62
/
/
Part # 4 -- Heater & NTC (4)
To separate base from tank (2):
#
#
#
Disconnect J-box ground wire, then pull wires out of J-box.
Pull out inlet hose from sump.
Carefully pull base away from tank and sump.
Pull wires from J-box
Pull out sump inlet hose
HINT:
Its simpler &
quicker to remove the two
water valve screws than to
remove the hose clamp.
HINT: Don’t order duplicate parts when ordering
parts below -- when these parts are replaced,
others are included:
• Heater assy. -- includes NTC, Hi-Limit, flow
switch (& aqua sensor where applicable).
• NTC -- includes Hi-Limit.
Carefully pull base away from tank & sump