Download Wolf (BL2600)

Transcript
Each high-current output has its own +K supply. When wiring the high-current outputs,
keep the distance to the power supply as short as possible.
GND
+HK0
HOUT0
GND
+HK1
HOUT1
GND
+HK2
HOUT2
GND
+HK3
HOUT3
GND
CAUTION: If you are using a BL2600 with the IDC header connectors, beware that
an individual IDC header pin can only handle up to 1 A. Since the same high-current
outputs are available on opposite pairs of IDC header connectors, you can still use the
2 A sinking or sourcing capability of the BL2600 by wiring all your connections,
including the ground, in parallel to the opposite pairs (see Figure 10 for an example).
+HK0
GND
+HK0
HOUT0
GND
+HK1
HOUT1
GND
+HK2
HOUT2
GND
+HK3
HOUT3
GND
J13
0
1
2
3
Figure 10. Example of Wiring HK0 In Parallel on IDC Header
For the H bridge, which is shown in Figure 11, Ka and Kb should be the same.
+Ka
A
B
+Kb
LOAD
B
A
Figure 11. H Bridge
User’s Manual