Download latest version
Transcript
Simulator Reference Manual Global Settings Name Type Default Description NoStopOnUnknownParam String WARN Specifies action to be taken in the event of an unknown parameter being encountered in a .MODEL statement. Choices are: TRUE: No action taken, simulation continues normally FALSE: An error will be raised and the simulation will abort WARN: A warning will be displayed but the simulation will continue This will be overridden by a .OPTIONS setting of the same name. See page 235 MaxVectorBufferSize Numeric 32768 See “Data Buffering” below TotalVectorBufferSize Numeric Available RAM/10 See “Data Buffering” below TempDataDir String %STARTDIR% Location of temporary binary data file if data_file is not specified on command line LibraryDiagnostics String Full Controls output of messages relating to model library search. Specify None to disable Data Buffering The simulator buffers data before writing it to disk. By doing so the binary data file can be organised more efficiently allowing data to be recovered from it quickly. There is a relationship between buffer size and read in time as illustrated by the following table. This shows the time taken to read in a 14MByte vector from a 1GByte data file with the system disk cache cleared. The tests were performed with three different buffer sizes on two different systems. One system was an old notebook computer with an IDE disk system. The other was a machine with a high performance SCSI Ultra 320 disk. 18