Download C-DOT IVRS Installation Manual
Transcript
C-DOT IVRS INSTALLATION MANUAL Section No. 410-305-0760 System Practices Draft 03, May 2003 C-DOT IVRS INSTALLATION MANUAL © 2003, C-DOT Printed in India C-DOT IVRS INSTALLATION MANUAL DRAFT 03 MAY 2003 JYESTHA 2060 SERIES 300 : INSTALLATION CSP SECTION NO. 410-305-0760 THIS C–DOT SYSTEM PRACTICE REFERS TO THE C–DOT INTERACTIVE VOICE RESPONSE SYSTEM (ABBREVIATED AS C–DOT IVRS IN THE REST OF THIS PUBLICATION). THE INFORMATION IN THIS SYSTEM PRACTICE IS FOR INFORMATION PURPOSES AND IS SUBJECT TO CHANGE WITHOUT NOTICE. A COMMENT FORM HAS BEEN INCLUDED AT THE END OF THIS PUBLICATION FOR READER'S COMMENTS. IF THE FORM HAS BEEN USED, COMMENTS MAY BE ADDRESSED TO THE DIRECTOR (SYSTEMS ), CENTRE FOR DEVELOPMENT OF TELEMATICS, 39, MAIN PUSA ROAD, NEW DELHI - 110 005 © 2003 BY C–DOT, NEW DELHI. Table of Contents Chapter 1. Introduction ..............................................................................................................................5 Chapter 2. Packaging Details .....................................................................................................................6 Chapter 3. Cable Preparation & Laying ....................................................................................................8 3.1. Subscriber cable (Internal to the System) ....................................................................8 3.2. Digital Trunk Cable (Internal to System) ..................................................................11 3.3. Power Cable ..................................................................................................................13 3.4. PC Interface Cable Assembly ......................................................................................15 3.5. Fan Cable (Internal Cable)..........................................................................................17 3.6. Internal Cable Routing ................................................................................................21 Chapter 4. Integration with Network ......................................................................................................26 Appendix - 1 Jumper Settings .....................................................................................................................27 Appendix - 2 Specification of PC..................................................................................................................28 Appendix - 3 Software Installation of IVRS................................................................................................30 Appendix - 4 Data Creation for IVRS Routes in C-DOT Systems .............................................................32 Appendix - 5 IOP - PC Connectivity for Line Testing ................................................................................34 Appendix - 6 Interface with Servers............................................................................................................35 Appendix - 7 Power Feed in Case of Non-Availability of N48V.................................................................37 H:\HOME\IVRS\IVRSINMN.DOC April 26, 2004 Chapter 1. Introduction C-DOT Interactive Voice Response System (IVRS) can be easily integrated with the existing telecom network. It can be interfaced with the network through the normal twisted pair copper wire (analog line) or through E1 trunk interface (Digital --> 2Mbps). Junction cards are used for analog interface and E1 trunks (maximum of 2) can be interfaced through Compact Terminal Controller (CTC) card. The system can cater up to 60 channels simultaneously and can be configured to support many applications with flexibility in the number of ports assigned to each application. The system is designed with state of the art Digital Signal Processing (DSP) technology. INSTALLATION MANUAL 5 Chapter 2. Packaging Details The C-DOT IVRS is available in the following configurations. 1. 30 channel IVRS : Using 4 nos. of junction cards or 1 no. of E1 trunk 2. 60 channel IVRS Using 4 nos. of junction cards and 1 no. of E1 trunk or Using 2 nos. of E1 trunks The system has the following cards 1. APC-CTCA01/0-S11 2. APC-ASVA27/H-B00 3. APC-JUN081/T-S03 4. APC-EPU874/F-S02 5. APC-IXCA49/T-S01 (Auxillary card) 6. APC-IVBA47/F-M00 (Backplane) The quantity of JUN & ASV cards are site dependent. Atleast one each of, ASV, CTC and EPU should exist for E1 interface and additionally JUN card and for analog interface alongwith RS232 cables to bring up the system. 6 C-DOT IVRS PACKAGING DETAILS IVRS HARDWARE EUIPAGE 1 E P U 2 3 4 5 6 J U N 0 J U N 1 J U N 2 J U N 3 7 8 9 10 A S V 0 A S V 1 11 12 13 C T C Fig. 2.1 Note : One ASV for 30ch is required subject to 2 cards max. Use of JUN depends on the type of I/F provided at site. INSTALLATION MANUAL 7 Chapter 3. Cable Preparation & Laying In this chapter, preparation of various cables at site are discussed. Certain cables are prepared in the factory for which the length is known. The details of all types of cables are covered in this chapter. 3.1. 8 SUBSCRIBER CABLE (Internal to the System) C-DOT ASSY. NO. : ACB-IVRJCMD0-000 DRAWING NO. : Fig. 3.1.1 CABLE PART NO. : MCA-ICSBZ010-401 CABLE MARKER NO. : AAYY CABLE DESCRIPTION : 32 Pair cable (4 x 8 pair twisted cable) CABLE LENGTH : Fixed. Ref. Fig. 3.1.1 SOURCE TERMINATION PART NO. : MCC-BPCSZ001-301 DESTINATION TERMINATION PART NO. : MCC-MDFPZ027-301 SOURCE PLACEMENT : As per Table : 3.1.1 TAB. NO. RETAINED (POLARISATION) : MODULE 1 : 1 MODULE 2 : 2 DESTINATION PLACEMENT : MDF in system TAB. NO. RETAINED : - ASSEMBLY PROCEDURE : Refer Fig. 3.1.2 C-DOT IVRS INSTALLATION MANUAL 3 SYSTEM SIDE 4 VIEW `A' 2 1 BROWN BLUE 3 4 BL AA06 AA05 AA04 BR AA03 WH YL WHITE H BR AA 03 W CABLE MARKER YELLOW ABBR. 1 COLOUR CABLE UNIT AA06 2 SL. NO. TABLE 3.1.1 BL AA05 YL CABLE TIE SLOT 6A POSITION 1,2 SLOT 5A POSITION 1,2 SLOT 4A POSITION 1,2 SLOT 3A POSITION 1,2 SOURCE AA04 (SEE TABLE) MDF IN SYSTEM DESTINATION 03-06 01-02 SUBSCRIBER CABLE SYSTEM TO MDF IN THE MCA-ICSBZ010-401 32 PAIR CABLE REFER DOCUMENT ACB-IVRJNMD0-000 (GA) DIGITAL TRUNK CABLE YY VALUES TAKES VALUE FROM 01 TO 06 WHERE \DESIGN\IVRS-IM\IVRSIM-CLA MODULE 2:2 2. POLARISATION TAB No. TO BE RETAINED = MODULE 1:1 1. THE FIRST MODULE IN THE 2 MODULE HOUSING CATERS TO 7 PAIRS WHEREAS THE SECOND MODULE CATERS TO ONE PAIR. NOTE: SPARE PAIRS COILED UNDER INSULATION TAPE / RUBBER GROMMET VIEW - A AA YY FIG. 3.1.1 (TYP) 8 PAIR CABLE UNIT 2 MODULE CONNECTOR ASSEMBLY CABLE PREPARATION & LAYING 9 FIG. 3.1.2 \DESIGN\IVRS-IM\IVRSIM-SCLA Chapter 3. 10 C-DOT IVRS CABLE PREPARATION & LAYING 3.2. DIGITAL TRUNK CABLE (Internal to System) C-DOT ASSY. NO. : ACB-IVRJNMD0-000 DRAWING NO. : Fig. 3.2.1 CABLE PART NO. : MCA-PVCTPS08-401 CABLE MARKER NO. : AAXX CABLE DESCRIPTION : Shielded twisted pair digital cable CABLE LENGTH : Fixed. Ref. Fig. 3.2.1 SOURCE TERMINATION PART NO. : MCC-BPCSZ001-301 DESTINATION TERMINATION PART NO. : MCC-MDFPZ027-301 SOURCE PLACEMENT : As per Table : 3.2.1 TAB. NO. RETAINED : TAB NO. 1 FOR MODULE 1 TAB NO. 2 FOR MODULE 2 DESTINATION PLACEMENT : MDF TAB. NO. RETAINED : - ASSEMBLY PROCEDURE : Refer Fig. 3.2.1 INSTALLATION MANUAL 11 12 1 2 3 AA02 AA01 3 4 MCA-CBLTZ00-401 CABLE TIE WHITE WHITE WHITE WHITE BLUE ORANGE GREEN BROWN GREY BLUE ORANGE GREEEN 1 3 5 7 1 3 5 7 RED RED RED WHITE `C' ROW `A' ROW HDB3 IN HDB3 OUT HDB3 IN HDB3 OUT HDB3 IN HDB3 OUT HDB3 IN HDB3 OUT SIGNAL NAME TABLE 3.2.1 : WIRING DETAILS MODULE 2 2 CABLE PIN MARKER NO. 4 1 MODULE 1 SEE NOTE 2 SYSTEM FRAME (SLOT-2) CONNECTOR A SLOT-2 CONNECTOR A SOURCE PLACEMENT 15 Cms AA02 AA01 MDF IN SYSTEM DESTINATION PLACEMENT MCA-PVCTPS08-401 SHIELDED TWISTED PAIR DIGITAL CABLE 25 Cms MCC-BPWCB207-401 FIG. 2 THE WIRE LENGTH SHALL BE AS SHOWN IN THE FIGURE. 4. 6. DTK 0:1 OF RWC-1 OR DTK 2:3 OF EDT DTK 0:1 OF RWC-0 OR EDT FIG. 3.2.1 POSITION 3 - DTK 4:5 POSITION 2 - DTK 2:3 POSITION 1 - DTK 0:1 OF CTC PLACEMENT AT SLOT-2 CONNECTOR 'A' DEPENDS ON SYSTEM CONFIGURATION MODULE 1:2, MODULE 2:3 POLARITY TABS TO BE RETAINED AS GIVEN BELOW SOLDER 32/0.2 MM MULTISTRAND WIRE ON TO THE SHIELD (COPPER BRAID) AT THE POINT SHOWN AND CRIMP,RING TERMINAL AS SHOWN ON TO THE OTHER END. 3. 5. SNAP THE HOOD (FIG. 2) ON TO THE CONTACT BLOCK (FIG. 1) SUCH THAT POLARITY TAB (1) IS TOWARDS PIN 1 AS PER WIRING DONE. 2. CHASSIS END \DESIGN\IVRS-IM\IVRSIM-CLA1 MCT-ERRIN017-401 NI 2.5 mm /M6/16 2 MCA-PVCSC512-401 32/0.2mm GREEN TO MDF IN THE SYSTEM 10 Cms RING TERMINAL POLARISED HOOD MCC-BPPOH207-401 1. WIRE WRAP THE PAIRS ON TO CONTACT BLOCK PINS (FIG. 1) OF EACH MODULE AS PER WIRING DETAILS GIVEN. NOTE: FIG. 1 CONTACT BLOCK (WIRE WRAP TYPE) Chapter 3. C-DOT IVRS CABLE PREPARATION & LAYING 3.3. POWER CABLE C-DOT ASSY. NO. : ACB-MAXLPPA3-000 DRAWING NO. : Fig. 3.3.1 CABLE PART NO. : MCA-PVCMC041-401 CABLE MARKER NO. : AXMC CABLE DESCRIPTION : 4 Core multistrand 16/0.2 PVC insulated CABLE LENGTH : 15M SOURCE TERMINATION PART NO. : 1. 2. CONN FEM MATE-N-LOCK 4P MCC-MLFSX202-000 CRIMP PINS FEM MCC-MPFSC001-000 DESTINATION TERMINATION PART NO. : Stripped wire SOURCE : IVRS Auxiliary card APC-IXCA491T-SXX TAB. NO. RETAINED (POLARISATION) : DESTINATION : TAB. NO. RETAINED : ASSEMBLY PROCEDURE : INSTALLATION MANUAL N48V MCB Refer Fig. 3.3.1 13 14 CRIMP PIN FEM. MCC-MPFSC001-000 TO VMS AUX. CARD (AX) YELLOW YELLOW-GREEN BLUE 2. 3. 4. N48V CH.-GND D-GND N48V-GND VOLTAGE FIG. 3.3.1 RED 1. TABLE : 3.3.1 CABLE COLOUR PIN No. TABULATION FOR CONNECTIVITY: AXMC CABLE MARKER CONN. FEM MATE-N-LOCK 4P MCC-MLFSX202-000 15m LENGTH TO MCB (N48V) (MC) \DESIGN\IVRS-IM\IVRSIM-AXMC AXMC 4 CORE MULTISTRAND 16/0.2 PVC INSLT.. (LENGTH AS PER SITE REQUIREMENT) MCA-PVCMC041-401 Chapter 3. C-DOT IVRS CABLE PREPARATION & LAYING 3.4. PC INTERFACE CABLE ASSEMBLY C-DOT ASSY. NO. : ACB-IVRACPC0-000 DRAWING NO. : Fig. 3.4.1 CABLE PART NO. : MCA-PVCMC031-401 CABLE MARKER NO. : ACPC CABLE DESCRIPTION : 3 Core multistrand 16/0.2 CABLE LENGTH : 20M (Max) SOURCE TERMINATION PART NO. : 1. DTYPE 9P FEM CONN SLDR BKT MCC-DCFXST09-000 2. DTYPE 9 PIN HOOD MCC-DHXXXT09-100 1. DTYPE 9P MALE CONN SLDR BKT MCC-DCMXST09-000 2. DTYPE 9 PIN HOOD MCC-DHXXXT09-100 DESTINATION TERMINATION PART NO. : SOURCE PLACEMENT : TAB. NO. RETAINED (POLARISATION) : DESTINATION PLACEMENT : TAB. NO. RETAINED : ASSEMBLY PROCEDURE : INSTALLATION MANUAL IVRS Auxiliary Card APC-IXCA49/T-SXX PC - RS232C SERIAL PORT Refer Fig. 3.4.1 15 16 5 1 9 6 5 5 GND 20m (MAX.) ASV0 ASV1 J1 J2 SOURCE TO BE CONNECTED AT AUXILIARY CARD ACPC FIG. 3.4.1 PC I/F CABLE FOR ASV & ASV1 TO PC GREEN RED BLACK LENGTH CABLE MARKER COLOUR OF WIRE ACPC (* NO. OF PC I/F CABLE REQUIRED = NO. OF ASV CARD EQUIPPED IN A IVRS SYSTEM) 3 3 Tx 2 2 Rx PC AC (DTYPE FEM) (DTYPE MALE) TABULATION FOR CONNECTIVITY: TO PC (PC) D TYPE 9P MALE CONN. SLDR BKT WITH D TYPE 9P HOOD D TYPE 9P FEM CONN. SLDR BKT MCC-DCMXST09-000 WITH D TYPE 9P HOOD MCC-DHXXXT09-100 MCC-DCFXST09-000 MCC-DHXXXT09-100 3 CORE MULTISTRAND 16/0.2 (LENGTH AS PER SITE REQUIREMENT) MCA-PVCMC031-401 \DESIGN\IVRS-IM\IVRSIM-PCCL TO IVRS AUXILLIARY CARD (AC) Chapter 3. C-DOT IVRS CABLE PREPARATION & LAYING 3.5. FAN CABLE (Internal Cable) FAN 1 : C-DOT ASSY. NO. : ACB-IVRSF1AX0-000 DRAWING NO. : Fig. 3.5.1 CABLE PART NO. : - CABLE MARKER NO. : FIAX CABLE SPECIFICATION : - CABLE LENGTH : 60 cms (Sleeve length = 60 cms) SOURCE TERMINATION PART NO. : 1. INSTRUMENT COOLING FAN MCT-MPFAS004-401 2. SLEEVE SPIRAL 3 mm DIA MCV-CLSSZ001-401 1. CONN S/R 3P FEM HOUSING MCC-SPFSCT03-000 2. CRIMP PINS MCC-PIFSC000-001 DESTINATION TERMINATION PART NO. : SOURCE PLACEMENT : TAB. NO. RETAINED (POLARISATION) : DESTINATION PLACEMENT : TAB. NO. RETAINED : ASSEMBLY PROCEDURE : INSTALLATION MANUAL INSTRUMENT COOLING FAN IVRS Auxiliary Card (FAN1-J11) APC-IXCA49/T-SXX - 17 18 CABLE LENGTH FOR FAN 1 = 60cms. SLEEVE LENGTH AS PER CABLE LENGTH. NOTE: 3 BLACK WIRE 2 1 WHITE WIRE SLEEVE SPIRAL 3mm Dia. MCV-CLSSZ001-401 RED WIRE FIG. 3.5.1 COOLING FAN CABLE F1AX CABLE MARKER INSTRUMENT COOLING FAN MCT-MPFAS004-401 \DESIGN\IVRS-IM\IVRSIM-FCL CRIMP PINS MCC-PIFSC000-001 CONN. S/R 3P FEM. HOUSING MCC-SPFSCT03-000 Chapter 3. C-DOT IVRS CABLE PREPARATION & LAYING FAN 2 : C-DOT ASSY. NO. : ACB-IVRSF2AX0-000 DRAWING NO. : Fig. 3.5.2 CABLE PART NO. : - CABLE MARKER NO. : F2AX CABLE SPECIFICATION : - CABLE LENGTH : 75 cms (Sleeve length = 75 cms) SOURCE TERMINATION PART NO. : 1. INSTRUMENT COOLING FAN MCT-MPFAS004-401 2. SLEEVE SPIRAL 3 mm DIA MCV-CLSSZ001-401 1. CONN S/R 3P FEM HOUSING MCC-SPFSCT03-000 2. CRIMP PINS MCC-PIFSC000-001 DESTINATION TERMINATION PART NO. : SOURCE PLACEMENT : TAB. NO. RETAINED (POLARISATION) : DESTINATION PLACEMENT : TAB. NO. RETAINED : ASSEMBLY PROCEDURE : INSTALLATION MANUAL INSTRUMENT COOLING FAN IVRS Auxiliary Card (FAN2-J10) APC-IXCA49/T-SXX - 19 20 NOTE: BLACK WIRE 3 2 1 WHITE WIRE SLEEVE SPIRAL 3mm Dia. MCV-CLSSZ001-401 RED WIRE FIG. 3.5.2 COOLING FAN CABLE CABLE LENGTH FOR FAN 2 = 75cms. SLEEVE LENGTH AS PER CABLE LENGTH. F2AX CABLE MARKER INSTRUMENT COOLING FAN MCT-MPFAS004-401 \DESIGN\IVRS-IM\IVRSIM-ECC1 CRIMP PINS MCC-PIFSC000-001 CONN. S/R 3P FEM. HOUSING MCC-SPFSCT03-000 Chapter 3. C-DOT IVRS CABLE PREPARATION & LAYING 3.6. INTERNAL CABLE ROUTING i) Fan cable routing Refer Fig. 3.6.1 ii) MDF cable routing Ref. Fig. 3.6.2 iii) Backmount wiring details for subscriber and trunk cables Ref. Fig. 3.6.3 iv) External cable routing Ref. Fig. 3.6.4. INSTALLATION MANUAL 21 INSTRUMENT COOLING FAN MCT-MPFAS004-401 22 \DESIGN\IVRS-IM\IVRSIM-FCR FIG. 3.6.1 FAN CABLE ROUTING (REAR VIEW) FAN-2 ASU-IVRECAF2-000 MCA-CBLTZ001-401 CABLE TIE 100mm NON-RELEASABLE FAN-1 ASU-IVRECAF1-000 CABLE TIE 100mm NON-RELEASABLE Chapter 3. C-DOT IVRS INSTALLATION MANUAL RUBBER GROMETS ARE TO BE PLACED AT THE CABLE ENTRY POINTS IN THE BACK MOUNT FRAME OF MDF NOTE :- \DESIGN\IVRS-IM\IVRSIM-MCR FIG. 3.6.2 MDF CABLE ROUTING (REAR VIEW) IVRS AUXILIARY CARD APC-IXCA49/T-SXX IVRS MOTHERBOARD APC-IVBA47/F-MXX DIGITAL TRUNK CABLE ASSY ACB-IVRJNMD0-000 SUBSCRIBER CABLE ASSY ACB-IVRJCMD0-000 TO BE GROUNDED TO THE MOUNTING HOLE OF THE MDF MDF ASSEMBLY CABLE PREPARATION & LAYING 23 Chapter 3. FIG. 3.6.3 BACKMOUNT WIRING DETAIL FOR SUBSCRIBER AND TRUNK CABLE (TOP SIDE OF IVRS) \DESIGN\IVRS-IM\IVRSIM-BWD 24 C-DOT IVRS INSTALLATION MANUAL PC I/F CABLE ASSY \DESIGN\IVRS-IM\IVRSIM-ECC C FIG. 3.6.4 EXTERNAL CABLE ROUTING (REAR VIEW) TO COM2 OF PC AXM TO MCB N48V A X MC ACB-IVRACPC0-000 POWER CABLE ASSY ACB-IVRAXMC0-000 CABLE PREPARATION & LAYING 25 Chapter 4. Integration with Network It is assumed that the user has received the system in the following manner : ♦ Motherboard fixed to the card frame. ♦ Fans & MDF mounted in the system ♦ Subscriber & Trunk Lines routed from motherboard to MDF. ♦ Auxiliary card placed in slot no. 14 (Motherboard backside). • All other cards (CTC, ASV, EPU, JUN), Power and RS232 cables are available. N/W DIAGRAM PC C-DOT IVRS PSTN N/W ! TGP Routes between IVRS & PSTN switch ! ! ! Fig. 4.1 The IVRS must be connected to the switch using analog/digital trunk with standard trunk group parameters. Routes for different applications in IVRS are to be created in the switch side. Please refer to IVRS user manual for administration/data creation of IVRS applications in the PC. The application software installation procedure is explained in Appendix-3 of this installation manual. 26 C-DOT IVRS Appendix - 1 Jumper Settings 1. 2. APC-ASVA27/H-B00 Position Pins to be shorted W4 1-2 W5 (Not used) W6 2-3 APC-CTCA01/O-S11 W1 ! Open when EPROM is used W1 ! To be shorted when EPROM is not used (Flash is used) INSTALLATION MANUAL 27 Appendix - 2 Specification of PC • INTEL Pentium-IV or latest @1.2GHz or above • 256MB SDRAM and above (expandable) • Minimum 4 PCI and 1 AGP Slots • 40 GB SCSI/IDE Hard Disk or above • 4MB AGP Card or above or inbuilt display card • 104-Key Windows’98 Keyboard or above • Two RS-232 Serial Ports (4 COM PORTS optional) • One Enhanced Parallel Port EPP / ECP • PS/2 or USB Mouse Port • 1 Microsoft Mouse (PS/2) or USB • 15” SVGA Colour Monitor (Non-Interlaced) • 1 Ethernet interface Card 10/100 Mbps Autosensing with 2 PORTS (optional – for Fault Reporting System interface) • 1.44 MB FDD • 52x and above CD ROM or equivalent DVD Drive • Ultra Wide PCI SCSI Card – 1 No.(optional) • 1.2 GB Cartridge Tape or DAT Drive (optional-for back-up) • PC Microphone (for recording announcements) • Multimedia Kit (for announcements and playback) with in built or add on Sound Card and Speakers. • 2 MODEMS – Class 2 or above for Line Testing and FAX (Optional) • Windows NT 4.0 work station with all latest service packs/ Windows 2000 Professional with all latest service packs. • WINFAXPRO 10.0 or latest version (SYMENTEC).(optional for faxing) .” . SPECIFICATION OF UPS (Uninterrupted Power Supply) FOR PC 28 C-DOT IVRS SPECIFICATION OF PC • Online UPS of rating 0.5 KVA (MINIMUM) POWER SOURCE FOR SYSTEM HARDWARE (Optional) • AC-DC converter with -48V 2A output - connected to UPS (in case -48V is not available). INSTALLATION MANUAL 29 Appendix - 3 Software Installation of IVRS Insert IVRS installation CD in CDROM drive and open the windows explorer a) Installing C-DOT IVRS Application 1. Go to the folder Net setup and double click the setup icon. 2. Select 'continue' to install the IVRS application. 3. Enter the Name of the Supervisor and the Organisation then click 'OK'. 4. Select 'OK to confirm the name of the supervisor and the organization. 5. Accept the default folder displayed by the setup program (i.e. cdotivrs). The drive can be changed to d: or e: as required. 6. Press the personal computer icon to install all files for IVRS. 7. Choose the default program group (CDOT IVRS) and press 'continue'. 8. If C-DOT IVRS has been installed in a folder other than C:\CDOTIVRS, then change the file properties of cltrans.pif file after installation. 9. b) 30 i) Right click the cltrans.pif file, click properties ii) Go to the program tab, change the command line parameter to the folder where you have installed CDOT IVRS. Select restart windows when prompted. Creating Data Source Names 10. Run the obdcsetup.exe file from cdotivrs folder. 11. Enter the full path where cdotivrs application is installed, as given in step 5 earlier, for example, C:\cdotivrs. 12. Enter the full path where commandir application is installed, for example, e:\comtran. C-DOT IVRS SOFTWARE INSTALLATION OF IVRS c) 13. Enter the full path where subscriber master file is available. For example, e:\tele 14. Click the 'Go' button and go through the list box to know whether all data sources have been created successfully or not. Failed ones are shown as "not done". It means that drivers are not installed properly. To install the drivers again repeat the process from step1. Importing the Registry 15. d) e) Go to the cdotivrs folder and double click the cdotivrs.reg file. Installing the FAX Software 16. Go to winfac folder and double click the setup icon. 17. Select "Agree". 18. Select all default values and make sure modem is connected and is turned on. 19. Select Restart windows when prompted. Executing the Application Before running the application make sure that all the data sources are created properly as told in step (b). 20. Run the cdotivrs.exe and configure the system by equipping the Junction cards/DTK and map the ports to the required applications 21. Run the cdotlinetester.exe only if any of the ports are mapped to FCS application. 22. Run dataman.exe to see log reports and to input data to the system. * INSTALLATION MANUAL Create a batch file that copies submas.dbf from Novell server to cdotivrs server and put this batch file in scheduler with frequency everyday. 31 Appendix - 4 Data Creation for IVRS Routes in C-DOT Systems • Identify the analog/digital trunks which are free. • The trunk group can be created as follows in crp, <cre-tgp 32 TGP-NO : XX TGP-NAME : IVRS-OG TGP-STA : OG LIN-SIG : DR2-CAS3 for Digital Trunk REG-SIG : MOD-R2 [MF-SIG] : Fully Compelled [CGS-NO] : ↵ [CGS-NAME] : ↵ [ROD] : 1 [Trunk-Priority] : ↵ [Prefix-Digits] : ↵ [Pad-Lev] : ↵ [TGP-TYP] : Ord [CAMA] : ↵ [TGP-FACILITY] : ↵ [DGT-SZFD] : ↵ [RNG-DWN] : ↵ [DIAL-TON] : ↵ C-DOT IVRS DATA CREATION FOR IVRS ROUTES IN C-DOT SYSTEMS AC-STA : 2 WP [AC-INFO] : ↵ [TGP-CAT] : ↵ [HNT-TYP] : ↵ [SIG-INF] : ↵ [CONF-CHK] : ↵ [ECHO-SUP] : ↵ [SAT-IND] : ↵ TEN : BM-RACK-FRM-SLOT-CKT [TEN-NO7] : ↵ EXECUTE Route : <cre-rout : ROUT-CODE : 198 (Say) Rout-Flag : 1 - cnb-na-ga 2 - cnb-na-ga Crg-rtn : 1-x* & 2-x & . . . Dig-LGT : 3 TGP-choice : 1-y & 9-y & 10-y & 12-y Execute y - TGP towards IVRS x! Crg-rate-no with/without charging +NRML RING * - Depends on the service (Charging) Routes for other services like Billing Enquiry Service, Payment Reminder Service, changed no. announcement, etc are to be created in the similar manner. An incoming trunk group is also to be created for calls from IVRS to the system. The tgp data is similar to that of the O/G tgp except the tgp-status parameter which is to be defined as incoming. INSTALLATION MANUAL 33 Appendix - 5 IOP - PC Connectivity for Line Testing • This can be done by connecting the IOP serial port and the PC comm. port with the help of a RS232 cable. The system (IOP) should have an opr account named as 'ivrs' and passwd 'ivrs'. This can be created as follows : <Add-opr 34 Opr-Name : ivrs Grp-Name : admin New-Pwd : ivrs Ver-Pwd : ivrs A-Class : 9 (Charge calendar Mgmt display) & 22 (command file related commands) M-Class : 7 [tst-trm] Terminal maintenance routining commands C-DOT IVRS Appendix - 6 Interface with Servers 1. Interface with Commandir Server The IVRS PC can be made as part of the commandir network so that data updation can be carried out in the commandir server from IVRS PC. The connectivity is shown in Fig. A6.1. Please refer to Annexure-D of IVRS user manual for further details on this. IVRS PC HUB COMMANDIR SERVER T1 T2 T3 TERMINALS Fig. A6.1 Establish the connection between NT machine and the Novell Server using GSNW (Gateway Client Service for Netware) service which is available in Control Panel. (You should be able to access the Novell Server from NT Machine). Log on to the Novel Server and map SYS: to some drive (say F:) INSTALLATION MANUAL 35 Appendix 2. Interface with TRA Server I V R S PC T R A Server RS232 Fig. 6.2 The IVRS PC can be interfaced or the TRA server through the COM Port. This can be used for data porting (transfer). For this Teraterm software is to be installed in the PC. Please refer IVRS user manual for further details on this. 36 C-DOT IVRS Appendix - 7 Power Feed in Case of Non-Availability of N48V In certain circumstances it may be required to install the IVRS where N48V supply is not available. In such cases, an adapter (which converts 230V AC into -48 DC) can be used to cater the power requirement of IVRS. The setup is shown in Fig. 7.1. POWER FEED IN CASE OF NON AVAILABILITY OF N48V AC 230V AC DC C-DOT IVRS Converter 48V * PC * Range ! 42V to -56V Fig. 7.1 INSTALLATION MANUAL 37 System Practices COMMENTS The following comments pertain to: Document Name CSP Section - Issue/Draft , No. - (Month) (Year) COMMENTS : (Use a separate sheet if required) Please mail your comments to: Centre for Development of Telematics Attn: Director, Systems 39, Main Pusa Road New Delhi 110 005 Tel.: +91-11-25740374 Fax: +91-11-25756378 Your Reference: Name : Designation : Company : Address : Tel. : Fax :