Download Functional Description Manual
Transcript
SYNAX The Terminal 1-9 The list used in the example has only six programmable elements after this step. If the programmed length of the lis is equal to the maximum length, then the key <STRG/E> has no effect: 21.0 22.0 Input 22.0 23.0 <STRG/L> 23.0 24.0 24.0 25.0 25.0 26.0 1.3 21.0 CLC transmits! 26.0 The structure of the parameter files Files are produced when storing CLC parameters. The following describes their structure. A parameter file is made up of one or several management sections and the data blocks (usable data). Only ASCII symbols from IBM (MS-DOS) are used in the parameter file. Every line is concluded with <CRLF>. Parameters file management A management section of a parameter file is made up of five lines. Every line must be concluded with <CRLF>. The first line must include "SERCOS-ASCII". The fifth line includes the drive address set on the hardware of the drive. The drive address is made up of two symbols and must be located within the range 01 to 99. Lines 2, 3 and 4 (free lines) are available for use by the user. They may have no more than a maximum of 60 symbols. If data from the CLC controller card is stored, then the CLC will enter the symbol <*> 12 times in the lines 3 and 4. In the line 2 the CLC writes the firmware version. When using the free lines, the user can later program these as needed. Structure of the management section SERCOS-ASCII <free line> <free line> <free line> <drive address> The CLC creates the following management section when storing the parameter files: DOK-SYNAX*-SY*-06VRS**-FK01-EN-P