SIEMENS CONTROL
n. Press
Menu Select hard key.
o. Press Program soft key.
p. Highlight the Shopmill folder and press the
contents of the Shopmill folder displays.
q. Highlight the GET_VALUES file.
r. Press the Select vertical soft key.
s. Press
INPUT hard key. The
Auto hard key.
t. Press
Cycle start hard key (green).
u. Write down, on paper, the information and data that displays near the
top part of the display screen (See Figure 16). This is the zero offset
and backlash data for the machine.
Figure 24 Record the axis data for zero offsets and backlash
when the data displays at the top of the screen.
v. Repeat steps t and u for all the available axes. No more data displays
when all the axes have been checked.
w. Press Manage programs vertical soft key.
x. Highlight the GET_VALUES file.
y. Press Delete... soft key. This deletes the GET VALUES file. This file is a
utilities program used specifically for getting the machine data for this
software update. Therefore, it should not be left in the system.
z. Press Yes soft key.
June 2002
MMC100 Software Update: MMC103 Update Procedure