Download AT&T Merlin Legend BIS22 Specifications
Transcript
AT&T MERLIN LEGEND Communications System Pocket Reference TM Copyright © 1991 AT&T All Rights Reserved Printed in U.S.A AT&T 555-610-141 Issue 1 August 1991 Ordering Information To order copies of this document: Call: AT&T Customer Information Center on 800-432-6600; In Canada, call 800-255-1242 Write: AT&T Customer Information Center 2855 North Franklin Road P.O. Box 19901 Indianapolis, Indiana 46219-1385 For assistance when installing or programming the system: Call: National Service Assistance Center (NSAC) at 800-628-2888 or your authorized AT&T dealer Notice While reasonable efforts were made to ensure that the information in this document was complete and accurate at the time of printing, AT&T can assume no responsibility for errors. Changes or corrections to the information in this document maybe incorporated into reissues. Trademarks Accunet is a registered trademark of AT&T. AUDIX is a trademark of AT&T. Definity is a registered trademark of AT&T. Magic on Hold is a registered trademark of AT&T. Megacom is a registered trademark of AT&T. MERLIN is a registered trademark of AT&T. MERLIN LEGEND is a trademark of AT&T. MERLIN MAIL is a trademark of AT&T. MLX-20L, MILX-10D, MLX-10, and MLX-28D are trademarks of AT&T. SYSTIMAX is a trademark of AT&T. ERRATA MERLIN LEGEND™ Communications System Pocket Reference 555-610-141 Ignore all references to the small processor module. The MERLIN LEGEND™ Communication System offers only one processor module. This processor module is referred to as a large processor . module in this document. Page 2 Backboard Requirements: References to “Small system” should read “One expanison carrier” and references to “large system” should read “Two expansion carriers.” Pages 7-13 Hardware and software Parameters Table: Ignore the columns headed “Small.” Page 14 Ordering Codes Table: The following Price Element Codes are not valid: Small (Analog) - 6141-CUA Small (Digital) - 6141-CUD Small (Digital) - 6141-24D Page 15 Ordering Codes Table: The following Price Element Code (PEC) is not valid: Upgrade from Small to Large - 6140-USLA Page 31 Memory Sizes: Ignore reference to small processor module. October 1, 1991 Table of Contents Design Benefits Environmental Requirements Control Unit Interfaces Network Interface Requirements FCC Registration DOC Registration Hardware and Software Parameters Ordering Codes Control Unit Modules Adjunct Summary Uninterruptible Power Source (UPS) Backup Times Power Supply Unit Load Requirements ■ Unit Load Calculation Rules ■ Unit Load Rating of System Modules ■ Unit Load Rating of System Lines, Telephones, and Adjuncts System Features Telephone and Operator Console Features Reference Documents 1 2 4 5 6 6 7 14 30 38 48 49 49 51 52 53 56 70 i Design Benefits Modular components allow easy, cost-effective growth in both size and function. For upgrades from the MERLIN® system family of products, all analog MERLIN system telephones, as well as wiring, can be reused. For upgrades from MERLIN II, certain line/trunk and station modules can also be reused. Menu-driven system programming maintains the customer’s command of business operations. Built-in 1200-bps modem allows fast access to the system by customers, AT&T personnel, or authorized dealers from a remote location for system programming and maintenance. Flexible mode of operation saves upgrade costs by allowing system configuration in one of three modes: Key, Behind Switch, and Hybrid/PBX. Connectivity to other systems in the Behind Switch mode optimizes existing resources by permitting the system to work as part of another MERLIN LEGEND™ Communications System, System 25, System 75, System 85, Definity® 75/85, or other communications systems. Also, the system control unit can connect to another system’s control unit by using an off-premises telephone (OPT) line, an analog tie trunk, or a digital tie trunk. Digital 2.048-MHz bus supplies a 64-kbps channel on each of the 216 time slots. 68000 Motorola CPU running at 10 MHz with zero wait states provides fast system performance. Memory data retention saves time by ensuring that system and station programming information is retained for 12 to 30 days, depending on the system configuration, in case of power failure or system shutdown. Integrated voice and data capabilities allow users to converse while transmitting data at speeds up to 64 kbps. DS1 interface can be configured for connection of either T1 or ISDN for basic call control with the AT&T 4ESS PRI service specifications. ISDN S/T BRI protocol supports premier digital multiline telephones (MLX) with superior display capabilities and supports the ISDN 7500B Data Module for the connection of adjuncts. Page 1 Environmental Requirements Control Unit 45 lbs 90 Ibs 135 Ibs Fully loaded basic carrier Fully loaded 2-carrier Fully loaded 3-carrier Mean Time Between Failures 14” W x 23” H x 12” D 25” W x 23” H x 12” D 37” W x 23” H x 12” D 2.1 years (mean or average time the product/system is expected to operate before any type of failure occurs) Mean Time Between Outages 4.0 years (mean or average time the system is expected to operate before a failure affecting more than 25% of stations or lines for more than 15 seconds occurs) Backboard Without SYSTIMAX™ Small system ■ Large system With SYSTIMAX ■ Small system ■ Large system ■ 4’ W x 3’ H x 3/4” D 6’ W x 3’ H x 3/4” D 5’ W x 4’ H x 3/4” D 7’ W x 4’ H x 3/4” D Backboard Mounting Hardware Requirements Wood screws Wood surface Masonry anchors Concrete surface, brick, cinder block Toggle bolts Plaster, plasterboard Sheet-metal screws Sheet-metal surface ■ Hardware should have a combined pullout force of 650 Ibs. ■ When mounting to sheet-metal walls, attach to structural members. Location Within 5 ft of dedicated AC power outlet (1 plug per carrier) ■ Within 1000 cable feet of telephones ■ Heat Dissipation Fully loaded basic carrier Fully loaded 2-carrier Fully loaded 3-carrier 500 Btu/hr 1000 Btu/hr 1500 Btu/hr Power Requirements Basic carrier 117 VAC 2-carrier 117 VAC 3-carrier 117 VAC Page 2 60 Hz ± 5% 3A 60 Hz ± 5% 6A 60 Hz ± 5% 9A Environmental Requirements (continued) Temperature Humidity Range 40°–104°F; 4–40°C (optimum temperature 60°F) 20%-80% relative humidity Ventilation 1” on left side; 1” on right side; 12” above; 12” below Cautions ■ ■ ■ ■ ■ ■ ■ Do not use switch control on AC outlet for control unit. Use approved ground (AC receptacle for 3-prong plug). Do not install control unit outdoors. Do not place control unit near extreme heat (furnaces, heaters, attics, or direct sunlight). Do not expose control unit to devices that generate electrical interference (such as arc welders or motors). Do not place anything on top of carriers. Do not install control unit under any device that may drip fluid, such as an air conditioner. Page 3 Control Unit Interfaces Signaling Channel Rate Audio/ Data Rate Interface Applications ISDN-BRI S/T* Digital switch to MLX telephones 16 kbps (D); 64 kbps (B) Digital switch to ISDN 7500B Data Module 64 kbps (B and D) DS1 Switch to the following services ■ T1 — Emulated tie trunk, loop-start, and ground-start ■ ISDN-PRI services Accunet® switched digital service, Megacom® WATS, Megacom® 800, Software Defined Network (SDN) 64 kbps RS-232C Switch to PC connected to system programming RS-232C port 2400 bps or 1200 bps 2400 bps or 1200 bps Switch to AT&T model 572 printer, PC with CAS, or CAT connected to RS-232C port 1200 bps 1200 bps * Call handling derived from CCITT recommendation Q.931 Page 4 Control Unit Interfaces (continued) Interface Applications ATL Digital switch to analog multiline telephones Signaling Channel Rate Audio/ Data Rate 40 kHz 3003400 Hz Network Interface Requirements Line/Trunk Type Facility Interface Code Network Interface Loop-start 02LS2 RJ11C, RJ14C, RJ21X Ground-start 02GS2 RJ11C, RJ14C, RJ21X Direct Inward Dialing 02RV2-T RJ11C, RJ14C, RJ21X Off-premises telephone 0L13C RJ11C, RJ14C Tie line TL31M RJ2GX T1 04DU9-B 04DU9-C RJ48C/X ISDN-PRI 04DU9-B 04DU9-C RJ48C/X Page 5 FCC Registration Registration Number REN Type AS593M-72682-MF-E 1.5A Multi-function AS593M-72914-KF-E 1.5A Key only DOC Registration DOC Certification No. CSA Certification No. 230-4095A LR-56260 Page 6 Load No. 6 Hardware and Software Parameters Item Allowed lists Number of lists Entries per list Digits per entry Applications CAS CAT CMS Number of lines/trunks (each) Number of agents (each) Number of external alerts (each) Integrated Solution II AUDIX Voice Power-lS II Number of mailboxes (each) Integrated Voice Power Automated Attendant Call Accounting System-lS II System Programming and Maintenance–IS II MERLIN Attendant MERLIN MAIL™ Voice Messaging System Number of mailboxes (each) System Programming and Maintenance–DOS Automatic Route Selection Fully programmable ARS tables Entries per table Entries across all tables ARS patterns Subpatterns per pattern Routes per subpattern Default tables Small Large 8 10 7 8 10 7 1 1 2 28 28 4 1 1 2 28 28 4 1* 300 1* 300 1* 1 1* 1 1 4 1 4 4 40 4 40 1 1 16 100 1600 18 2 6 4 16 100 1600 18 2 6 4 * AUDIX Voice Power-lS II and Integrated Voice Power Automatic Attendant cannot be connected simultaneously. Page 7 Hardware and Software Parameters (continued) Small Large Callback calls in queue 64 64 Calling Groups Number of groups Members per group* Groups per member Delay announcements per system Delay announcements per group Groups per delay announcement External alerts per group Coverage groups per group 32 20 1 32 1 32 1 1 32 20 1 32 1 32 1 1 Carriers † Slots per basic carrier Slots per expansion carrier Carriers per system Total slots available 5 6 3 1 7‡ 5 6 3 17 Coverage Groups Number of groups Senders per group Groups per sender § Receiver buttons per group Groups per QCC receiver 32 56 1 8 30 32 144 1 8 30 Item * QCCs cannot be members. † The processor module must be placed in slot 00 in the basic carrier. ‡ Software limits on the number of lines/trunks and stations usually limit the number of carriers in a small system to 2 and therefore the number of slots to 11. § For Hybrid/PBX systems, when queued call consoles (QCCs) are used, the queue can also be assigned as a receiver but is not counted in the 8-receiver maximum. Page 8 Hardware and Software Parameters (continued) Small Large Data hunt groups Number of groups Members per group Groups per member 32 20 1 32 20 1 Digital data via ISDN 7500B Data Module 24 127 Direct Inward Dialing Number of blocks Number of trunks 2 24 2 80 1 40 1 130 1 56 1 144 16 50 48 50 Direct Station Selectors* 12 16 Disallowed Lists Number of lists Entries per list Digits per entry 8 10 11 8 10 11 DS1 modules 1 3 Item Directories System Directory (System Speed Dial) Number of directories Listings per directory Extension Directory Number of directories Listings per directory Personal Directory Number of directories Listings per directory Fax machines with Message Waiting 16 † † 16 * Two per MLX module; the analog multiline display console has a built-in DSS. † The system can support more than 16 fax machines, but those in excess of 16 cannot use the fax message-waiting indication. Page 9 Hardware and Software Parameters (continued) Small Large Lines/trunks* 24 80 Night Service Groups Members per group Groups per member Emergency Allowed List entries 8 56 8 10 8 144 8 10 Item * † ‡ § Operator Consoles Direct-line consoles (DLCs) MLX-20L™ or MLX-28D™ † BIS-22D, BIS-34D, or System Display Console ‡ QCCs † Combination of DLCs and QCCs Number of consoles per module 6 8 8 4 8 2 8 4 8 2 Paging system ports (loop-start only) 3 3 Park codes 8 8 Personal lines 56 64 Personal Speed Dial § Entries per single-line or 5- or 10-button telephone Entries per system Digits per entry 24 880 16 24 1200 16 Pickup Number of groups Members per group Groups per member 30 15 1 30 15 1 Lines/trunks can be configured as personal lines. Two per MLX module. Two per analog module. Single-line and 5- or 10-button telephones only. Page 10 Hardware and Software Parameters (continued) Item Small Large Pools (trunk groups) Maximum number of pools Maximum number of trunks in a pool 11 24 11 80 Pool buttons 56 64 Ports (not achievable simultaneously) Delay announcements Digital data via ISDN 7500B Data Module Paging Voice and data (physical ports) Voice Announce to Busy stations Voice-mail interface* Total ports † 32 32 24 3 56 28 20 80 127 3 144 127 20 224 Power failure transfer telephones 6 20 * Although the system software supports up to 24 voice mail interface (VMI) ports, all the VMI ports must be in the same calling group, and the maximum number of stations in a calling group is 20. † The large system is said to have a total capacity of 224 (80 CO lines/trunks plus 144 stations). However, these are physical jacks. Each MLX station jack represents 2 logical endpoints (ports). For example, an MLX telephone with a Multi-Function Module (MFM) plugs into only 1 station jack, but the jack supports the telephone and whatever is connected to the MFM (fax machine, answering machine, etc.). The 1 station jack is supporting 2 endpoints. Although it has only 1 jack, the 100D module can serve up to 24 endpoints. Therefore, the entire large system can be configured to connect up to 80 lines/trunks and 255 station endpoints, a total of 335 endpoints. This total of 335 endpoints exceeds the system’s capacity of 216 time slots. If more than216 endpoints are in use at the same time, blocking can occur. Page 11 Hardware and Software Parameters (continued) Small Large Remote Access Number of barrier codes Digits per code 16 4 16 4 Shared System Access (SA) buttons Number of shared buttons per SA 16 16 Stations Total physical jacks Total endpoints 56 56 144 255 1 1 1 1 1 1 56 136 28 16 127 48 24 56 127 144 Item System programming equipment* MLX-20L™ RS-232 port for PC with SPM Modem Telephones Analog multiline without Voice Announce to Busy Analog multiline with Voice Announce to Busy MLX-20L† MLX-10,™ MLX-10D,™ or MLX-28D (with or without ISDN 7500B Data Module or Multi-Function Module) ‡ Single-line * Remote system programming overrides on-site system programming unless an on-site backup or restore procedure is taking place. The system sends a message that a remote connection is established before terminating an on-site system programming session. † Total includes the MLX-20L telephone used for system programming. ‡ An MFM and an ISDN 7500B Data Module cannot be connected to the same telephone at the same time. Page 12 Hardware and Software Parameters (continued) Small Large Traffic Hundred call seconds (CCS) per hour per station 7.0 6.0 Two-party conversations 40 108 Item Page 13 Ordering Codes Component PEC Comcode App Control Unit Small (Analog) Basic carrier and housing Power supply module Processor (small) Feature module (small) 408 GS/LS 6141-CUA Small (Digital) Basic carrier and housing Power supply module Processor (small) Feature module (small) 008 MLX 800 GS/LS 6141-CUD Small (Digital) Basic carrier and housing Power supply module Processor (small) Feature module (small) 008 MLX (3) 800 GS/LS 400 GS/LS/TTR 6141-24D Large 6140-CUL Basic carrier and housing Power supply module Processor (large) Feature module (large) Upgrade from Mll to 6140-UDLA Large (Digital) Cover Processor (large) 008 MLX Feature module (large) MLX-20L telephone (choose one): Black White Expansion cover (zero, one, or two) Page 14 106388614 105743801 105711972 105711998 106064678 403E 391A1 517A23 517A24 517A26 106388614 105743801 105711972 105711998 105628010 105627996 403E 391A1 517A23 517A24 517A21 517A19 106388614 105743801 105711972 105711998 105628010 105627996 105627988 403E 391A1 517A23 517A24 517A21 517A19 517A18 106388614 105743801 106215155 106064660 403E 391A1 517A27 517A25 106388234 106215155 105628010 106064660 16A 517A27 517A21 517A25 105685465 7713DO1A003 7713DO1A264 17A 105685473 106388259 Ordering Codes (continued) Component PEC Upgrade from MII to Large Cover Processor (large) Feature module (large) Expansion cover (zero, one, or two) 6140-UULA Upgrade from Small to Large Processor (large) Feature module (large) 6140-USLA Expansion Unit Expansion carrier and housing Power supply module 61490 Expansion Unit Cover n/a Comcode App 106388234 106215155 106064660 106388259 16A 517A27 517A25 17A 106215155 106064660 517A27 517A25 106388630 105743801 403F 391A1 106388259 17A Line/Trunk and Station Modules 008 (ATL) 61485 105351092 51703 008 MLX 61486 105628010 517A21 008 OPT 61489 106387525 517A28 012 (T/R) 61487 106397631 517E13 100D (DS1) 61491 105461560 517B15 400EM (tie trunk) 8303-200 105311401 517A14 400 GS/LS/TTR 61483 105627988 517A18 408 GS/LS 61481 106064678 517A26 800 DID 61488 105628002 517A20 800 GS/LS 61484 105627996 517A19 400 (with TTRs) 61379 105408892 517B12 408 LS 61482 105512495 517C1 800 LS 61384 105351100 517B4 MLX-10 (black) 3156-02B 105685440 MLX-10 (white) 3156-02W 105685457 7712D01A003 7712DOlA264 Vintage Line/Station Modules Telephones Digital/ISDN Multiline Telephones Page 15 Ordering Codes (continued) PEC Component Comcode App Digital/ISDN Multiline Telephones, continued MLX-10D (black) 3156-03B 105688303 MLX-10D (white) 3156-03W 105688311 MIX-20L (black) 3156-05B 105685465 MIX-20L (white) 3156-05W 105685473 MLX-28D (black) 3156-04B 105688329 MLX-28D (white) 3156-04W 105688337 7712D02A003 7712D02A264 7713D01A003 7713D01A264 7713D02A003 7713D02A264 Analog Multiline Telephones (black) MLC-5 3168-MLC 105515332 7312H01A003 BIS-10 3165-10B 105161061 7313H01A003 BIS-22 316W28 105188809 7314H01A003 BIS-22D 3166-DSB 105630420 7315H01B003 BIS-34 3167-34D 105167027 7317H01A003 BIS-34D 3167-DSB 105630529 7317H01B003 Z7302H01 D-003 Z7303H01 D-003 Z7309H01 C-003 Z7305H01 B-003 Vintage Analog Multiline Telephones (black) 5-Button 3160-111 105217426 10-Button 3161-172 105217509 10-Button HFAI 3161-161 105371942 34-Button 3162-412 103842050 34-Button Deluxe 3162-417 105217715 Z7305H02 D-003 34-Button BIS 3162-BIS 103981965 Z7305H03 D-003 34-Button BIS/DIS 3162-DIS 103981981 7305H04C003 Page 16 Ordering Codes (continued) Component PEC Comcode App Single-Line Telephones Model 7102 Black 3185-MWR 105335285 105330419 Misty cream Model 2500 YMGK (message waiting, recall, touch-tone, desk) Black 3178-NHL 105480578 105480560 Misty cream Model 2500 MMGK (recall, touch-tone, desk) Black 105414130 105414122 105414155 105414148 2500MMG J-003 2500MMG J-215 3101-EBW 105480081 Misty cream Model 500 MM (rotary, desk) Black 2500MM GK-003 2500MM GK-215 3101-EBD Misty cream Model 2554 MMGJ (touch-tone, wall) Black 2500YMGK -003 2500YMGK -215 3101-ETR Misty cream Model 2500 MMGJ (touch-tone, desk) Black 7102A01A003 7102A01A215 105480032 2554MMG J-003 2554MMG J-215 3100-ORD 103870234 Ivory 103870226 Beige 103870267 500MM03 500MM50 500MM60 Page 17 Ordering Codes (continued) Component PEC Comcode App Single-Line Telephones, continued Model 554 BMPA (rotary, wall) Black 3100-ORW 103823498 Ivory 103823506 Beige 103823555 554BMPA -3 554BMPA -50 554BMPA -60 Consoles MERLIN® II System Display Console 61392 105229744 7318H01A003 DSS console (black) 3156-DCB 105685481 604A1-003 DSS console (white) 3156-DCW 105685499 604A1-264 Applications Call Accounting System (CAS) CAS PIus LEGEND Custom Tariff* CAS Plus upgrade CAS/H CAS/H LEGEND 100S CAS/H LEGEND 200S CAS/H Custom Tariff* Call Accounting Terminal (CAT) CAT/B 150S CAT/H 150S CAT/B update (Custom Tariff)* CAT/H update (Custom Tariff)* Call Management System (CMS) 5 1/4” floppy disk 3 1/2” floppy disk Board 1201-DR1 12010 12009 406362244 406158444 406158394 1201-H10 1201-H20 12050 405799255 405799289 405799420 3600-023 3600-024 406478800 406478818 406478792 406478784 36023 36024 1207-100 106496540 106496532 8301-100 106198815 MERLIN LEGEND integrated Solution II AUDIX Voice Power-lS II 1234-VR1 106491608 AVP2.1 for LEGEND 1234-SR1 106491590 LEGEND Integ SW IVP4SS R1 .2 1234-BR1 106491616 IVP4 Board LEGEND 8306-100 106248651 * Consult AT&T or an authorized dealer for other area-specific information. Page 18 Ordering Codes (continued) Component PEC ComcOde App Applications, continued Integrated Voice Power Automated Attendant SAA LEGEND IVP4SS R1 .2 LEGEND IVP4 Board LEGEND Call Accounting System lS II System Programming and Maintenance lS II MERLIN Attendant Hardware Documentation MERLIN MAIL™ Voice Messaging System for the MERLIN LEGEND Communications System Two-port MERLIN MAIL unit Remote maintenance device Four-port MERLIN MAIL unit Remote maintenance device Two-port line card (R2) (upgrade from two to four) 1234-AA1 1234-BR1 8306-100 1201-U12 61496 106491624 106491616 106248651 406478537 106496565 6125-ATT 406221499 106431265 6107-005 406467910 406466193 6107-006 6107-007 System Programming and 61495 Maintenance (SPM) for the MERLIN LEGEND Communications System (MS-DOS*) 406467902 406466193 406464750 106492655 Adjuncts/Adapters System Adjuncts/Adapters Auxiliary Power Unit 9024 Channel service units (CSUs) ESF T1 61416 406467142 9024 2152-ESF 405616293 Cable (8 mod, wire wrp) 21555 Cable (8 mod, 15-pin sub) 21554 Stand-alone wall mount 21545 305010171 -001 406012609 513861312 -505 406012591 513823015 -50 Ft 405970104 380100213001 * Registered trademark of Microsoft Corporation Page 19 Ordering Codes (continued) Component PEC System Adjuncts/Adapters, continued Channel service units (CSUs) 2152-15T 551 T1 L1 Power unit Unit Cord 21530 Stand-alone wall mount 21545 Cordless Telephones Model 5320 62523 Electrostatic discharge (ESD) suppression kits D-181574 D-181589 0-181590 0-181591 0-181593 EMI filter lROB unit — analog multiline* n/a n/a n/a n/a n/a ISDN 7500B Data Module Stand-alone power supply Multiple mounting 7500A upgrade kit Magic-on-Hold® player Modem 2224G 403768179 305-10097001 404242639 KS22911L1 DW4A-SE 103985660 10FT IP 405970104 380100213001 3103-CLS 105543516 CS6300U1 1A-229 DA-5 Digital Voice Announcer IROB unit — MLX* Comcode App 405745811 ANNCRDA-5SL DI 0181574 D181589 D181590 0181591 0181593 Z200A 406106583 343 CA 0A 32918 6XIN 106417447 505A ASSY 32919 0A WD 2164-BDM 105657654 Z7500B-L1 405509852 WP90110 21625 L7 105441166 Z77A 21626 105688501 D182208 21627 3128-010 405143827 DECKMMP/ RCA PR 2224-CEO 105659965 2224C-L1 D/2 105179329 105201891 105201909 105201917 105201933 * Any multiline off-premises telephone must have an appropriate IROB protector at the control unit location and at the off-premises location. Page 20 Ordering Codes (continued) Component PEC Comcode App System Adjunct/Adapters, continued Music Coupler 61398 406143925 PagePac* 6 5323-006 405701277 PagePac 6 Plus 5323-008 405701608 PagePac 20 Power Mate † with three speakers Ring generator unit 5323-005 5323-001 61388 403308026 403308067 105213201 SMDR Printers 475 (80-column, serial) 3330-475 403318942 476 (132-column, serial) 3330-476 403818495 572 (80-column, serial) 3333-572 406152983 Uninterruptible Power Source (UPS) 2403-050 500 VA (15 min) 105610141 ASSYK23395 L3 22052-006 PG PC 22052-000 PG PC6 ADP06 ADP06 129B RING GEN 4758510BR2 4761550BR2 5729500DR 10IN 24035 105610174 Universal Paging Access Module 58500 (UPAM) n/a TAM-B n/a PRS-48 WMT-1A n/a † ZoneMate 9 53505 Dialer unit 405891698 515 UPS005C111 ERG W/BAT005E5 KIT-UPAM 405899972 405742735 405891680 D181900 D181900 D181900 404057911 DIAL UNIT9ZONE CNTL 22050020 Reserve (1 hr) Control unit 405024134 * Registered trademark of Dracon, a division of Harris Corporation † Trademark of Dracon, a division of Harris Corporation Page 21 Ordering Codes (continued) Component PEC System Adjuncts/Adapters, continued 53506 ZoneMate 39 Dialer unit Control unit Comcode App 404057929 39 ZONE SELECT 405024134 CNTL_22050020C External Alerts Loud external ringer 31016A E1CM-type Gray 31019A 103117016 RINGERL1AMP49 102872934 RINGERE1CM-49 102917952 RINGERE1CM-50 Ivory 61211 D-181233 102992252 290A ADPTR 102872934 E1CM-49 102988466 1049A 103938494 CORDD4cH87-25 Bell 61212A 403349962 BELLKS23053 L1 Horn 61213A 403349970 KS23053 L2 Deluxe horn 61223A 406207217 SIG THET4-1 Strobe 61221A 403319197 STROB SCOPE Chime 61222A 405136060 CHMCHBT2 S1 E1CM ringer and parts 290A adapter Ringer Mounting plate Cord Supplemental Alerts Page 22 Ordering Codes (continued) Component PEC Comcode App Telephone Adapters General Purpose Adapter (analog) Multi-Function Module (digital) Supplemental Alert Adapter (SAA) 2301-GPA 103977997 Z1C 3156-MFM 105736474 540A1 2301-SSA 105031199 ADPTR856A Telephone Adjuncts Headset Adapter 3164-HFA 105752042 Headset Adapter 62524 Single-line telephones 4A Speakerphone Power unit 3120-02W 105471304 102139938 Block connector 102434925 Adapter for single-line telephone 102813888 Adapter for multiline telephone 102949013 Transmitter 103971891 Black 103873873 Ivory 103873881 Green 103873899 Beige 103873907 White 103873964 S202A Speakerphone Black Misty cream ADPTR502C-003 ADPTRKS23552 4A PWR UNIT85B1 BLK CON82B-49 ADPTR223C ADPTR2230 IP TRMR680AF-03 LSPK108AA-O3 LSPK108AA-5O LSPK108AA-51 LSPK108AA-6O LSPK108AA-58 3152-008 105721088 105721096 TELS202A003 TELS202A215 Page 23 Ordering Codes (continued) Component PEC Comcode App Telephone Adjuncts, continued S203A Speakerphone Black 3131-008 106058340 MODS203A003 106508365 MODS203A215 106284011 BRKTS203 WL ST 103966396 Z34A Misty cream Bracket Message Waiting Indicator Hands Free Unit (HFU) 31032 3163-HFU 103953790 MODS102A185 Headsets Analog Multiline Telephones Supra* 3122-011 3122-012 3122-013 † StarSet II 3122-001 3122-002 3122-003 3122-004 403350085 HDSTKS22990 L1 403350077 HDSTKS22990 L2 403350051 HDSTKS22990 L3 403241540 HDSTKS22915 L1 403241557 HDSTKS22915 L2 403241565 HDSTKS22915 L3 403350093 HDSTKS23080 L1 * Trademark of Plantronics Corporation † Registered trademark of PIantronics Corporation Page 24 Ordering Codes (continued) Component PEC Comcode App Analog Multiline Telephones, continued StarMate* E 3122-204 403412307 HDSTKS23080 L4 3122-214 403973431 HDSTKS23080 L5P Digital/ISDN (MLX) Telephones StarSet II—StarMate-E 3122-304 405211723 HDSTKS23080 L7 Supra—StarMate-E n/a n/a HDSTKS23080 L8 MLX Telephones—Miscellaneous Add-Ons/Replacement Parts Handsets and Cords Handset (black) n/a 106050065 K2S1-003 Handset (white) n/a 106053408 K2S1-264 Handset, amplified hearing Black White Misty cream 31052 Handset, amplified push to listen Black White Misty cream 31053 Handset cord (9’, black) n/a 105635429 H4DU-003 9Ft Handset cord (9’, white) n/a 105701809 H4DU-264 9’BULK Handset cord (12’, white) n/a 102402609 H4DU-264 12’IP Handset cord (12’, black) n/a 102401445 H4DU-3 12Ft IP Handset cord (25’, black) n/a 105523866 H4DU-3 25’ DSS line cord (2’) n/a 106187545 CORD D8AC-87 105581896 K6S2-003 106248248 K6S2-264 105581904 K6S2-215 106382344 K8S2-003 106382369 K8S2-264 106382351 K8S2-215 * Trademark of Plantronics Corporation Page 25 Ordering Codes (continued) PEC Comcode App Stand (large, black) n/a 846320851 Stand (large, white) n/a 846320844 STANDLARGE WH Stand (small, black) nla 846320810 STANDSMALL BL Stand (small, white) n/a 846320802 STANDSMALL WH User tray (black) n/a 846320240 USER TRAY DWR B User tray (white) n/a 846320232 USER TRAY DWR W Component Desk Stands and User Trays STANDLARGE BL Designation (Button Assignment) Cards and Covers Designation card* — MLX-10, MLX10D n/a 106448707 KITD182459 PRT Designation card* — MLX-20L n/a 106448723 KITD182461 PRT Designation card* — MIX28D n/a 106448715 KITD182460 PRT Designation card set †— DSS n/a 106448756 KIT Set DSS Designation card covers†— DSS (black) n/a Designation card covers †— DSS (white) n/a . * Twelve per package † Includes both top and bottom cards or covers Page 26 106448731 KITD182462 PRT 106448749 KITD182463 PRT Ordering Codes (continued) Component PEC Comcode App Designation (Button Assignment) Cards and Covers, continued Designation card set* — QCC n/a 106561673 KITD182562 PRT † Designation card covers — MLX-10, MLX10D, MLX20L n/a 106448681 KITD182457 PRT Designation card covers†— MLX-28D n/a 106448699 KITD182458 PRT Analog Multiline Telephones—Miscellaneous Add-Ons Desk Stands and Wall Mounts Adjustable desk stand, 10-button 32002 103746855 11A Adjustable desk stand, 34-button 32003 103746863 11C Fixed desk stand, 5-& 10-button 32004 103746848 10A Desk stand/wall mount 14A, BIS-10 n/a 103804290 14A-003 Desk stand/wall mount 14B, BIS-22 n/a 103964458 14B-003 Desk stand/wall mount 14C, BIS-34 n/a 103979837 14C-003 Fixed desk stand and wall mount, 5-button Kit of parts 32000 103804290 10A 32000 103995882 D-1 81230 Wall mount, 10-button Kit of parts 32001 32000 103747846 103995882 201A D-1 81230 Wall mount, 34-button Kit of parts 32006 32000 103747853 103995882 203A D-181230 Faceplates BIS-10 n/a 105203186 BIS-22 n/a 105336986 KIT PRTSD-181582 KIT PRTSD-181784 * Eight cards per kit (four sets) † Four per package Page 27 Ordering Codes (continued) Component PEC Comcode App Faceplates, continued BIS-22D BIS-34 and BIS-34D n/a n/a 105690762 105203194 D-1 82210 D-181583 10-button BIS n/a 105336978 D-181785 22-button BIS n/a 105336960 D-181784 22-button BIS with display n/a 105690770 D-182211 34-button BIS n/a 105336956 D-181783 Display console (FM1) (includes one faceplate) n/a 105299754 D-181727 Display console (FM2 & R3) (includes one faceplate) n/a 105486252 D-182041 Button Label Sheets Single-Line Telephones—Miscellaneous Add-Ons Ground-Start Button 31021 405792839 Key-KS 23566L1 110AB1-100JP12 110A1 trough D-Rings D8W cords Parts list n/a n/a 104409396 104407960 n/a n/a n/a 842139248 103786802 n/a SYSTIMAX™ MERLIN® Wiring Kit 110A1 trough (5) 110AB1-100JP12 modular block (2) 110AB1 110 punch down block (1) D-Rings (6) 110P8A5B patch cords (12—4-pair—5-ft. patch cords) D8W cords (24—14 ft.) Template Instruction sheet Parts List 3103-MER 106393671 n/a n/a n/a 104407960 104409960 103823845 842139248 KS23566L1 Miscellaneous Parts Interconnect Wiring Kit Page 28 n/a n/a 846619989 n/a 103786802 n/a n/a 846613933 846613941 n/a 846623924 NOTES Page 29 Control Unit Modules Module Line/Trunk Type Station Type Processor N/A N/A Power supply N/A N/A 008 N/A Analog multiline telephone; Call Management System; analog data via a modem 008 MLX N/A MLX telephone; digital data device (such as the ISDN 7500B Data Module) Page 30 Specifications Memory Sizes: large and small Highlights: 68000 processor at 10 MHz, built-in modem; built-in diagnostics; Key, Behind Switch, or Hybrid/PBX mode option; RAM backup for 12 days Ports: top RS-232C port for SMDR; bottom RS-232C port for system programming PC Power input: 117 VAC Power output: +5 VDC (10 A), -5 VDC (2.50 A), -48 VDC (2.05A) Capacity: 54 unit loads Capacity: 8 analog stations Signaling: analog multiline telephone protocol (40 kbps) Loop range: 1000 feet in-building or in-range out-of-building (with analog IROB protectors) service only Capacity: 8 digital stations, each with 1 or 2 endpoints (each endpoint is assigned an individual extension number), including the following station types: ■ digital voice only ■ digital voice with Voice Announce to Busy ■ digital voice and digital data (via ISDN 7500B Data Module) ■ digital voice and MFM ■ digital data only (ISDN 7500B Data Module) Signaling: ISDN-BRI S/T protocol (two 64-kbps B channels, one 16-kbps D channel) on a passive bus Power: 48-VDC phantom power to telephone; 48 VDC over a separate pair (7-8) to an operator DSS console Loop range: 1000 feet, in-building and in-range out-ofbuilding (with MLX lROB protectors) service only Page 31 Control Unit Modules (continued) Module Line/Trunk Type 008 OPT N/A On-premises or offpremises single-line telephone 012 (T/R) N/A Single-line telephone; MERLIN Attendant; MERLIN MAIL Voice Messaging System; T/R adjunct (such as an answering or fax machine); analog data device (such as a modem) Page 32 Station Type Specifications Capacity: 8 T/R stations* on 2-way voice transmission path with support for telephones with message-waiting LEDs; 2 TTRs Notice to Telco: Meets FCC Class C Ringing current: 105-Vrms, 30-Hz sinusoidal ringing superimposed on -48 VDC; a ring generator must be installed in the power supply module of each carrier that has a 008 OPT module. REN: < 1.0 per port Disconnect signal: 900 ms (T/R short for answering machines, G3 fax, etc.) Switchhook flash detection: 300-1200 ms Loop resistance: Serves 2-wire loops to 1300 ohms, including stations Capacity: 12 T/R stations on 2-way voice transmission path with support for telephones with message-waiting LEDs, 2 TTRs Power: 21-VDC, 600-ohm battery source Ringing current: 105-Vrms, 30-Hz sinusoidal ringing superimposed on -48 VDC; a ring generator must be installed in the power supply module of each carrier that has a 012 module. REN: < 1.0 per port Disconnect signal: 900 ms (T/R short for answering machines, G3 fax, etc.) Switchhook flash detection: 300-1200 ms * The system recognizes the OPT module as an 012 module having 12 ports. However, the OPT module has only 8 jacks. Therefore, each installed OPT module decreases the system’s capacity by 4 ports. Page 33 Control Unit Modules (continued) Line/Trunk Type Station Type 100D T1 or PRI N/A 400 † Loop-start and TTR Power failure transfer (PFT) telephone 400EM Tie trunk N/A 400 GS/LS/TTR Loop-start or groundstart and TTR PFT telephone; button needed for ground-start PFT telephone Loop-start Analog multiline telephone; Call Management System; PFT telephone Loop-start or groundstart Analog multiline telephone; Call Management System; PFT telephone Module † 408 408 GS/LS † Although these MERLIN II modules are supported in the MERLIN LEGEND Communications System, the 400 GS/LS and the 408 GS/LS are the recommended modules. Page 34 Specifications Capacity: 24 Iines/trunks for voice and analog data or 23 lines/trunks for voice and data with 1 channel used for signaling Mode: multiplexes 24 or 23 Iines/trunks into 1 facility and demultiplexes 1 facility into 23 or 24 lines/trunks Speed: Up to 64 kbps Signaling: DS1 over 4-wire; T1 uses robbed-bit or commonchannel; PRI has ISDN-PRI (23 B + D) Capacity: 4 lines/trunks, 4TlTRs, 1 PFT telephone Signaling: Loop-start Capacity: 4 tie lines Method of completion: automatic start, immediate-start, wink-start, or delay-dial-start Signaling: E&M type 1S, type 1C, type 5 Capacity: 4 lines/trunks, 4 TTRs, 1 PFT telephone Signaling: Loop-start or ground-start, optioned per port Capacity: 4 Iines/trunks, 8 stations, 1 PFT telephone Station signaling: analog multiline telephone (40 kbps) Line/trunk signaling: Loop-start line/trunk; analog voice Loop range: 1000 feet, in-building and in-range out-of building (with analog IROB protectors) service only Capacity: 4 Iines/trunks, 8 stations, 1 PFT telephone Station signaling: analog multiline telephone (40 kbps) Line/trunk signaling: loop-start or ground-start Iine/trunk (optional per port); voice Loop range: 1000 feet, in-building and in-range out-ofbuilding (with analog IROB protectors) service only Page 35 Control Unit Modules (continued) Module Line/Trunk Type Station Type 800 ‡ Loop-start PFT telephone 800 DID Direct Inward Dialing N/A Loop-start or groundstart PFT telephone; button needed for Ground-start PFT . 800 GS/LS ‡ Although this MERLIN II module is supported in the MERLIN LEGEND Communications System, the 800 GS/LS is the recommended module. Page 36 Specifications Capacity: 8 lines/trunks, 2 PFT telephones Signaling: loop-start Capacity: 8 trunks, 2 TTRs Transmission: incoming calls only; 2-way (1-pair) fixed impedance to DID trunks; no outgoing calls Signaling: loop-reverse battery; wink-start or immediatestart; accepts touch-tone dialing Capacity: 8 lines/trunks, 2 PFT telephones Signaling: Loop-start or ground-start Page 37 Adjunct Summary Equipment Type Specifications Alerts (AC)* ■ ■ Alerts (DC) ■ ■ Answer/ Record Machine* ■ ■ ■ Any audible or visual alert that operates on 20-30-Hz ringing signals Associated with a specific station (supplemental alert) or works on a programmed line/trunk port (external alert) External Ringer—Loud External Ringer Any audible or visual alert that operates on 48-VDC ringing signals Associated with a specific station (supplemental alert) or works on a programmed line/trunk port (external alert) Alert bell Alert horn Alert strobe Alert chime Alert deluxe horn Alert switch Industry-standard machine Low ringer equivalence (less than 0.15 or < 1.0 total REN for T/R port) Ability to recognize 600-ms disconnect signal or other means of automatic disconnect (such as voice reset disconnect timer, fixed recording time) Model 1330 answering machine Model 1531 Remote Answering System telephone * Cannot be connected to a QCC. Page 38 AT&T Products Interface * LS or GS/LS T/R MFM GPA SAA Line Jacks 012 Station Jack Digital Station Jack Analog Station Jack Analog Station Jack Requires Universal Paging Access Module (UPAM) to provide 48 VDC. Page 39 Adjunct Summary (continued) Equipment Type Cordless Telephone* Specifications ■ ■ AT&T Products Must have touch-tone dialing capability when connected via MFM; rotary or touch-tone dialing can be used on T/R port. Single line 5320 Cordless Telephone 5200 Cordless Telephone 5500 Cordless Telephone Credit Card Verification Terminal* ■ Must have touch-tone dialing capability when connected via MFM; rotary or touch-tone dialing can be used on T/R port. N/A Dial Dictation* ■ A device that requires contact closure can be used on LS/GS line jack only with UPAM N/A Direct Station Selector ■ A maximum of 2 DSSs can be connected to an operator console. A 329A power unit must be added to an operator console having 2 DSSs. Connects to “DSS” jack on operator console N/A ■ ■ * Cannot be connected to a QCC. Page 40 Interface LS or GS/LS T/R MFM GPA SAA Line Jacks 012 Station Jack Digital Station Jack Analog Station Jack Analog Station Jack Page 41 Adjunct Summary (continued) Equipment Type Specifications Fax* ■ ■ Group Calling Delay Announcement* ■ ■ ■ ■ Hands Free Unit ■ ■ Headset for analog multiline telephone Must have touch-tone dialing capability when connected via MFM; rotary or touch tone dialing can be used on T/R port. Industry-standard analog interface AT&T 3410D AT&T 3500D AT&T 3510D AT&T 3520D AT&T 3530D AT&T Fax 4515D AT&T Fax 4525D AT&T Fax 9015 AT&T Fax 9020 AT&T Fax 9022 AT&T Fax 9025FX AT&T Fax 9035FX Industry-standard announcement device Must provide automatic disconnect Each calling group can have its own announcement (maximum 32). A device can provide delay announcement for more than one group. Model 1330 Answering Machine For use with analog multiline telephones Connects directly to telephone 5202A N/A * Cannot be connected to a QCC. Page 42 AT&T Products DA-5 Digital Voice Announcer Supra StarSet II StarMate E Interface LS or GS/LS T/R MFM GPA Line Jacks 012 Station Jack Digital Station Jack Analog Station Jack Analog Station Jack Page 43 Adjunct Summary (continued) Equipment Type Specifications AT&T Products Headset for MLX telephone N/A StarSet II— StarMate-E Supra—StarMate-E Headset Adapter ■ ■ Loudspeaker Paging ■ ■ Message Waiting Indicator ■ Modem ■ ■ ■ Page 44 Need to program Auto Answer All button for use with 502B, 502C Connects directly to telephone OTHER jack 502A 502B 502C External paging system using DTMF signaling is connected to LS or GS line jack. CPE paging systems require an interface unit; if CPE has 2wire input, the BOGEN UPAM-K (58500) can be used. PagePac 20 PagePac 20 with ZoneMate 9 PagePac 20 with ZoneMate 39 PagePac 6 PagePac 6 Plus For single-line sets Connects directly to telephone Z34A (PEC 31032) If the modem supports touch-tone dialing via the associated data terminal, the keyboard can be used for dialing. If the modem does not support touch-tone dialing, an associated basic (single-line) telephone can be used for dialing. Modem Model 4000 Modem Model 2224G Modem Model 4024 Modem Model 2296A Modern Model 2296 Interface LS or GS/LS T/R MFM GPA SAA Line Jacks 012 Station Jack Digital Station Jack Analog Station Jack Analog Station Jack * For modem model 2224G only. Page 45 Adjunct Summary (continued) Equipment Type Specifications Music-onHold* ■ Any FCC-registered 8-ohm music source or recorded announcement device Speakerphone ■ Connect directly to telephone For single-line sets only ■ SMDR Printer ■ ■ Connects to upper RS-232 jack on processor module Must be located within 50 feet of CU or use ADU to extend distance AT&T Products Magic on Hold® 4A† (PEC 3120-02W) 203A (PEC 3131-008) AT&T 475 AT&T 476 AT&T 572 * If you use equipment that rebroadcasts music or other copyrighted materials, you may be required to obtain a copyright license from and pay license fees to a third party such as the American Society of Composers, Artists, and Producers (ASCAP) or Broadcast Music Incorporated (BMI). Or you can purchase a Magic on Hold system, which does not require you to obtain such a license, from AT&T or an authorized dealer. † Requires 2500SM telephone. Page 46 Interface LS or GS/LS T/R MFM GPA SAA Line Jacks 012 Station Jack Digital Station Jack Analog Station Jack Analog Station Jack * Music Coupler required (PEC 61398). Page 47 Uninterruptible Power Source (UPS) Backup Times UPS Units Backup Time Limit PEC Basic 500VA 15 min 2403-050 1 500VA Reserve Cabinet 1 hr 24035 * Backup times for normal system operation at maximum system load Page 48 Power Supply Unit Load Requirements Unit Load Calculation Rules Installed Modules Calculation Hybrid/ PBX and Modified Key/ Behind Switch 6* Not required Square Key/ and Behind Switch 4 or fewer † Not required Mode * The 391A1 power supply unit generally supports 6 modules of any type in Hybrid/PBX mode. However, if all 6 carrier slots have the following conditions, the unit load (UL) total may exceed 54 and auxiliary power may be required. ■ Only MLX or analog multiline station modules are installed. ■ More than 45 MLX-20L or 34-button analog multiline stations are installed. † The 391A1 power supply unit generally supports 4 modules of any type in Square Key mode. Page 49 Power Supply Unit Load Requirements (continued) Unit Load Calculation Rules (continued) Mode Square Key/ Behind Switch Installed Modules 5 or more Calculation ■ ■ ■ Use the “Unit Load Rating of System Modules” table and instructions below to determine the estimated ULs: ■ If ULs equal 54 or less, an Auxiliary Power Unit 9024 is not required. ■ If ULs exceed 54, use “Unit Load Rating of System Modules” table to determine the actual ULs for the system. If the actual ULs exceed 54, try to exchange modules between carriers to reduce the ULs below 54.* If the modules cannot be exchanged to reduce the ULs below 54, an Auxiliary Power Unit 9024 is required. * Empty slots are not permitted between modules. Page 50 Power Supply Unit Load Requirements (continued) Unit Load Rating of System Modules Module Unit Load Module Unit Load 008 (analog multiline telephones) 12.0 400EM 008 MLX 13.5 408 GS/LS 12.0 008 OPT 8.0 408 (LS) 12.0 012 T/R 8.4 800 GS/LS 0.0 100D (DS1) 0.0 800 (LS)* 0.0 400 GS/LS/TTR 0.0 800 DID 8.0 400 (LS)* 0.0 Processor 0.0 8.0 * This is a MERLIN II loop-start-only module that can be reused in the MERLIN LEGEND Communications System. Page 51 Power Supply Unit Load Requirements (continued) Unit Load Rating of System Lines, Telephones, and Adjuncts Unit Load Network Access Lines* DID DS1 GS/LS Tie 1.0 0.0 0.0 1.4 Telephones MLX-10 and MLX-10D MLX-28D MLX-20L BIS-10 BIS-22 and BIS-22D BIS-34 and BIS-34D MLC-5 5-Button 10-Button Basic 10-Button HFAI 34-Button Basic 34-Button DLX 34-Button BIS 34-Button BIS/DIS Single-line telephone 1.2 1.7 1.6 1.1 1.3 1.5 0.0 0.8 1.1 1.2 1.1 1.7 1.4 1.4 0.7 Optional Equipment DSS console† MFM ‡ General purpose Adapter Hands Free Unit Headset adapter 0.9 1.3 1.0 1.0 1.0 * Unit loads are computed per trunk for trunk-type network access lines. † Up to two DSS consoles (one DSS per MLX-28D or MLX-20L) can be powered from each control unit carrier. For example, a 3-carrier system can have 6 system operator positions, each with one DSS powered from the control unit. ‡ The MFM is powered by an individual wall power unit located at the station. Page 52 System Features Feature Mode Key Behind Switch Automatic Maintenance Busy Automatic Route Selection Callback Calling Restrictions Coverage Delayed Ring interval Direct Inward Dialing Direct-Line Console options Directory Extension Status Forced Account Code Entry Group Calling Headset Status Hold disconnect Inside dial tone Labeling Loudspeaker Page Microphone Disable Night Service Page 53 System Features (continued) Feature Mode Key Paging groups Park Pickup Group Pools (trunk groups) Queued Call Console Options Recall interval Reminder Cancel Remote Access Remote call forward Station Message Detail Recording System Numbering System Restart System Speed Dial Toll Type Touch-Tone or rotary signaling Transfer Options Voice Announce to Busy Page 54 PBX Behind Switch NOTES Page 55 K Key mode P Hybrid/PBX mode B Behind Switch mode Telephone and Operator Console* Features Program Code Feature Code Account Code Entry ❋ 82 82+ code Alarm† ❋ 759 Auto Answer All ❋ 754 Auto Answer Intercom ❋ 753 Auto Dial Inside (ext., group, DGC, zone) Outside ❋ 22+ Feature Automatic Line Selection Enter Exit Barge-ln † Callback Automatic On off Selective Cancel ext. no. ❋ 21+ tel. no. ❋ 14 ❋ ❋ 14 ❋ 58 ❋ 12 ❋ ❋ 12 ❋ 55 * A QCC can be used in Hybrid/PBX mode only. † This is an operator console feature. Page 56 55 ❋ 55 MLX10D MLX28D MLX20L Single Line MLX10 Analog Multiline* KPB KPB KPB KP KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KP * Includes the MLC-5 telephone. Page 57 Telephone and Operator Console Features (continued) Feature Call Waiting On off Pickup Program Code Feature Code ❋ 11 ❋ ❋ 11 87 Camp-On ❋ 57 57 Conference ❋ 772 772 Coverage Receiver buttons: Group Primary Secondary Sender buttons: Cover inside & outside calls Cover outside calls only Coverage Off 42+ ext. no. ❋ 40+ ext. no. ❋ 41+ ext. no. ❋ ❋ 48 ❋ ❋ 48 ❋ 49 Do Not Disturb ❋ 47 Drop ❋ 773 Page 58 773 MLX10D MLX28D MLX20L Single Line MLX10 Analog Multiline* KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB B B B B B KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB B B B B B KPB * Includes the MLC-5 telephone. Page 59 Telephone and Operator Console Features (continued) Feature Extension Status Hotel/Motel mode Console buttons* ES Off ES1 ES2 Telephone buttons ES Off ES1 ES2 Calling group/CMS mode Calling Group Supervisor buttons* Unavailable Available Agent buttons Sign-in (available) Sign-out (unavailable) After-call work state (CMS only) Feature button Program Code Feature Code ❋ 760 ❋ 761 ❋ 762 760 + DSS 761 + DSS 762 + DSS ❋ 44 ❋ 45 ❋ 44 45 44 ❋ 760 ❋ 762 760 + DSS 762 + DSS ❋ 44 44 ❋ 44 ❋ 45 ❋ 20 34+ ext. no. Follow Me Forward Inside Outside Forward/Follow Me Cancel Cancel all Cancel one Cancel from your telephone * This is an operator console feature. Page 60 ❋ 33 33+ ext. no. 33+ line no. 34 ❋ ❋ 34+ ext. no. 33+ ext. no. ❋ MLX10D KPB KPB MLX28D MLX20L KPB KPB KPB KPB KPB KPB KPB KPB Single Line MLX10 Analog Multiline* KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB * Includes the MLC-5 telephone. Page 61 Telephone and Operator Console Features (continued) Feature Group Calling Auto Dial button Program Code Feature Code ❋ 22+ calling group ext. no. Group Page Auto Dial button ❋ 22+ group ext. no. Headset Auto Answer Mute (Headset/Handset) Status Off ❋ 780 ❋ 783 ❋ 782 ❋ 781 Hold Hold Release Last Number Dial 771 ❋❋ ❋ 84 Messaging Message—Cancel 84 ❋ 53+ .ext. no. Message—Delete Message Leave button Message —Next Message —Scroll Posted Message Return Call ❋ 26 26 25 28 29 25 ❋ 28 ❋ 29 ❋ 751 ❋ 27 27 Message Light Off ❋ 54 54 Night Service* ❋ 39 39 * This is an operator console feature. Page 62 ❋ MLX10 Analog Multiline* KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB B B B B B B B B B B B KPB KPB KPB KP KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB MLX10D MLX28D MLX20L KPB KPB KPB Single Line KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB * Includes the MLC-5 telephone. Page 63 Telephone and Operator Console Features (continued) Program Code Notify Send Receive Park Park Zone Auto Dial* Feature Code ❋ 757+ ext. no. ❋ 758+ ext. no. ❋ 86 ❋ 22+ Park zone ext. no. Personal Speed Dial ❋ 21 Personalized Ring ❋ 32+ 01-24 ring no. (l-8) Pickup General use Specific extension Specific line Group 9 ❋ 9+ ext. no. ❋ 9+ line no. ❋ 88 ❋ 9 + ext. no. 9 + line no. 88 Privacy On Off ❋ 31 31 ❋ 31 Recall ❋ 775 775 * This is an operator console feature. Page 64 MLX10D MLX28D MLX20L KPB KPB KPB KPB KPB KPB KPB KPB Single Line KP Analog Multiline* KPB KPB KPB KPB KPB KP KPB MLX10 KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KP KPB KPB KPB KPB KPB KP KPB KPB KPB KPB KPB KPB KPB * Includes the MLC-5 telephone. Page 65 Telephone and Operator Console Features (continued) Feature Reminder Set Cancel Missed Operator Set Program Code Feature Code ❋ 81 81 + time + A or P ❋ 81 ❋❋ 81 ❋ 752 81 + ext. no. + time + A or P ❋ 81 + ext. no. Operator Cancel Ringing & Idle Line Preference Cancel ❋ 343 ❋ 344 Ringing Options Individual lines Immediate Ring Delayed Ring No Ring All lines Immediate Ring Delayed Ring No Ring Abbreviated Ring Off On Send ring On Cancel ❋ 347 ❋ 346 ❋ 345 Saved Number Dial ❋ 85 Send/Remove Message* ❋ 38 Signaling (manual) ❋ 37 ❋ 36 ❋ 35 ❋ 342 ❋ 341 ❋ 15 ❋ ❋ 15 ❋ 23 + ext. no. * This is an operator console feature. Page 66 38 + DSS MLX10D MLX28D MLX20L Single Line MLX10 Analog Multiline* KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB P P P P P P KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB KPB * Includes the MLC-5 telephone. Page 67 Telephone and Operator Console Features (continued) Program Code Feature Code ❋ 24 + code 600-729 Transfer ❋ 774 774 Voice Announce On Off ❋ 10 Feature System Speed Dial Page 68 ❋❋ 10 MLX10D MLX28D MLX20L Single Line MLX10 Analog Multiline* KPB KPB KPB KP KPB KPB B B B B B KPB KPB KPB KPB KPB * Includes the MLC-5 telephone. Page 69 Reference Documents Document Number Document Title System Reference 555-610-110 555-610-141 System Reference Pocket Reference System Setup and Modification 555-610-111 555-610-112 555-610-113 555-610-116 555-610-117 System Programming Key System Planning PBX System Planning Key System Planning Forms only PBX System Planning Forms only Data Guide 555-610-114 555-610-118 Data Guide Data Planning Forms only Telephone User Support 555-610-120 555-610-122 555-610-123 555-610-124 555-610-125 555-610-121 Analog Multiline Telephones User's Guide MLX-10D,™ MLX-28D,™ and MLX-20L™ Digita/ISDN Display Telephones User’s Guide MLX-10™ Digital/lSDN Non-Display Telephone User’s Guide MLX-10™ and MLX-10D™ User Cards MLX-28D™ and MLX-20L™ User Cards Single-Line Telephones User’s Guide Operator Guides 555-610-131 555-610-132 555-610-133 Analog Direct-Line Consoles Operator’s Guide Digital/ISDN Direct-Line Consoles Operator's Guide Digital/ISDN Queued Call Console Operator’s Guide Miscellaneous 555-610-130 555-610-140 Page 70 Calling Group Supervisor’s Guide Installation, Programming, and Maintenance