Download ETS 300 001 - Second Edition - Attachments to the Public

Transcript
Page 64
ETS 300 001 - Chapter 4 : December 1994
Table A.4.4.1: Maximum transmission levels.
COUNTRY
Vf
(V)
Austria
Belgium
Cyprus
Denmark
Finland
France
Germany
Greece
Iceland
Ireland
Italy
Luxembourg
Malta
Netherlands
Norway
Portugal
Spain
Sweden
Switzerland
U. Kingdom
60
48
48
TEST VALUES
Rf
(Ω)
If
(mA)
19, 60
400, 1 600
800
16, Imax
46, 54
60
60
48
yes
not mandatory
1 400 resp. 300
1 000, 2 530
20, 35, 55
14, Imax
100
44, 48, 52
60
1 880, 1 100, 720
48
60
55
48
1 130
460
300
500, 1 100, 1 700
43, 48, 57
50
2 200, 1 200, 600
400 min.
14, 60
yes
not applicable
yes
yes
25 - 100
Figure A.4.4.1: Maximum transmission levels Feeding bridge as specified in Chapter 1
A.4.4.1 (DK) 1
Remarks
The principle of test is shown in figure A.4.4.1 (DK) 1.
Figure A.4.4.1 (DK) 1
yes