Download MA6440 - Kollmorgen
Transcript
P (Store Parameters) P Immediate Purpose Stores parameters to non-volatile memory. Values are restored to working memory upon power-up and by issuing the A0 command. Syntax P Arguments none Programming guidelines Type P <Enter>. All parameters and fast memory locations 128-191 will be saved to non-volatile memory in addition to the following parameters: Initial Velocity (F) Final Velocity (V) Ramp slope (M) Jog Speed (^) Trip Point (O) Resolution Mode Limit Switch Polarity RS-485 Node Address User Programs The default mode after memory initialization is Variable Resolution Mode at Full Speed. Note: Whenever a change in any of these parameters or code in Fast RAM locations 128-191 is to be saved during power cycling, the P command must be executed. 6440 User Manual - Rev 2 MA6440 7 - 21