3 - CIP Device Profile
Table 81: Configuration Object Instance Attributes (Instance 1) (Continued)
Attribute ID
Name
72
Relay 1 Configuration
73
Relay 2 Configuration
74
Relay 3 Configuration
Description
Units:
Range: 0-22
0: Off
1: Fault Fail Safe
2: Fault Non-Fail Safe
3: Running
4: Up To Speed
5: Alarm
6: Ready
7: Locked Out
8: Over Current Alarm
9: Under Current Alarm
10: Overload Alarm
11: Shunt Trip Fail Safe
12: Shunt Trip Non Fail Safe
13: Faulted on Ground Fault
14: In Energy Saver Mode
15: Heating
16: Slow Speed
17: Slow Speed Forward
18: Slow Speed Reverse
19: DC Braking
20: Cooling Fan
21: PORT
22: Tach Loss
Data Type: UINT
Note:
MX2 0-20
Analog Input Trip Enable
Units:
Range:
0: Disabled
1: Enabled
Data Type: UINT
76
Analog Input Trip Type
Units:
Range:
0: Low - Fault below preset level
1: High - Fault above preset level
Data Type: UINT
77
Analog Input Trip Level
Units: %
Range: 0-100
Data Type: UINT
78
Analog Input Trip Delay Time
Units: 100 mSec
Range: 1-900
Data Type: UINT
79
Analog Input Span
Units: %
Range: 1-100
Data Type: UINT
80
Analog Input Offset
Units: %
Range: 0-99
Data Type: UINT
75
73