Controls, Indicators and Connections It provides a way to fire the input Pockels cell based on sync signals from two circuits: the pump laser Q-switch signal and the seed laser pulse train. SYNC ERROR indicator—when on and the SDG II is in synchronized mode, indicates the sync signal is absent or the seed laser is not modelocked. BWD (PD1, PD2 and RESET)—see “Bandwidth Detector” on page 4-6. MODE control—selects CONTINUOUS repetition rate firing (based on input trigger) or SINGLE SHOT firing (the corresponding LED turns on) MAN TRIG control—causes the three output triggers to fire a single pulse when the firing mode is set to SINGLE SHOT and the button is pressed. ENABLE controls (3)—turn the three adjustable output trigger signals on and off. If a signal is enabled, its corresponding LED is illuminated. When disabled, only that output is deactivated; the other outputs remain active. OUT 1 DELAY display, control and connector—the display shows the selected delay (0 to 1275 ns) between the pump laser Q-switch sync signal and the time the input Pockels cell is turned on to capture the current seed pulse in the Spitfire amplifier. The control knob adjusts the delay in 250 ps increments, or 10 ns increments if the knob is pushed in during adjustment. The corresponding BNC connector connects to the Spitfire’s HSD 1 TRIG BNC connector. This provides a low-voltage sync signal to the high-voltage driver, which turns on the input Pockels cell to capture the current seed pulse. OUT 2 DELAY display, control and connector—the display shows the selected delay (0 to 1275 ns) between the pump laser Q-switch sync signal and the time the output Pockels cell is turned on to eject the amplified pulse into the compressor. This delay must be greater than the setting for OUT 1 DELAY. The control knob adjusts the delay in 250 ps increments, or 10 ns increments if the knob is pushed in during adjustment. The corresponding BNC connector connects to the Spitfire’s HSD 2 TRIG BNC connector. This provides a low-voltage sync signal to the high-voltage driver, which turns on the output Pockels cell to eject the amplified pulse. SYNC OUT DELAY display, control and connector—the display shows the selected delay (0 to 1275 ns) between the time the output Pockels cell is fired and the time the user can send a trigger signal to a device (such as an oscilloscope) that is part of the target apparatus. The control knob adjusts the delay in 250 ps increments, or 10 ns increments if the knob is pushed in during adjustment. The corresponding BNC connector connects to the user’s oscilloscope for monitoring pulses, or to other apparatus of the target or data acquisition system. 4-5