Download GW6600 User Manual
Transcript
18: Automatic operator selection _______________________________________________________________________________________________________ In the Exclusive Group field type in 3g. From the dropdown menu, select the Choose Minimum ifup Interval option. From dropdown menu, select the Interface Start Timeout option. From dropdown menu, select the Signal Threshold option. All available WAN interface options are described in the table below. Name Type Required Default Description Health Monitor Interval Dropdown menu Yes 10 sec Interval used to monitor Signal strength Health Monitor ICMP Host(s) Dropdown menu No none Target IP address for ICMCP packets Health Monitor ICMP Timeout Dropdown menu Yes 3 sec ICMP timeout Attempts Before WAN Failover Dropdown menu Yes 3 Number of fail attempts of Health Monitor before interface is torn down Attempts Before WAN Recovery N/A N/A N/A N/A Priority Number Yes 0 Higher value is higher priority Minimum ifup Interval Dropdown menu Yes 300 sec Minimum interval between two successive interface start attempts Interface Start Timeout Dropdown menu Yes 40 sec Time for interface to startup Signal Threshold (dBm) Dropdown menu Yes -115 if signal is lower than this then is marked as fail 18.3.1.3 Setting options for automatically created interfaces From the top menu on the web interface page, select Services ->Mobile Manager. The Mobile Manager page appears. _______________________________________________________________________________________________________ © Virtual Access 2015 GW6600 User Manual Issue: 2.3 Page 115 of 305