Download Multitech E Specifications
Transcript
MT100UCC-C2 MODEL OVERVIEW Power Draw MT100UCC-C2 5 volts Cellular call box connection no data (amps) Average Peak TX measured current amplitude (amps) at current (amps) maximum power Total inrush charge measured in MilliCoulombs (mC) Total inrush charge duration during power up (uS) US Cellular 800 Mhz 0.066 0.516 0.568 0.36 193 US PCS 1900 Mhz 0.066 0.686 0.748 0.36 193 Note: Multi-Tech Systems, Inc. recommends that you incorporate a 10% buffer into the power source when determining product load. Peak Tx: The peak current during a CDMA connection transmitting data at max power. Maximum Power: The continuous current during maximum data rate with the radio transmitter at maximum power. Inrush Charge: The total inrush charge at power on. Pinout Specifications 22 Pins Signal Name Logic Level Voltage I/O Description JP2-1 VCC 5.0 PWR DC input power JP2-2 USB DN 3.3 I/O USB data JP2-3 USB DP 3.3 I/O USB data JP2-4 GND GND GND Ground QuickCarrier™ USB-E MT100UCC-C2 Developer Guide