TECHNICAL BULLETIN [Issue No.] FA-A-0059 [Page] 21/22 [Title] Product discontinuation of the A1SD51S intelligent communication module [Date of Issue] July 2009 [Relevant Models] A1SD51S 2) Program example y Initialization of a bar-code reader Single mode, initial setting Predefined protocol ready Protocol No.1 SSET: Change to setting mode. Initial setting execution command Protocol No.2 CODE: Set bar-code type. (CODE128) Protocol No.2 Stores send data. Code Number Bar Code Type Parameter Protocol No.3 WP12n: Set to Read mode. (single) Protocol No.3 Stores send data. Protocol No.4 SAVE: Saves the setting to EEP-ROM. Protocol No.5 SEND: Exits the setting mode. Executes CPRTCL instruction. Processing for normal completion Processing for error completion Stores an error code. Initial setting execution command OFF y Instruction for reading the bar-code reader Single mode execution Predefined protocol ready Protocol No.6 LON: Timing ON (Read ON) Read execution command CPRTCL instruction execution Processing for normal completion Processing for error completion Stores an error code. Read execution command OFF HEAD OFFICE : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN