Download Wolf (BL2600)
Transcript
3.2 Digital I/O 3.2.1 Digital Inputs The BL2600 has 16 digital inputs, DIN16–DIN31, each of which is protected over a range of –36 V to +36 V. The inputs are factory-configured to be pulled up to +5 V, but they can also be pulled up to +K or DCIN, or pulled down to 0 V in banks by changing a jumper as shown in Figure 7. DCIN +5 V +3.3 V +K 27 kW 100 kW Rabbit 3000® Microprocessor GND Figure 7. BL2600 Digital Inputs DIN16–DIN31 [Pulled Up—Factory Default] Table 2 lists the banks of digital inputs and summarizes the jumper settings. Table 2. Banks of BL2600 Digital Inputs Digital Inputs Header Pins Jumpered Pulled Up/Pulled Down DIN16–DIN19 JP3 1–2 Inputs pulled up to +5 V DIN20–DIN23 JP4 3–4 Inputs pulled up to DCIN DIN24–DIN31 JP5 5–6 Inputs pulled up to +K 7–8 Inputs pulled down to GND When you use the software digIn function call to read the digital inputs, DIN16–DIN31 are considered to be digital input channels 16–31. 14 Wolf (BL2600)