Download "user manual"

Transcript
10: SHIFT / ROTATE INSTRUCTIONS
WSFT (Word Shift)
WSFT
S1
*****
S2
*****
D1
*****
When input is on, N blocks of 16-bit word data, starting with device assigned by D1,
are shifted up to the next 16-bit positions. At the same time, the data assigned by
device S1 is moved to the device assigned by D1. S2 specifies the quantity of blocks to
move.
When S2 = 3 (quantity of blocks to shift)
S1
16-bit data
S1
16-bit data
D1+0
First 16-bit data
D1+0
D1+1
Second 16-bit data
D1+1
First 16-bit data
D1+2
Third 16-bit data
D1+2
Second 16-bit data
D1+3
Third 16-bit data
D1+4
Fifth 16-bit data
D1+3
Fourth 16-bit data
D1+4
Fifth 16-bit data
3 blocks (S2)
S1 data
Applicable SmartAXIS
FT1A-12
FT1A-24
FT1A-40
FT1A-48
FT1A-Touch
X
X
X
X
X
Valid Devices
Device
Function
I
Q
M
R
T
C
D
Constant
Repeat
S1 (Source 1)
Source data for word shift
X
X
X
X
X
X
X
X
—
S2 (Source 2)
Quantity of blocks to shift
X
X
X
X
X
X
X
X
—
D1 (Destination 1)
First device address to shift
—
—
—
—
—
—
X
—
—
For valid device address ranges, see "Device Addresses" on page 3-1.
When T (timer) or C (counter) is used as S1 or S2, the timer/counter current value (TC or CC) is displayed.
Valid Data Types
W (word)
X
I (integer)
—
D (double word)
—
L (long)
—
F (float)
—
When a bit device such as I (input), Q (output), M (internal relay), or R (shift register) is assigned as source S1 or
S2, 16 points are used.
When a word device such as T (timer), C (counter), or D (data register) is assigned as source S1 or S2, 1 point is
used.
Special Internal Relay M8024: BMOV/WSFT Executing Flag
While the BMOV or WSFT is executed, M8024 turns on. When completed, M8024 turns off. If the CPU is powered down while
executing BMOV or WSFT, M8024 remains on when the CPU is powered up again.
Example: WSFT
SOTU
I0
WSFT
S1
D10
S2
3
D1
D100
Before shift:
D10
12345
D10
12345
D100
1111
D100
12345
D101
2222
D101
1111
D102
3333
D102
2222
D103
4444
D103
3333
D104
5555
D104
5555
D100 through D102  D101 through D103
D10  D100
When input I0 is turned on, data of 3 data registers, starting with D100 assigned by
destination device D1, is shifted to the next data registers. Data of data register D10,
assigned by source device S1, is moved to D100 assigned by destination device D1.
After first shift:
SMARTAXIS LADDER PROGRAMMING MANUAL FT9Y-B1382
10-7