDARD, 23 1-PK ENSEMB. PORTE, STANDARD. 23 1-PK DOOR ASSY STANDARD, 32 1.PK ENSEMB. PORTE, STANDARD, 32 1-PK DOOR ASSY STANDARD, 34 1 -PK ENSEMB. PORTE, STANDARD,34 1-PK DOOR ASSY STANDARD, 34F 1-PK ENSEMB. PORTE, STANDARD,34F 1-PK DOOR ASSY STANDARD, 40 1-PK ENSEMB. POBTE, STANDARD,40 1.PK DOOR ASSY STANDARD, 43 1-PK ENSEMB, PORTE, STANDARD,43 1.PK 12 IJ' o o o o o J J J I 6t rO 00 X 34012 3401 3 Burners = (o Ir (\t F (r) ro @ rO (oI lO l', fit co ao ol (\t t.., @ X 1t, 6l o) @ co 14, X ro rO c, 6t AI ro o q o (\lI c) c, a{ (\l ol G) X X X x ro rO GO X x X X X X x X X X X X X X X X X X x X X X X X X X X x X x x x X x X X x x x X X x X x x x X X X X X x x x X X X X x X X X X X X Y X X X X X X x X X X X X x X X X X X X X X X X X X X X X x X X X X x X X X X X X X X X X X X X x X X X X X X X X X X X X X x X X X X X X X X X X X X X X X x x X X X Y x X x x X X X x X X X x X x X X x x x X x X X x X X X X X X X X X X X x x X X X x X X X X x X X X X X X c) $I Category Cat6gorie Title Titre P/N Art. (t -l ro o AI |n N lo ro co o o DOOR ASSY STANDARD, 44 1 -PK ENSEMB. PORTE, STANDARD,44 1-PK DOOR ASSY STANDARDI, 47 1+K 33755 ENSEMB. PORTE, SIANDARD, 47 1-PK DOOR ASSY STANDARD, 48 1-PK 33800 ENSEMB. PORTE, STANDARD,48 1-PK PLATE, DUCT COVER, 4 INCH 31361 PLAQUE, COUVERCLE DE CONDUIT,4 POUCES 34237 Ducting 9 Canalisation I ,l 12 IJ '1 5 6 Electrode i 18 Elements 19 E16ments 34033 37958 LLLtvrLt\ I vv/E nAUCt I IO_ZC ASSEMBLAGE, ELEMENTAVEC EVECUNTION yvELU, ELEtvtEt\ M/trAt-tAUU I J.l _35 34450 X X 37959 Fittings, Pipe Tuyauteries, conduits 4SSEMBLAGE, 20 X X X x X X X X Y X X X X X X X XIX X X x x x X X X X X X XIX x X X X X X X X x X x X X X X x x X X X X X X X X X X x X x X x X Y X X X X X X X Y x X X x X X X x x X X XIX X x X X x x X X xx X X X X X X X x x x x x X X X X x Y X X Joini General Parts PiEces g6n6rales lgniton, Controls AIlumage, commandes X X X X X X x X X x x X X x X X X x X X X X X X x X X X X X Y X X x X 25 37600 x X X 26 38304 27 37410 28 37411 29 34512 JOINT, CONDUITE DE GAZ X X X X X X X X X X X X X X X X X x X X X x x X X X X X X x X X X X X X X X X X X 341 X X X X x X X X X X X X IX x X x X XX X X X X X X X X x X X X X x X X X X X I 35 ,-*ll an II U9I UV IVIUUI\ I, TLAD I IU JUPPORT, MONTAGE CC DSI, PLASTIQUE 13 X X X X X x REPLA'E- TROUSSE, ALLUMAGE UNIVEBSFI CC \r I , rvru r \Jn Drtrtru (/ul\ I HUL z5 IAGE oe TROUSSE, CONTROLE DE VITESSE DU MOTEUR 2 ETAPES X X X .A X X X 31 501 x x X TROUSSE, MONTAGE VERTICAL HOUSING, BLOWER BACK 85.IV 37605 BOITIER, DOS SOUFFLANTE 85-IV HOUSING, BLOWER 85-IV 32 37606 BOITIER, SOUFFLANTE 85-IV ao 34696 KIT, DSI BOARD 2-STAGE TROUSSE, REMPLACEMENT 2 ETAPES CARTE DSI X X X 046 al X x x X PRISE, 85/89, S/O ENTREE DE GAZ X X XIX X 31 _35 JOINT, MOTEUR 85-IV X X X X I ] X 24 X l CONN, MALE, 3/B X 3iB GASKET, EXHAUST WALL 37956 JOINT, PAROI D'ECHAPPEMENT I.OAM TAPE, SOLIMIDE, 112X32 34551 RUBAN MOUSSE, SOLIMIDE 112X32 23 X X X X x xlx XIX Jl _35 rleMeur RvEc EvAcuATtoN @ X ELBOW, MALE, 3iB X 3/8 BRASS 31 043 COUDE, MALE, 3/B X 3/B LAITON 31 Gasket /trAHAU5l r', tt) @ X AqSEMBLAGE, elruerurRvEC EVACUATTON 31_35 vvELU, ELETV|EI\ l N a) (\l X 6-25 16-25 rD (t ol C' (llt X ro o o J <l I x X I 6t N to rJ:) lo 6 6L, @ X 1 o J 6l (\t I co 16-'5- rvLLv, rf, e) X z il\ul-l ELECTRODE, ENSEMB. CHF8, AVEC PLOMB ELECTRODE, CHFl ASSY 37057 ELECTRODE, ENSEMB. CHFl WELD, ELEMENT WEXHAUST 34449 ASSEMBLAGE ICTITrur EVEC EVACUATION I X X TOP/BOfASSY PLATEADAPTER EX_ ENSEMB. BOITE DE RALL. ADAPTATEUR DE PLAQUE ELECTRODE, CHFS ASSY WLEAD -- I X ADAPTATEUR, CONDUIT, 2 POUCES ASSY ADAPTER PLATE 85 )37745 ENSEMB. PLAQUE D'ADAPTATEUR 85 HAUT/BAS 7 )37868 Electrode t, I x ENSEMB., ADAPTATEUR DE BOITE DE BALLONGE KIT, FLEX ADAPTER PGTE 34438 TROUSSE, PLAQUE DE L'ADAPTATEUR FLEX BOTTOM PLENUM PLATE SMALL 36277 PETITE PLAQUE PLENUM INFERIEIIRF tEn, uuu 36688 ^u^T o lo N (\l (, I X ADAPTEH, DUCT,4 INCH 10 31474 ADAPIATEUR, CONDUIT, 4 POUCES ASSY EXTENSION BOX ADAPTER 11 331 50 ENSEMB- ADAPIATEUR DE BOITE DE RALLONGE ASSY EXTENSION BOX ADAPTER 37878 l @ c) u) x X o o o o o J J J = ao I (r) X X X X X CategorY Cat6gorie P/N Art. (') ro N lt o co ., 34530 Motors Moteurs eo 38554 "'-- vvLLLvILv'" l?1 ?t^R,:? MOTOR, 2 STAGE XX lx lxi r-i --- l_ I co co (v) I I I I :f g, (\l c) G' (\l co X 1 X X X X x X X x x X X x x xlxlx X x x l ; i-iI ", xl X x X MOTOR, 2 STAGE 37964 MOTEUR,2 NIVEAUX I flB CO CoriecrglBi&qqleE Etq2 vlll tqt- JttI 6l J ln N 6r rO o (o d) lf, N N N lr, ro lI, t, lr! to I x x }RACKET, DSI AUXI LIARY PLA9].I-CI-'LAN I I(JUtr 36 U PORT. DSI AUXILIAIHE. dAr' llFOLD, w/R B5iB9-lll 37 37392 )ot I ECTEUR w/R 85/89-lll JIFOLD. OUTLET LD2 344 l5 ]OLLECTEUR, PRISE LD2 -,^I..IItr.)I D FXTENDED 85 LD2 3B 34406 Collecteur rn lft ao 345tt3 Manifold o N (o to Title Titre o J o o o o o J J >lq 3le' X MOTOR, 8525-31 37697 MOTEUR 8525.31 x X X X MOTOR,8535 37698 MOTEUR 8535 37696 MOTEUH 85'] b-'IU l,37604 sUl-l-UFl 37603 37602 37646 42 43 Orifices A;iliaac 37801 nlg 31 265 I Switches, Sail lnterrupteurs a ailette Thermostats Tharm6siats ]'"? I =, 3' Eifri xri ,)z x x TROUSS!' qrurrlylo'1v1 . onrrrce, X X x XIXIX x X X X X X X X x x x X oRlFlcE, #52. 0.0635 HOLE X XIX x X x X x x X x x x x X X X X X xlxlx X x x X x Y X X X X SWITOH, sAIL 36680 INTERRUPTEUH A AILtr I I tr. U+U UNYI^V TTIERMO--STNT: STAGE DM/RVP,WI]. ^ 49 38535 THERMOSTAI.2 NIVtrAU urvr/nvr uLrrv AA 38452 rF{ERMos-I4I,!El-i9l}1P,T"=Y,}Nr 51 52 oc lg ^^ y4LYFIEL\+?,iY5)l-^,,, 000 BOBINE. I-{trNITLAUEIVILII VALVE SIDE OUTLET, 38604 31 VANNE.PW 31150 -ou, ?iibGs; F'{tsiinrennre vnnne tz vcc BRACKETI/ALVE, 2 STAgE. ... 54 38436 SUPPORI. VANI\tr. Z I\IVE^U^ z srnoE, l2vDC colLs x x XIXIXlX x x xlx xlx X X X XIX X x x xlx x x x x \, x I I x X X x X X X x x X X X X X X x X x X 38602 I VaNNE.2 E, 12v-Dc l 'uuo' [fil lvSlE co-llq ?.I'Y="?Yl=3Y";'i"" lu ADAPTATEUR 1 x x X X X X x x l x X x x x ilnrvE,NlvEAUx'uuo- 55 I I l2vrllcoll XIT. VNI-VE SIDE OUTLET, 12VDC X I RRUN X X '- [99 Iq! x x X #56, 0.0465 HOLE 38453 THERMOSTAT. Event, 6chaPPemeil x x X +fr:Hffi:iffi*?,*rylrlE-.,h CHALTUH strULtrIVIEI\ I' UL^I'" Vent, Exhaust X x x x ORIFICE, #1.45MM 37580 ORIFICE. #1 .45MM SWTCH, r-rrtf rT 36TXV11, L190 TOD 7022 INITEtr}PI IPTFI IR FIN DE COURSE 36TXYI! 47 50 Valves Vannes x X u^oL oRlFlcE' THOU #5b, u u+oc 280 X X x X r c e. # 1 25M M, u KS D o=-a .z5vllvl. xlx xlx x polCi usnor oexrnnr oRlFlct, #l x X rrrro,rOn wALL ASSY r x x x ilBr. * oRtFlcE, #54 o.o55o HOLE 31267 oRlFlcE, TROU #54. 0 u55u oRlFrcE, #51. 0.0670 HOLE 32285 ORIFIOt, I HUU trC I. U.VU 31 lnlerruDteurs fin de course [Ti' ' PUR,POSE ;LNTI,TP TIZ II'ICH OENERAL 31257 Switches, Limit t'-l glgs, y ' BRACKETJ','OTOR RETAINER LARGE :: :;;;;; otrTtrNl ltr ntr MoTEUR. MOYEN r \ +q I' nc t ctru' "- X x e-BAcrerMorg5pT3rlE^TS,Hr,.r.,, 4i X X X MOTOR,8516-20 X ^ .,^^ '' '"" X D'AlR u'nuutustutn t'" 14 X x x X x Y x Category Cat6gorie Art. Title Titre P/N (oI lo @ = |l o (\l ol lo o |I: 6 I o o o o o J J J ASSY PANEL, BURNER ACCESS LD2 ENSEMB., PANNEAU, ACCES BRULEUR LD2 ASSY VENT 3I8LDz 59 34422 ENSEMB., EVENT 3I8LD2 ASSY VENT 5I8LD2 34423 58 34421 X X ENSEMB. EVENT 5/B LD2 60 37891 ASSY DRAFT SHIELD 5/8 X ENSEMB., PARE-VENT 5/8 30503 Wheels Roues Wiring C6blaqe 61 331 28 62 331 26 63 30229 30231 30233 30234 64 36290 37987 15 X I X I Io d) 6a I N ro a J o,l $I rt fit (', 6t o J tlF:' (t l4) @ lO X X x X X X X X (\l x X ASSY DRAFT SHIELD 3/B 37890 ENSEMB.. PARE-VENT 3/8 AD5Y, UNAF I !iHIELU LM 3/8 ENSEMB., PARE-VENT LM 3/B KIT, COMBUSTION WHEEL 85/89 TROUSSE, ROUE COMBUSTION 85/89 KII, BLOWER WHEEL & CLAMP 85 TROUSSE, ROUE ET BRIDE SOUFFLANTE 85 KII, WIRING HARNESS 85DC TROUSSE, FAISCEAU DE CABLAGE 85DC KII, WIRING HARNESS LD TROUSSE, FAISCEAU DE CABLAGE LD KIT, WIRING HARNESS 2-STAGE TROUSSE, FAISCEAU DE CABLAGE 2 NIVEAUX KIT, WIRING HARNESS 85/89 LD TROUSSE, FAISCEAU DE CABLAGE 85/89 LD ASSY FIELD PLUG 85-IV ENSEMB, PRISE D'INDUCTION 85.IV ASSY FIELD PLUG 2STAGE ENSEMB., PRISE D'INDUCTION 2 NIVEAUX I al o rJ) N rO Io rO ol ln tO G) lo o 6 00 6 o @ (i) rO (D X X x X X X X X X X x x X X X X X X X x X x x X X X X X x X x x x X X X X X X X X X X X X X X X x X X X X BLANK' THIS PAGE TNTENTTONALLY LEFT VIDE' CETTE PAGE EST INTENTIONNELLEMENT Num6ro de brochure 30090 /ilrAtwo.d Fo u rn a ise s . 851 6, 8520, 8525, 9531, 9535 Atwood Mobile Products luc "3{3i1":',ifi[:, Moddles Atwood Mobile products 8516-LD, 9520-LD, 9525-LD, 8531-LD, 1120 North Main Street . Elkhart, lN 46514 E.-U:800-546-5759 Ganada a E-U : BOO_B2S_4328 8535-LD 1 522, 2334, 1 522-LD, 2334-LD Manuel d'installation technique Effectif le 10/10 A AVERT..EMENT Eviter les blessures corporelles possibles ou la mort Le moddle de cette fournaise a 6te certifie pour |instailation dans des v6hicules recr6atifs ters que ra fournaise usi, categorre ilr. Suivez res instructions d'installation pour vous assurer que la fournaise fonctionne U.ne installation, un ajustement, une alt6ration, un entretien ou une reparation mal effectu6s peut causer des dommages mat6riels, des blessures ou la mort. Reportez_vous aui instructions d'installation annule la garantie de la fournaise. appareil. L'installation et I'entretien doivent 6tre effectu6s par un sans danger. Ne pas installer la fournaise seron res instructions A L,INSTALLATEUR AU : CONSOMMATEUR: A 18 MODELES DIMENSIONS POIDS Les synboles reli6s A la s6curite vous alertent des dangers personnels potentials. Respectez tous les messages de sEcurite Eviter toute blessure potentielle ou la mort manuel du propri6taire fourni avec cet INDEX SPECIFICATIONS SYMBOLES DIALERTE DE EANGER A le installateur accr6dite, un centre de servie ou le fournisseur d'e gaz. LAISSER CE MANUEL AVEC L'APPAREIL CoNSERVER CE MANUELAUX FINS DE REFERENCE FUTURE A lre*nssEMENr d'installation eUou DISTANCE MINIMALE DES COMBUSTIBLES INSTALLATION ET CODES DE SECURITE .18 .18 EMPLACEMENT GENERAL DE LA FOURNAISE Eviter toute blessure potentielle ou les dommages mat6riels .19 .19 COUPUREDUMURINTERIEURDE EEVENTLD INSTALLATIONDEL'EVENTLD .... ....,,.,...,20 zqNES DE CALFEUTRAGE POUR UTNSTALLATION VERTICALE CANALISATION nvennssEMENT .,,..,..2O .,..,,...20 OPTIONS DE INCENDIE OU EXPLOSION ,.....,2O oEcxaRceMINIMALEREeutsE ...........20 SYSTEMESDECANALISATION FLEXIBLES ....,.,,...,...21 Si l'information continue dans ce manuel n'est pas suivie A la lettre, un incendie ou une explosion pourrait survenir, causanl SYSTEMES DE CANALISATION DURE AU des dommages mat6riels, des blessures corporelles ou m6me la mort POUR VOTRE SECURITE QUOI FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ . Eteignez toute flamme nue. .18 DOOR SIDEWALL CUTOUT INSTALLATION DE LA PORTE rr,trse EN GARDE SOL , . . . , .21 DECHARGEHoRIZoNTALEoUVERTICALE .... ...,...,...21 DECHARGE DE LA BoiTE DE RALLoNGE .....,...,21 PLAQUED'ADAPTATEURFLEXIBLE ..,.,,..21 PROPANE ..,...,.22 CONNEXION DE GAZ : CONNEXIONS ELECTRIQUES . o Evacuez toutes les personnes du v6hicule. Fermez l'alimentation en gaz du contenant ou de Ia source de gaz. Ne touchez aucun interrupteur 6lectrique, n,utilisez aucun t6lephone ou radio qui se trouve dans le v6hicule. N9 d6marrez pas le moteur ou le g6n6rateur 6lectrique du v6hicule Communiquez avec le fournisseur de gaz le plus proche ou un technicien en entretien et reparation accr6dit6 pour faire r6parer I'appareil. Si vous 6tes incapable de rejoindre un fournisseur de gaz ou un technicien en entretien et r6paration accr6dit6, contactez le service d'incendie le plus proche. Ne mettez pas en marche I'alimentation en gaz jusqu,d ce que la ou les fuites de gaz aient et6 r6par6el. L'installation et l'entretien doivent 6tre effeciu6s par un technicien en entretien et r6paration accr6dit6, un centre de servie ou un fournisseur de gaz. .. TABLEAU DES DIMENSIONS DU ,........,.22 CONDUCTEUR , , . , .22 . ..,..22 INSTALLATIONDUTHERMOSTAT ...,.,.,.,22 INSTRUCTIONS D'EXPLOITATION .... .. , . ,2g Pourmettrehorsfonction..... .....2s ALIMENTATION ELECTRIQUE o . . TEST DE PRESSION DU GAZ PBOPANE TESTDEPRESSIONSTATIQUE o , , . , .23 ..,.,23 CODES DE DIAGNOSTIQUE DE LA COMMANDE D'ALLUMAGE 23 3 ESSAIS STANDARD POUR LES COMMANDES D'ALLUMAGE 23 3 ESSAIS 2 ETAPES POUR LES COMMANDES D'ALLUMAGE . DIAGRAMMES DE DIAGRAMMES DIAGRAMMES DIAGRAMMES DIAGRAMMES CABLAGE.... EN EN EN EN ESCALIER ESCALIER ESCALIER ET CABLAGE LD 1522,2334 , , , .10 ESCALIER ETCABLAGE 1522,2334, . . . . . .10 DessindesPiBces Pidces Liste des 17 .23 ...........9 ETCABLAGESs-IV ...... ...... 9 ETCABLAGESs-IV-LD ......... 9 .. .......11 . .12_15 ce qui est indiqu6 dans la sp6cification - air repris minimal. Ne pas satisfaire aux exigences d'air repris minimal annule la garantie de la fournaise. Lorsque les fournatses sont tnstall6es avec un d6gagement minimal, un 16po2 additionnel d'air repris doit 6tre fourni au c6t6 de la soufflante de la iournaise, ou un d6gagement de 2 po d la pleine longueur et hauteur du c6t6 de la soufflante doit 6tre maintenu. SPECIFICATIONS MODELES 8520-lV 8525-lV 853'l-lV 8535-tV 85'16-LD 8520LD 8525LD 8531 - LD 8535LD Entr6e BTU 16,000 20,000 25.000 30,000 34,000 Pression statique gaine .20" cE ,10'CE .10" cE .10'cE .10" cE lntensit6 de courant 6leciriorre (A\ 4.6 4.6 7.6 I .t) 9.8 Watts 55 55 91 91 118 Alimentation 6lectrique (Volt CC) 12 1a 12 12 12 85161V Moddles Air repris 80 80 in2 recommand6 Air repris 80 in2 80 in2 b5 rn- 65 in2 65 in2 65 in2 Entr6e BTU Pression statique naine lntensit6 de courant 6lectrioue (A) Watts Alimentation 6lectrique Uolt CC) Air repris recommand6 Air repris minimum - (CE Colonne d'eau) . Caisson Porte Event LD Standard 30 lbs 32 lbs dommages mat6riels. Un emplacement d'installation inappropri6 pou!-raii conCuire la fournaise dr produire une pression n69ative affectar: I arr de NE PAS installer la fournaise sur un materiau qui emp6che le retour d'air, comme un tapie ou tout autre mat6riau mou comme le vinyle. NE PAS installer la fournaise otr un d6gagement entre elle et des combustibles ne peut otre maintenu. NE PAS modifier la fournaise de quelque fagon qu'il soit. NE PAS alt6rer la fournaise en vue d'un systdme de mise d la terre positif. NE PAS faire un essai di6lectrique de la fournaise sauf si le systdme d'allumage 6lectronique (carte de circuits-imprim6s) a 6t6 d6connect6. NE PAS utiliser le chargeur de batterie pour alimenter la fournaise du moddle DC en courant 6lectrique mCme pendant un essai. NE PAS utiliser un courant CA de '120 volts avec les moddles Faible 15,000 lev6 22.O00 Faible 23,000 Elev6 34.000 1O'CE 1O'CE. 10" CE .10'cE. 4.8 10.2 t.5 13.2 58 122 79 158 12 12 1) 12 80 in2 80 in2 80 in2 80 65 in' 65 in' 65 in' 65 in' in2 DC. NE PAS utiliser la zone de l'armoire de la fournaise comme compartiment d entreposage. NE PAS ventiler la fournaise avec un systdme de ventilation servant a ventiler un autre appareil. NE PAS ventiler la fournaise d une plate-forme ext6rieure encloisonn6e. NE PAS utiliser pour un chauffage temporaire d'immeubles ou de structures en construction. Prot6ger les mat6riaux de construction contre la d69radation qui peut Ctre caus6e par l'6chappement du gaz de carneau. Prot6gez les composants 6lectriques de la fournaise de l'eau. Les compartiments doivent 6tre ferm6s lorsque I'appareil fonctionne. Profondeur Largeur Hauteur 16-112" 19-'U4" 5" 7-318" 18" 9-1t4" 1t4" POIDS Fournaise Caissonn6 Une installation, un ajuslement, une aiteratlon .in eniretien ou une 16paration mal effectuds peut causer ies blessi'es ou des Aor=*r,asEMENTs cRtrteuEs coNcERNANT = DIMENSIONS Tous les moddles La fournaise doit etre install6e et ventil6e selcn ces instructions' combustion ou la ventilation d'autres appareils 2334 1522 Modiles # . . L'INSTALLATION 65 in2 minimum in2 80 in2 AVERTISSEMENT INTOXICATION OXYCARBON EE 2 Etapes 31 lbs 33 lbs DISTANCE MINIMALE DES COMBUSTIBLES Les planches de oarquet. murs et mat6riaux de construction conbustiblgs simitaires doivent Ctre fournis d la pleine longueur et largeur de l'appareil' Horizontal haut et Arridre 1" Bas 3/1 6" c6t6s 1/2" Vertical haut et c6t6s 1/2" Arridre 1" Bas 0" (extr6mit6 de la Plaque coulissante) INSTALLATION ET CODES DE SECURITE E-U et Canada - suivre tous les codes locaux et d'6tat applicables - en I'absence de codes ou rdglements locaux, reportez-vous aux normes courantes des : . V6hicules r6cr6atifs ANSI ,A1 19.2/NFPA 501 C . National Fuel Gas Code ANSI 22231 eUou CAN/CGA 8149 Codes d'installation o Norme f6d6rale sur la s6curit6 et ia construction de maison mobile (Federal Mobile Home Construction & Safety Standard), titre 24 CFR' partie 3280. ou lo!'sque cette norme n'est pas applicable, la norme des installations de maisons pr6fabriqu6es (sites de maisons pr6fabriqu6es, communaut6s et pr6parations), ANSI 4255.1 et/ou CAN/CSA-2240 s6ries MH. Matsons mobiles . Code national de l6lectricite au sol (Ground National Eleclr cal Code) ANSI/NFPA No. 70 eUou CSAC22.1 . Caravanes de parc ANSI 1 19.5 ll est n6cessaire d'avoir un espacement de 1/4 de poucesjusqu'a Ia canalisation en dedans de 3 pieds de la fournaise sauf si des gaines en vinyle cercl6es homologu6es UL sont utilis6es. Tout le mat6riel de canalisation devrait 6tre qualiii6 d'utilisation continue 2r un minimum de 200'F' . . o La distance avec les combustibles concernent particulldrement le bois contreplaqu6 ou des mat6riaux de construction similaires autour de la fournaise (a savoir la fournaise ne devrait pas Ctre plac6e sous des meubles ou dans une armoire orl des vetements ou tout autre mat6riel pourrait se trouver.) L'appreciation du rendement de la fournaise est une appr6ciation thermique d6termin6e en vertu de conditions d'utilisation continue, ind6pendamment de toute installation. Le taux d'efficacit6 est donn6 a un minimum de77%.le taux d'efficacit6 r6el peut 6tre sup6rieur' L'air repris est fourni d travers des ouvertures situ6es dans le caisson de la fournaise. Tous les passages de l'air repris doivent rester d6gag6s afin que la fournaise puisse fonctionner ad6quatement. Reportez-vous 2r la distance minimale requise pour les planches de parquet, murs et mat6riaux de construction combustibles similaires. La ou les grandeurs totales des ouvertures d6gag6es de I'air repris doivent Ctre moins que EMPLACEMENT GENERAL DE LA FOURNAISE . . . 18 lnstallez la fournaise e travers un mur ext6rieur NE PAS installer la fournaise ir proximit6 de pidces basculantes, glissantes, des portes ou autre projection qui pourrait bloquer l 6chappement de la fournaise. Placez la fournaise vers le point milieu de la voiture coach pour des applications de fournaise simples. L'installation doit etre faite de sorte d pouvoir acc6der d ra fournaise en cas de,r6paration. Ne pas satisfaire d ces exigences entrainera des co0ts de main-d'euvre additionnels qur seront-la responiabilite de I'installateur. NE PAS installer un 6vent dans les endroits oi une proiection ou des ouvertures de porte arrivent d 6"ou moins de I'ouveriure du tube de l'6vent. NE PAS installer la fournaise dans un endroit ori des cAbles, conduites ou autres objets g6neront l,installation ou le fonctionnement de la fournaise. NE PAS installer la fournaise sur un mat6riau qui emp6che le retour d'air, comme directement sur un tapis ou tout autre mat6riau mou (comme le vinyle). Si vous devez installer Ia fournaise sur un tapis ou un mat6riau mou, installez-la sur des crampons, ou sur un panneau en bois ou en m6tal s'6tirant sur toute la largeur et profondeur de la et en la plagant d une distancJminimale des combustibles. f9yr1ai9e NE PAS utiliser des nettoyants d base de p6trole ou d'agrume sur les preces en plastique, car des dommages pourraient surv6nir. l\or=*rssEMENr EMPOISONNEMENT AU MONOXYDE DE CARBONNE Bien ajuster le bouchon de tirage pour emp6cher Ie monoxyde de carbone d'entrer dans la voiture coach. INSTALLATION DE LA PORTE . . ' . MISE EN GARDE Blessures corporelles PA: )E louverture d6pa"Ii- permettre aux languettes d" l, forrn"i"e d" de coupure de la paroi lat6rale durant l,instaliatron avant que la porte ne soit install6e et les languettes pench6es en avant. Faire pas manipuler et se frotrer conire tes bords en tote pour ?I:lji:-11? evtter tes Dlessures corporelles. La porte standard ou la porte deluxe peuvent Ctre utilis6es seules ou avec un cadran encastr6 optionnel. Voir les instructions fournies avec le cadran pour le irou de d6coupe et les instructions de montage. fournaise- doit toujours €tre install6e d niveau (d'avant en arridre, et 13 d'un c6t6 d l'autre) pour pr6venir que de I'eau peneiie a |,int6rieur. Pour.pr6venir ra p6n6tration de moisissure d I'int6rreur de Ia voiture coach, appliquez un produit d,6tanch6it6 de type RTV. lg cadran de porte doit 6tre 6troitement alust6 pour pr6venir une fuite d'eau. Les portes sont congues pour permettre r'6vacuation de I'eau aussi bien dans les installations horizonlales que verticales. Un non Lmptacement de I'ensemble de ventilation est important pour avoir rn" Uonn" 6vacuation des fum6es et un fonctionnement approprie de la fournaise. l_"-"l"1d.oreille (C) t6che sur t,ensembtL de bouchon de tirage, Termez la porte (A) et tirez I'ensemble de bouchon de tirage (D) vers lavant jusqu d ce qu'il s'appuie contre l,6cran (B). Ouvrez la porte et serrez l'6crou ir oreille. Fermez Ia porte et assurezvous que le bouchon de tirage est contre l'6cran de Ia porte. ,!:jl:?l !: A AVERTISSEMENT ,Bc INTOXICATION OXYCARBONEE Sceller ad6quatement la porte et les systdmes de ,entilation pour emp6cher le monoxyde de carbone d,entrer dans la voituie coach. NE PAS extraire de I'air de combustion de la zone habitable. NE PAS ventiler I'air d,6vacuation dans la zone habitable ou une plate-forme encloisonn6e. . o DOOR SIDEWALL CUTOUT * Epaisseur du mur ext6rieur recommand6e O,,a 1-112", 2-112" maximum cOrr cnUcHr Figure 2 rB-r . 2. 1 d6passent la paroi ext6rieure. L'extr6mit6 de la boite de commande doit affleurer le revOtement externe de Ia voiture coach (installation VERTICALE _ Ia connexion de gazdoit 6tre sur la partie inf6rieure). Appliquez un produit d'6tanch6it6 de type RTV ir toute ra bride arridre du cadran afin de cr6er un joint 6tanche d i,eau. Fixez en ins6rant le cadran de porte dans les lanquettes de Ia fournaise d travers des encoches sur le cadran J"Lrt". La prise d'admission et la plaque coulissante Ooirlit Ctre en position ferm6e et la bride du cadran de porte a I'int6rieur Oe la plaque coulissante. lnserez six languettes de montage d travers les fentes fournies dans le cadran de porte. le cadran O"oit etie serr6 contre le carsson et un produit d,6tancheite RTV doit 6tre appliqu6. Courbez les languettes de sorte a ce qu'elles afftJtirent le cadran de porte, en alignant les trous des langueites avec les fentes dans le cadran de porte. lnstallez'12 vis de montage. NE pAS d6former le cadran. Le cadran de porte doit 6tre 6troitement aluste conire la paroi lat6rale pour pr6venir une fuite d'eau. Remplissez les fentes de languette avec du calfeutrage aprds avoir fix6 Ie tout avec des vis. 10 de.produit d'6tanch6it6 autour du cadran de porte et i:,::"^=l:}"U9,:nt rnspectez vtsuellement le cadran de porte afin de vous assurer qu,il est bien scel16. 11. Fixez les pattes de montage au sol pour l,installation horizontale. pour res appareils verticaux, utilisez un support de montage vertical et des vis d auto-filetage pour retenir la fournaise au sot (tes ta"ngueites qui se trouvent sur la boite de commande peuvent Ctie utilisEes pour fixer la fournaise). Pour connaitre Ie No de pidce ae f, t.ur.e rJrticale, voir la liste des pidces. 12. Serrez la porte avec les pidces de fixation fournies. ^3. 4. 5. C Figure f irez la fournaise vers l,avant jusqu,d ce que les languettes de montage 1 ^ 6. NE PAS faire un trou trop grand car cela pourrait causer une fuite d,eau. A orr*rssEMENT 7. 8. 9. EMPOISONNEMENT AU MONOXYDE DE CARBONNE Bien ajuster le bouchon de tirage pour emp6cher le monoxyde de carbone d'entrer dans la voiture coach. 19 VERTICALE ZONES DE CALFEUTRAGE POUR L'INSTALLATION COUPURE DU MUR INTEREUR DE L'EVENT LD Figure 4 Vous devez calfeutrer toutes les zones illustr6es . Autour de Ia prise d'admission de gaz rouge au complet (C)' .AutourducOt6noiraucomplet,lesextr6mitesdelaplaqueoielle . . s'accouple 2r la t6le m6tallique <B>' elle entre dans la Autour de la conduite de gaz au complet, d l'endroit oi <D>' gaz de prise d'admission dt L" long des joints soud6s <A> des deux coins inf6rieurs du caisson ior" rnEt"rriqir" et oi la bride de la porte couvre Ia plaque coulissante' OPTIONS DE CANALISATION DECHARGE MINIMALE REQUISE Zone de d6charge requise 24 Poz. Moddles 851 6, 8520 36 Po' 8525, 8531 8535 1522 aca 48 Po' 36 Po' 48 Po' ^ Tous les moedeles utilisant les options de d6charge du haut ou du bas Toutes les installations verticales 48 po' 48 po2 Figure 3 Coupure du mur | int6rieur A B c 2-316 t- lz J- 1t2', I trou du diamdtre * Epaisseur du mur recommand6e 0" 1o 2-112" une fuite d'eau' NE PAS faire un trou trop grand car cela pourrait causer INSTALLATION DE L'EVENT LD 1. Rep6rez la coupure du trou de l'6vent tel que appel6' ;. p"i*, r trou de de 3_112" de diamdtre d travers la paroi lat6rale de la voiture coach. fournaise' 3. Retirez l'6vent et I'anneau de l'6ventdedelalaparoi, 4. i..J*= r, fournaise du i6t6 arridre la fournaise' en alignant le trou de la oaroi au trou de l'6vent situ6 dans 5. ffipiiq*;;; p;oouii J;etancrreit6 d l'arridre de l'anneau de l'6vent et e la base du bouchon de l'6vent' l'indication HOT sur le dessus des 6. - inttuf "= f;"nt.rble d'6vent avec sur le c6t6 droit des installations Figure 5 au bon Une bonne installation de la canalisation est essentielle ton.ti*n"m"* de la fournaise. Lorsque vous installez les conduits'de Itiii"Ll a"i ,rt6riaux qualifi6s d'utilisation continue d un minimum f in.irf frtions horizontales et HOT ,"rtiarf L'anneau de l'6vent doit glisser d I'int6rieur du tube Fixez 2r la paroi avec quatre (4) vis "t. de I'air de combustion OLJmlssion 7 . g. - 200"F. planches de Reoortez-vous a la distance minimale requise pour les rnut"ri"r* de construction combustibles similaires' ;;iq;;i, de bh"oua ouverture de canalisation de 4 pouces fournit une zone po2 additionnels de zone de 12 un Fournissez io'. &;h;t;" de canatisation non fermable pour chaque registre fermable utilis6. comme une L'utilisation des canalisations de 2" n'est pas consid6r6e de decharge minimum' La canalisation dans oL. "rig"n"". ientilee sans air repris, telle que des zones de d'air non des de retenue, n'est pas consid6r6 comme une satisfaction non fournies. minimal de 1LLnsemUte d'6vent doit maintenir un chevauchement de i/4"rw le tube d'evacuation et de '112" minimum sur le tube d'air du mur' combustion. NE PAS exc6der l'6paisseur maximale les pattes sur Fixez la fournaise au sol avec deux (2) vis, d travers utilisez un support de pour verticaux, appareils les caisson. du i,uriier" au ,onirg" vertical et des vis dr auio-filetage pour retenir la fournaise peuvent lof (r"Jirngr"ttes qui se trouvent sur la boite de commande pidce de de cir" ,tif ite"-. pour fixer la fournaise) Pour connaitre le No la trousse verticale, voir la liste des pidces' ,;;"i ;;;il;i;;;i, ;"ilf*il;; ;;;il; iJr"roit exigences de d6charge minimum' 20 . . 6. 7. Ajustez l'tnstallation de canalisation pour obtenir une augmentation de I'air d 100"F-1 30'F. Les fournaises install6es d l'horizontale - utilisant des options de conduits lat6raux - doit avoir minimum un conduit de chaque c6t6 du caisson (d savojr un condurt d gauche et un 2r droite). DECHARGE DE LA BoITE DE RALLoNGE SYSTEMES DE CANALISATION FLEXIBLES Dimensions de cououre au sol Lorsque vous concevez des systdmes de conduits flexrbles : Evitez les coudes courts ou les conduits 6cras6s. Etirez tous les conduits et acheminez-les directement aux orifices de sortie, en gardant Ia quantit6 et les angles des coudes au minimum . 1. 2. 4 5. lnstallez la fournaise sur le joint; assurez-vous que le joint reste en place. Une canalisation additionnelle pourrait 6tre n6cessaire pour maintenir une bonne pression statique ou tel que d6sir6. A B c D E 18" 1t2" 5" 16', 1t4" INSIDE WALL Retirez les plaques d'6jection des orifices de sortie d6sir6s. Attachez un adaptateur de canalisation ir chaque ouverture en ins6rant une bride par-dessus le caisson, verrouillant la languette dans la fente du caisson et tournant l'adaptateur d g0'. Attachez et fixez des conduits flexibles de quatre pouces aux adaptateurs. Acheminez les conduits d l'emplacement d6si16 d l'intdrieur du VR, fixez aux registres. Une canalisation additionnelle pourrait 6tre n6cessaire pour maintenir une bonne pressron statique. -/--' A ' ',._,-'- SYSTEMES DE CANALISATION DURE AU SOL Lorsque vous concevez des systdmes de canalisation dure : Une taille r6duite de la canalisation causera une limitation des hautes temp6ratures. Une taille accrue de Ia canalisation causera un d6bit d'air inad6quat d partir des registres. Lorsque la canalisation dure est de 1-112" de profondeur, une canalisation flexible additionnelle pourrait Ctre n6cessaire pour maintenir les exigences d'installation statique de canalisation. NE PAS installer les registres du sol 2r moins de 2 pieds des ouvertures d'air repris. Voir l'option de canalisation des zones sup6rieures et inf6rieures du caisson. Ces options peuvent Ctre avec des installations de canalisation flexible ou dure. La canalisation dure peut 6tre scell6e d l'aide de trousses optionnetles contenant un joint et une plaque de p16num. Voir la liste de pidces. . . . Figure 7 . . o '1. 2. . DECHARGE HORIZONTALE OU VERTICALE 3. 4. 5. 6. 7. Dimensions de d6coupe au sol A 8-112" B U 9-1tr" 5-1t4" D 1t4" Une plaque de pl6num pourrait 6tre utilis6e pour l,installation de d6charge sup6rieure ou inf6rieure. Une boite de rallonge du caisson ajoute 6 pouces de profondeur au caisson de la fournaise. Pour faire une commande, voir la liste de pidces. Retirez trois 6jecteurs de l'arridre de la fournaise. Placez Ia boite de rallonge avec le joint en mousse contre la fournaise, en vous assurant que les trois ouvertures sont comprises dans la boite de rallonge. En retenant la boite de rallonge en place, fixez-la avec deux vis d t6le m6tallique d'112" non fournies. Serrez la plaque de pl6num par-dessus la coupure. Placez le joint sur Ie la plaque de pl6num. lnstallez la fournaise sur le.joint; assurez-vous que le joint reste en place. Serrez la boite de rallonge au sol avec des vis d t6le m6tallique d'1t4" ou des agrafes. Une canalisation additionnelle pourrait 6tre n6cessaire pour maintenir une bonne pression statique ou tel que d6sir6. PLAQUE D'ADAPTATEUR FLEXIBLE Figure 6 Les appareils peuvent 6tre install6s en tant que systdmes de d6charge inf6rieure/sup6rieure ou systdmes de d6charge inf6rieure verticale. 1. 2. 3. Retirez la plaque de d6charge inf6rieure / sup6rieure; ces options de canalisation doivent Ctre connect6es ir un systdme de canalisation. Assurez-vous de sceller tous les joints lors de I'utilisation d,un joint et d'une plaque de pl6num pour les configurations de canalisations dures. D'autres m6thodes de scellage de la fournaise au sol sont acceptables tant que le d6gagement et les joints d'6tanch6it6 satisfont aux exigences de d69agement et de temp6rature. Serrez lla plaque de pl6num par-dessus la coupure au sol. Si un joint et une plaque de pl6num ne sont pas utilises, scellez la fournaise au systdme de canalisation dure en vous assurant que le joint d'6tanch6it6 est 6tanche d l'air. Placez le joint sur le pl6num par-dessus la fente du trou. Figure 8 Un adaptateur flexible pourrait Ctre utilis6 pour fournir plus de flexibilit6 pour I'alignement de l'ouverture de d6charge sur les systdmes 2r canalisation dure. Ce systdme peut 6tre utilis6 sur tous les moddles install6s horizontalement ou verticalement fournissant une canalisation de I'arridre de la fournaise sans l'utilisation de conduits lat6raux. L'utilisation d'une trousse de plaque de montage flexible est disponible. Voir la liste de pidces. 1 2 21 Retirez trois 6jecteurs de l'arridre de Ia fournaise. lnstallez les adaptateurs dans chaque ouverture. du ruban en mousse Placez la ptaque de l'adaptateur flexible avec sont dure en vous assurant que les ouvertures ru 3. "".ii" align6es. "rruriration TABLEAU DES DIMENSIONS DU CONDUCTEUR - Maximum '10% de chute de tension serrez la plaque ir la canalisation d l'aide 4. En retenant la plaque en place, plate' de vis ou d'agrafes afin de la garder 5. rntGrr", troiJuoaptateurs de ionduii dans la plaque de l'adaptateur flexible. de la fournaise d la plaque de 6. niir.n", la canalisation flexible sur les deux i ;;;t"t";t fl"rible et fixez en place la canalisation extr6mit6s. ctre necessaire pour maintenir 7. un" ""n"ii.rtion additionnelleoupourrait tel que d6sir6' maftu . ,n" laiton situ6 sur le c6t6 droit Connectez la conduite de gaz au raccord en de la fournaise. ou sur le c6t6 droit a Certains moddles auront des raccords 2r l'arridre I'ext6rieur du caisson. que les les filetases de tuvaux males' autres compos6 scelleur ,r"."td. a a"f f"i repouss6, sont-trait6s avec unPAS mettre un compos6 NE r6sistant ir l'action du gaz propane (LP))' repouss6' collet a raccords rl"tt"r, sur les 6vas6 Jes pour retenir le raccord en laiton et l'6crou uilr[lt NE PAS fixezia conouite de gaz au raccord en laiton tourner l'ensemble de robinet 12. (12VCC) conducteur SAE (en pieds) de Ia source au MISE EN GARDE DOMMAGES MATERIELS Uonn" pression statique CONNEXION DE GAz PROPANE - faible^tension ou d Cette connexion est destin6e ir une batterie d Ne pas connecter 2r 120 ou 240 volts cA' J*iu.i Jii""i.eulement. p6les n6gatif-s reli6s d Ia masse de Cette fournaise est conque pour des de.modifier la fournaise pour essayer PAS bc."rLment.'NE a la masse ou de connecter reti6es positives p0les ,uoiiun svstdme de aux L iournaise directement 2r 120 Volts CA Des dommages plus fournaise se produiront et la garantie ne sera iir"ri. i;;;;;;;;t-Gious ;;;;.;;[;;li o*ilJil; il; valide. tension' la chute de Utiiir". ,n cAble de cal 18 minimum pour minimiser composants i, i"ri*i.! J"lt 6tre install6e de fagon d ce que les prot6g6s de l'eau Pour faire les connexions il;i;;;;;nt 6lectriques, voir le diagramme de cAblage' p"ri,r* pltf*mance-optimale de la fournaise lors-que I'alimentation d amen6e' orifice LtL"trGr"'prori"nt d'un convertisseur muni d'un Ceci a la fouinaise paralldlement 2r la.batterie "aul"."r" "f*"rtisseur fournitunetensionconstanteaLatournaise,prolongeantladur6edevie cA' filtrant les sautes de puissance et les pointes ;; ;;p;;;.i", de faisceaux de C"rt"in.'moOefes sont exp6di6s avec des connexions de jonction' bloc un 12"sur de passe-fils des ;;;;;";" un interrupteur de courant qui' i;;t L; appareils sont fournis avec le courant a travers le c6blage coupera l'entretien, rli.ir" "t,iiliorrant ioit 6ire mis en position oN (MARoHE) BOUCHON DE de la fournaise. L'interrupteui afin que la fournaise puisse fonctionner' une fr6quence i;rttu.rg" direct par etincelle a haute tension g6ndre iurr"t dei interferences avec d'autres 6quipements pl."..l'6quipement 2r cinq (5) pieds au munis d,un microprocesseui. un ,oint J" i, tortnaise. Si cette distance ne peut 6tre maintenue' command6 Voir la liste de blindage en plomb a narte ientron peut Ctre ;;i;;;l"p*;i pidces. Figure 9 . Une prise N.P.T de 1/8" est accessible pour la connexion du manomdtred,essaisurl'ensembledurobinetdegazafindetesterla pression. d-e 3/S" est fournie au Une connexion du raccord 2r collet repouss6 d6bit gazeux pour connecter niveau de l'entr6e du roOinet Oe conti6le du d'alimentation de de gaz d ta tournaise La taille du tuyau ifrf une pression de fournir de afin aoequate ctre ooii fournaise la oaz de sous des conditions iE ir::w.c].' c"n" Jression doit 6tre maintenue gaz en fonction' de appareils les tous ayant de debit maximum en du gaz de la Retirer la plaque coulissante et Ia prise d'admission . 'r""iut.. # . . .- fournaise. prise d'admission de gaz (NE lns6rez la conduite de gaz d travers la PAS COUPER). prise d'admission de gaz d Connectez la conduite de gaz d travers la. imm6diatement devant le robinet de caisson o" contr6le du d6bit gazeux' i'io'*uit" li;iffi;;;u 1. 2. 3 4. A Acheminez Ie cAblage au c6t6 gauche de lafournaise-. I'alimentation 6lectrique' Connectez le cAble rouge au cdt6 positif de Conn""t". le c6ble noiiau c6t6 mis a Ia masse de l'alimentation 6lectrique. au cdble + lat6ral Connectez le cAble bleu marqu6 positif du thermlslat cat tt- t6' de torsade cdble le utilisant en thermostat du d l'aide iuutre cdble Uteu-a i'autre fil de sortie du thermostat 6onn".t", d'un c6ble torsad6 de cal22'18' ALIMENTATION ELECTRIQU E l'utilisation d'un Atwood Mobile Products recommande fortement d 169ulation de .i.r"ir.."riZiecironique teiai soiioel avec une alimentation ;;;;.i;;. du moteur et des a;"apermettra ru pioi*guti';n de la dur6e de vie applications de convertisseur lin6aire commandes 6lectroniques types. ",-JLra"J"t INSTALLATTON DU THERMOSTAT voulez acheter un Les thermostats ne sont pas fournis' Si vous 1 A m.inimum' vous th;;";i;f ;r;liie oe tz vcc, ou 24 VCA,deavec la liste de il;";l;;il;"nJ"r. prt l'intermediaire Atwood voir CONNEXIONS ELECTRIQUES pidces. A BLESSURES coRPoRELLEi'ou . . que le courant 6lectrique a 6t6 d6connect6 de l'air la lonJittnne, iournaise et I'alimentation 6lectrique' AVEC SOIN EN Les thermostats sont tres sensibles' MANIPULEZ-LES TOUT TEMPS. est bonne' Choisissez une zone sdche oir la circulation oir les conditions de endroit un dans pas thermostat Ie rl;intiJr", directe du soleil' des lumidre la ;h;;ff;;;;;.1 inhabituelles lampe murale' etc ) radio' o" iiereuition, ].o[:r"il" "n"r",t fournaise ou d'une unit6 d'air oe sortie d'une L*r"r-uort orr*r,.sEMENr oo*u49E9',4IEI'=t' aux fins d'entretien' Etiquetez tous les fils avant de les d6connecter peuvent c6blage de erreurs Les .caus.er ,yn IT:PTt:."^?l fonctionnement une fois inappropri6 et dangereux.-V&it[' le bon I'entretien termin6' I'entretien' Oeconnectez le courant 6lectrique avant d'effectuer ,'io"" d";ir"ti". il";;';A;U conditionn6. plr*, f" thermostat e 48".d 54" au-dessus du sol de la zone habitable possible' lorsque INTERIEUR mur prin"iprf" sur un Ie rirEnriuns doivent avoir une entretoise de 3''1 er:'e ["r thermostat et le mur ext6rieur' #r" 22 . Suivez les instructions d'installation du fabricant fournies avec le thermostat. pression d'air d'au moins 6"de mercure ou 3 pSl pendant au moins 10 minutes. INSTRUCTIONS D' EXPLOITATION A L'ensemble du systdme de tuyauterie doit 6tre maintenu en dedans d,une plage de 10 il 14" CE lorsque tous les appareils sont en fonction. Testez les connexions de gaz pour vous assurer qu'il n'y a pas de fuite avec une solution pour essai d'6tanch6it6. avennssEMENr INCENDIE OU EXPLOSION TEST DE PRESSION STATIQUE Ne pas faire fonctionner la fournaise pendant que le v6hicule est en . mouvement ou est remorqu6. . . Lors de I'allumage initial de cette fournaise, un br0lage des r6sidus exc6dentaires d'huile issus d la suite du processus de fabrication pourrait causer de la fum6e ou des vapeurs pendant 5 d 10 mjnutes. REMARQUE : Si la fournaise est verrouill6e, la soufflante s,6teindra au bout de 3 minutes et restera 6teinte jusqu'ir ce qu'elle soit r6initialis6e en r6activant le thermostat. Veuillez vous reporter d l'addenda d'ing6nierie lors de I'installation de la fournarse. Ceci vous fournira les pressions statiques de tubage maximales permises avec chaque variation possible de configurations de conduits. Vous pouvez vous procurer l'addenda de votre repr6sentant de service r6gional Atwood ou en appelant le service de Atwood. R6duire le nombre de rotation et d'6tirement des conduits augmentera le d6bit d'air et r6duira la pression statique. L'ajout de condults ou l'augmentation du systdme de d6charge (conduit dur) r6duira 6galement la pression statique. Vous devez suivre les recommandations et sp6cifications du fabricant pour avoir une performance optimale et un bon fonctionnement. ARRETEZ! Lisez le Manuel d,information a l,intention de I'utilisateur fourni avec la fournaise. 1. 2. E 7. 8. Mettez la vanne manuelle (le cas 6ch6ant) ou la vanne situ6e d l'ext6rieur du r6servoir LP d la position (OFF) (ARRET). NE pAS forcer. REMARQUE : Cette fournaise est munie d'un interrupteur d,arr6t de Ia vanne avec I'interrupteur en position (OFF) (ARRET). Le gaz ne s'6coulera pas pour parvenir au brOleur et la fournaise ne fonctionnera pas. Mettez I'interrupteur d la position (ON) (MARCHE). R6glez le thermostat au-dessus de la temp6rature de la pidce afin de d6marrer la soufflante. Quelques instants s,6couleront avant que la soufflante se mette en marche. Laissez la soufflante fonctionner pendant 1 minute pour le cycle de purge de la chambre de combustion Si la soufflante ne d6marre pas, mettez I'appareil hors fonction et communiquez avec votre marchand ou avec I'agence locale de servrces des v6hicules r6cr6atrfs. Aprds 1 minute, la soufflante pourrait ne pas fonctionnera ce stade-ci, d6placez le levier du thermostat a une temp6rature inf6rieure d la temp6rature de Ia pidce. Attendez environ 2 minutes pour que Ia souffiante s'arrCte. Ouvrez la vanne d'arr6t manuelle (le cas 6ch6ant) ou la vanne situ6e it I'ext6rieur du r6servoir LP. Les bonnes caract6ristiques de fonctionnement d6pendent de la position de la vanne, 2r savoirsi elle est completement ouverte ou pas. N'essayez jamais de faire fonctionner I'appareil avec la vanne partiellement ferm6e. Mettez I'interrupteur d'arr6t d la position (ON) (MARCHE). R6g1ez le degr6 du thermostat tel que d6sir6. Si le thermostat est 16916 au-dessus de la temp6rature de la pidce, la soufflante se mettra en marche. Attendez 30 secondes avant que le br0leur principal ne s'allume suivant le ddmarrage de Ia soufflante. Cette fournaise est 6quip6e d,un dispositif d'allumage qui allume automatiquement le brOleur. NE pAS essayer d'allumer le br0leur d la main. Si le br0leur ne s'allume pas, r6p6tez les 6tapes 1 d S. Si au bout de trois (3) tentatives l'allumage ne se produit pas, mettez I'appareil hors fonction et communiquez avec votre marchand ou avec l'agence locale de services des v6hicules r6cr6atifs. Ne confinuez pas d faire fonctionner la fournaise d travers le thermostat en vue de provoquer un allumage. CODES DE DIAGNOSTIQUE DE LA COMMANDE D'ALLUMAGE Les tableaux suivants fournissent les codes de diagnostics donn6s par la commande d'allumage Iorsque des anomalies se produisent. . . 2. yn verrouillage souple est une condition qui est chronom6tr6e et qui fera des tentatives additionnelles pour corriger le probldme. Un verrouillage dur n6cessite la r6initiallsation du thermostat ou une mise hors tension suivie d'une remise en tension. 3 ESSAIS STANDARD POUR LES COMMANDES D'ALLUMAGE TABLEAU DE DIAGNOSTIC ANOMALIE D6faillance de la carte de circuit imorim6 interne Hrooleme avec l'interrupteur de fin de course /d6bit d'air Anomalie de d6tection de flamme Anomalie de blocage de I'allumaqe INDICATIONS DEL Sur ON tout le temps, pas de cliqnotement 1-clignotement avec pause de 3 secondes VERROUILLAGE Dur 2-cilgnotements avec pause de 3 secondes 3-clignotements avec pause de 3 secondes Dur Souple Souple (aprds 1 heure) 3 ESSAIS 2 ETAPES POUR LES COMMANDES D'ALLUMAGE (Remarque : sur les moddles LD la commande ne peut 6tre vue) TABLEAU DE DIAGNOSTIC ANOMALIE Faible tension d'entr6e chec de I'allumage Pour mettre hors fonction '1 Des outils sp6ciaux sont requis pour prendre les pressions statiques de caisson. Dispositif de commande maximum ouvert lnterrupteur a ailette bloqu6 Anomalie d'allumage R6glez le thermostat au niveau le plus bas, puis mettez le levier d la position <OFF> (ARRET). Mettez Ia vanne d'arrCt manuelle (le cas 6ch6ant) d la position <OFF> i (ARRET). Ne forcez pas. VERIFICATIoNS DU SYSTEME A av=*rrssEMENT INCENDIE OU EXPLOSION Ne jamais v6rifier s'il y a une fuite en presence de flamme nue. Ouvrir le gaz et appliquer de l'eau savonneuse d tous les joints pour voir si des bulles vont se former. TEST DE PRESSION DU GAZ PROPANE La fournaise et toute vanne d'arrct individuelle doivent 6tre d6connect6es du systdme de tuyauterie d'alimentation de gaz durant tout processus de test de pression du systdme ir des pressions test de plus de .1/2" pSl. Avant de connecter la fournaise, les systdmes de tuyauterie doivent 6tre test6s afin de s'assurer de l'absence de fuite. Le test doit maintenir une 23 INDICATIONS DEL 1-clignotement avec pause de 3 secondes 2-clignotements avec pause de 3 secondes 3-clignotements avec pause de 3 secondes 4-clignotements avec pause de 3 secondes 5-clignotements avec pause de 3 secondes VERROUILLAGE Souple Souple Souple Dur Dur