Download Digital Projection E-Vision 8000 User Guide
Transcript
Digital Projection E-Vision THE OPERATION COMMANDS 8000 Series Remote Communications Guide Notes ...continued from previous page <operation> <command> <values> Notes h.keystone =?+- -350 ~ +350 The sum of the absolute values of h.keystone and v.keystone cannot be greater than 350. v.keystone =?+- -200 ~ +200 The sum of the absolute values of h.keystone and v.keystone cannot be greater than 350. warp.rotat =?+- -20 ~ +20 Each unit is ¼°. warp.pinbrl =?+- -100 ~ +100 Pincushion/Barrel warp.tlc.x warp.tlc.y =?+- x: -192 ~ +192 y: -120 ~ +120 Top Left Corner warp.trc.x warp.trc.y =?+- x: -192 ~ +192 y: -120 ~ +120 Top Right Corner warp.blc.x warp.blc.y =?+- x: -192 ~ +192 y: -120 ~ +120 Bottom Left Corner warp.brc.x warp.brc.y =?+- x: -192 ~ +192 y: -120 ~ +120 Bottom Right Corner warp.reset (execute) blank.top =?+- 0 ~ 360 blank.btm =?+- 0 ~ 360 blank.left =?+- 0 ~ 534 blank.right =?+- 0 ~ 534 blank.rst (execute) eb.stat =? 0 = Off 1 = On Edge Blend eb.wht.top =?+- 0, 200 ~ 500 Blend Width Top 1-199 not allowed eb.wht.btm =?+- 0, 200 ~ 500 Blend Width Bottom 1-199 not allowed eb.wht.left =?+- 0, 200 ~ 800 Blend Width Left 1-199 not allowed eb.wht.right =?+- 0, 200 ~ 800 Blend Width Right 1-199 not allowed eb.blk.top =?+- 0, 8, 16, 24, 32 Black Level Uplift Area Top continued on next page... Rev F July 2014 61