Download MICROMASTER 440

Transcript
Issue B1
P2226[3]
Parameters
BI: Fixed PID setp. select Bit 4
CStat:
CT
P-Group: COMMANDS
Datatype: U32
Active: first confirm
Unit: QuickComm. No
Min:
Def:
Max:
0:0
722:4
4000:0
Level:
Min:
Def:
Max:
1
1
3
Level:
Min:
Def:
Max:
0:0
722:5
4000:0
Level:
Min:
Def:
Max:
0
0
1
Level:
3
Defines command source of fixed PID setpoint selection Bit 4
Settings:
722.0 = Digital input 1 (requires P0701 to be set to 99, BICO)
722.1 = Digital input 2 (requires P0702 to be set to 99, BICO)
722.2 = Digital input 3 (requires P0703 to be set to 99, BICO)
722.3 = Digital input 4 (requires P0704 to be set to 99, BICO)
722.4 = Digital input 5 (requires P0705 to be set to 99, BICO)
722.5 = Digital input 6 (requires P0706 to be set to 99, BICO)
Index:
P2226[0] : 1st. Command data set (CDS)
P2226[1] : 2nd. Command data set (CDS)
P2226[2] : 3rd. Command data set (CDS)
P2227
Fixed PID setpoint mode - Bit 5
CStat:
CT
P-Group: TECH
Datatype: U16
Active: first confirm
Unit: QuickComm. No
3
Direct selection / direct selection + ON Bit 5 for PID setpoint.
Settings:
1
Direct selection
2
Direct selection + ON command
3
Binary coded selection + ON command
P2228[3]
BI: Fixed PID setp. select Bit 5
CStat:
CT
P-Group: COMMANDS
Datatype: U32
Active: first confirm
Unit: QuickComm. No
3
Defines command source of fixed PID setpoint selection Bit 5
Settings:
722.0 = Digital input 1 (requires P0701 to be set to 99, BICO)
722.1 = Digital input 2 (requires P0702 to be set to 99, BICO)
722.2 = Digital input 3 (requires P0703 to be set to 99, BICO)
722.3 = Digital input 4 (requires P0704 to be set to 99, BICO)
722.4 = Digital input 5 (requires P0705 to be set to 99, BICO)
722.5 = Digital input 6 (requires P0706 to be set to 99, BICO)
Index:
P2228[0] : 1st. Command data set (CDS)
P2228[1] : 2nd. Command data set (CDS)
P2228[2] : 3rd. Command data set (CDS)
P2231[3]
Setpoint memory of PID-MOP
CStat:
CUT
P-Group: TECH
Datatype: U16
Active: Immediately
Unit: QuickComm. No
2
Setpoint memory
Settings:
0
PID-MOP setpoint will not be stored
1
PID-MOP setpoint will be stored (P2240 is updated)
Index:
P2231[0] : 1st. Drive data set (DDS)
P2231[1] : 2nd. Drive data set (DDS)
P2231[2] : 3rd. Drive data set (DDS)
Dependency:
If 0 selected, setpoint returns to value set in P2240 (setpoint of PID-MOP) after an OFF command
If 1 is selected, active setpoint is 'remembered' and P2240 updated with current value.
Details:
See P2240 (setpoint of PID-MOP)
P2232
Inhibit rev. direct. of PID-MOP
CStat:
CT
P-Group: TECH
Datatype: U16
Active: first confirm
Unit: QuickComm. No
Min:
Def:
Max:
0
1
1
Level:
2
Inhibits reverse setpoint selection when PID motor potentiometer is chosen either as a main setpoint of
additional setpoint (using P1000)
Settings:
0
Reserve direction is allowed
1
Reserve direction inhibited
Note:
Setting 0 enables a change of motor direction using the motor potentiometer setpoint (increase/decrease
frequency either by using digital inputs or motor potentiometer up/down buttons.
MICROMASTER 440 Parameter List
6SE6400-5BB00-0BP0
143