Download - Electro Systems Associates
Transcript
11.6 CONNECTOR DETAILS In all 11 lines are used as detailed below PIN NO ON J4 SIGNAL DIRECTION FROM ESA 86/88-2 DESCRIPTION PIN NO ON CENTRONICS CONNECTOR 5 (PCO) STROBE O/P STORBE* pulse to the printer 1 13(PB0) 14(PB1) 11(PB2) 12(PB3) 9(PB4) 10(PB5) 7(PB6) 8(PB7) Data 0 Data 1 Data 2 Data 3 Data 4 Data 5 Data 6 Data 7 O/P O/P O/P O/P O/P O/P O/P O/P These signals represent 8 bits of parallel data High = 1 Low = 0 2 3 4 5 6 7 8 9 16(PA7) BUSY I/P A high indicates that Printer cannot receive data. The signal becomes high in following cases a) During data entry b) During Printing operation c) In OFF-LINE states d) During printer error status 11 26 GND Signal ground 19 11.7 DIRECT OUTPUT TO PRINTER As already described, when the printer interface is enabled, any character sent to the console is sent to the printer also. This facility is available in the serial mode of operation only. However, user can access a routine "Print String", to send a string directly to the printer. This routine can be called from the user's program when the system is operating in either of the two modes - keyboard or serial. Further, this routine prints the string independent of the setting of SW7. Thus this routine can be used to print the desired information even when the system is running in the keyboard mode. However, to use this routine, user program must first initialize the 8255 at U27 to mode 0 with port A as input and Ports B and C as outputs (mode control byte is 90H.) The details of the routine "Print String" are given below: 11 - 3 ESA 86/88-2 User’s Manual