Download ArmorStart Distributed Motor Controller with EtherNet/IP User Manual

Transcript
Chapter 7
Bulletin 280E/281E/284E Programmable Parameters
Table 28 - ArmorStart Parameters
Parameter
Number
Parameter Name
124
Drive Temp
125
Counter Status
126
Timer Status
129
Description
Factory Default
Group
Controller
Present operating temperature of the drive power section.
Read Only
Drive Display
284E
The current value of the counter when counter is enabled.
Read Only
Drive Display
284E
The current value of the timer when timer is enabled.
Read Only
Drive Display
284E
Torque Current
Displays the current value of the motor torque current as
measured by the drive.
Read Only
Drive Display
284E
131
Motor NP Volts
Set to the motor name plate rated volts.
Based on Drive Rating
Drive Setup
284E
132
Motor NP Hertz
Set to the motor nameplate rated frequency.
60 Hz
Drive Setup
284E
133
Motor OL Current
Set to the maximum allowable current.
Based on Drive Rating
Drive Setup
284E
134
Minimum Freq
Sets the lowest frequency that the drive will output
continuously.
0.0 Hz
Drive Setup
284E
135
Maximum Freq
Sets the highest frequency that the drive will output
continuously.
60 Hz
Drive Setup
284E
136
Start Source
Sets the control scheme that is used to start the Bulletin 284E
ArmorStart.
5 = Comm Port
(RS485 (DSI))
Drive Setup
284E
137
Stop Mode
Sets the Valid Stop Mode for the Bulletin 284E ArmorStart.
9=
Ramp + EM Brk
Drive Setup
284E
138
Speed Reference
Sets the Valid Speed References for the Bulletin 284E
ArmorStart.
5 = Comm Port
Drive Setup
284E
139
Accel Time 1
Sets the rate of acceleration for all speed increases.
10.0 Secs
Drive Setup
284E
140
Decel Time 1
Sets the rate of deceleration for all speed decreases.
10.0 Secs
Drive Setup
284E
141
Reset To Defaults
0 = Ready/Idle
Drive Setup
284E
143
Motor OL Ret
0 = Disabled
Drive Setup
284E
Used to reset drive to factory default settings
Enables/Disables the Motor Overload Retention function.
Table 29 - Bulletin 284E Advance Setup Parameter Descriptions
Parameter
Number
Parameter Name
151…154
Digital In 1 Sel
Digital In 2 Sel
Digital In 3 Sel
Digital In 4 Sel
Selects the function for the digital inputs.
155
Relay Out Sel
156
204
Description
Factory Default
Group
See Table 24.
Drive Advanced Setup
Sets the condition that changes the state of the output relay contacts.
0 = Ready/Fault
See Table 25.
Drive Advanced Setup
Relay Out Level
Sets the trip point for the digital output relay if the value of Parameter
155 (Relay Out Sel) is 6, 7, 8, 10, 16, 17, 18, or 20.
0.0
Drive Advanced Setup
169
Internal Freq
Provide the frequency command to drive when Parameter 138 (Speed
Reference) is set to “1” (Internal Freq).
60.0 Hz
Drive Advanced Setup
170…177
Preset Freq 0
Preset Freq 1
Preset Freq 2
Preset Freq 3
Preset Freq 4
Preset Freq 5
Preset Freq 6
Preset Freq 7
Provides a fixed frequency command value when Parameters 151…154
(Digital In x Sel) is set to Option 4 (Preset Frequencies).
See Table 26.
Drive Advanced Setup
178
Jog Frequency
Sets the output frequency when the jog command is issued.
10.0 Hz
Drive Advanced Setup
Rockwell Automation Publication 280E-UM001C-EN-P – September 2015