Download Advanced Pressurized Water Reactor Simulator User Manual By
Transcript
WT = turbine control valve flow rate WD = steam dump valve flow rate WB = steam line break flow rate The specific volume and specific internal energy are given by : The main steam pressure is determined from the equation of state (i.e. steam table look-up) : The flow between the steam generators and the main steam system has the following form: Where PSG = steam generator pressure Ph = main steam pressure KV = main steam isolating valve loss coefficient KNZ = flow restrictor loss coefficients W = steam flow rate AV = total isolation valve flow area ANZ = flow restriction throat area h = steam density The steam flow rate determined by equation (5.11-6) should not exceed choke flow conditions. Steam flow rates through the turbine valves and steam dump valves and the steam line break flow, are all assumed to be choked flow. 5.12. Control and protection systems The control systems available in this simulator include those systems as described in Section 2.2 “PWR control loops”. In this section, brief model descriptions are provided for the following systems: (1) (2) (3) (4) Pressurizer pressure control system Pressurizer level control system Steam generator three element level control system Steam generator pressure control system 87