Download PowerFlex 700S Drives - Phase II Control (Frame
Transcript
PowerFlex® 700S Drives - Phase II Control (Frame Sizes 9-13) 55 I/O Wiring Examples This section provides basic information to wire the PowerFlex 700S Drive. Table Q TB2 Terminals — Digital Wiring Examples Input/Output Digital Inputs used for enable and precharge control. Note: 24V DC Supply supports only on-board digital inputs. Do not use for circuits outside the drive. Connection Example Sourcing Digital Inputs - Internal Power Supply 1 2 Com 24V dc 3 4 9 5 10 6 2 12 4 6 7 8 Sinking Digital Inputs - Internal Power Supply Com 24V dc 3 4 9 5 10 6 11 7 12 8 13 14 15 16 Sinking Digital Output - Internal Power Supply 1 2 3 4 5 6 7 8 • • 5 2 • 24V dc 3 1 • 11 7 8 Note: 13 The factory default for 14 Digital Inputs is 24V. This 15 must be switched in 16 order to use 115V. Refer to "Switch Settings" on page 51 for switch Sourcing Digital Outputs - Internal Power Supply Com settings. 1 Note: Digital Inputs 1-3 are 12 - 24V DC. Sourcing and Sinking Definitions The digital inputs and digital outputs of the PowerFlex 700S AC drive support Sourcing or Sinking configuration. Typically, digital inputs are sourcing devices and digital outputs are sinking devices. The following definitions apply throughout this section: Com 24V dc Sourcing a Digital Input - The digital input common (return) is connected to the power supply common. Applying a positive voltage to the digital input will cause it to activate (pull up). Sinking a Digital Input - The digital input common (return) is connected to the power supply positive voltage. Applying 0V or common to the digital input will cause it to activate (pull down). Sourcing a Digital Output - The digital output common (return) is connected to the power supply common. The device to be controlled by the digital output is connect to the positive voltage and the device common is connected to the digital output. Sinking a Digital Output - The digital output common (return) is connected to the power supply positive voltage. The digital output is connect to the device to be controlled and the device common is connected to the power supply common. Note: Digital Inputs 1-3 can only be configured as sourcing inputs. Digital Inputs 4-6 can be configured as sourcing or sinking inputs.