Download Safety Control Unit

Transcript
When not using the start switch
(Auto start)
Auto start
When connecting multiple emergency stop switches in
series
24V DC
T4
X4
T5
X5
X16
X17
T12
X12
T13
X13
When not detecting the welding of start
switch
Manual start)
Start
(Manual
NOTE: Applicable safety performance is dependent
upon each system configuration.
24V DC
S7
X16
X17
When not using some safety inputs
24V DC
When detecting the welding of start
switch
Control start
(Control start)
24V DC
S7
X16
X17
T0
X0
T1
X1
T2
X2
T3
X3
T4
X4
T5
X5
T12
X12
T13
X13
Note: When using a spring lock type safety switch for a safety input of the SG-ONE, if the solenoid output
of SG-ONE is connected to the solenoid power terminal of the safety switch directly, then the start
condition cannot be established due to the safety input staying in the OFF state. In this case, connect the
switch or other equipment to the solenoid output of SG-ONE, and use the OFF operation of the solenoid
for lock control.
5-27