Chapter 7 Bulletin 280E/281E/284E Programmable Parameters Table 28 - ArmorStart Parameters Parameter Number Parameter Name 124 Drive Temp 125 Counter Status 126 Timer Status 129 Description Factory Default Group Controller Present operating temperature of the drive power section. Read Only Drive Display 284E The current value of the counter when counter is enabled. Read Only Drive Display 284E The current value of the timer when timer is enabled. Read Only Drive Display 284E Torque Current Displays the current value of the motor torque current as measured by the drive. Read Only Drive Display 284E 131 Motor NP Volts Set to the motor name plate rated volts. Based on Drive Rating Drive Setup 284E 132 Motor NP Hertz Set to the motor nameplate rated frequency. 60 Hz Drive Setup 284E 133 Motor OL Current Set to the maximum allowable current. Based on Drive Rating Drive Setup 284E 134 Minimum Freq Sets the lowest frequency that the drive will output continuously. 0.0 Hz Drive Setup 284E 135 Maximum Freq Sets the highest frequency that the drive will output continuously. 60 Hz Drive Setup 284E 136 Start Source Sets the control scheme that is used to start the Bulletin 284E ArmorStart. 5 = Comm Port (RS485 (DSI)) Drive Setup 284E 137 Stop Mode Sets the Valid Stop Mode for the Bulletin 284E ArmorStart. 9= Ramp + EM Brk Drive Setup 284E 138 Speed Reference Sets the Valid Speed References for the Bulletin 284E ArmorStart. 5 = Comm Port Drive Setup 284E 139 Accel Time 1 Sets the rate of acceleration for all speed increases. 10.0 Secs Drive Setup 284E 140 Decel Time 1 Sets the rate of deceleration for all speed decreases. 10.0 Secs Drive Setup 284E 141 Reset To Defaults 0 = Ready/Idle Drive Setup 284E 143 Motor OL Ret 0 = Disabled Drive Setup 284E Used to reset drive to factory default settings Enables/Disables the Motor Overload Retention function. Table 29 - Bulletin 284E Advance Setup Parameter Descriptions Parameter Number Parameter Name 151…154 Digital In 1 Sel Digital In 2 Sel Digital In 3 Sel Digital In 4 Sel Selects the function for the digital inputs. 155 Relay Out Sel 156 204 Description Factory Default Group See Table 24. Drive Advanced Setup Sets the condition that changes the state of the output relay contacts. 0 = Ready/Fault See Table 25. Drive Advanced Setup Relay Out Level Sets the trip point for the digital output relay if the value of Parameter 155 (Relay Out Sel) is 6, 7, 8, 10, 16, 17, 18, or 20. 0.0 Drive Advanced Setup 169 Internal Freq Provide the frequency command to drive when Parameter 138 (Speed Reference) is set to “1” (Internal Freq). 60.0 Hz Drive Advanced Setup 170…177 Preset Freq 0 Preset Freq 1 Preset Freq 2 Preset Freq 3 Preset Freq 4 Preset Freq 5 Preset Freq 6 Preset Freq 7 Provides a fixed frequency command value when Parameters 151…154 (Digital In x Sel) is set to Option 4 (Preset Frequencies). See Table 26. Drive Advanced Setup 178 Jog Frequency Sets the output frequency when the jog command is issued. 10.0 Hz Drive Advanced Setup Rockwell Automation Publication 280E-UM001C-EN-P – September 2015