Download MICROMASTER 440
Transcript
Issue B1 P2226[3] Parameters BI: Fixed PID setp. select Bit 4 CStat: CT P-Group: COMMANDS Datatype: U32 Active: first confirm Unit: QuickComm. No Min: Def: Max: 0:0 722:4 4000:0 Level: Min: Def: Max: 1 1 3 Level: Min: Def: Max: 0:0 722:5 4000:0 Level: Min: Def: Max: 0 0 1 Level: 3 Defines command source of fixed PID setpoint selection Bit 4 Settings: 722.0 = Digital input 1 (requires P0701 to be set to 99, BICO) 722.1 = Digital input 2 (requires P0702 to be set to 99, BICO) 722.2 = Digital input 3 (requires P0703 to be set to 99, BICO) 722.3 = Digital input 4 (requires P0704 to be set to 99, BICO) 722.4 = Digital input 5 (requires P0705 to be set to 99, BICO) 722.5 = Digital input 6 (requires P0706 to be set to 99, BICO) Index: P2226[0] : 1st. Command data set (CDS) P2226[1] : 2nd. Command data set (CDS) P2226[2] : 3rd. Command data set (CDS) P2227 Fixed PID setpoint mode - Bit 5 CStat: CT P-Group: TECH Datatype: U16 Active: first confirm Unit: QuickComm. No 3 Direct selection / direct selection + ON Bit 5 for PID setpoint. Settings: 1 Direct selection 2 Direct selection + ON command 3 Binary coded selection + ON command P2228[3] BI: Fixed PID setp. select Bit 5 CStat: CT P-Group: COMMANDS Datatype: U32 Active: first confirm Unit: QuickComm. No 3 Defines command source of fixed PID setpoint selection Bit 5 Settings: 722.0 = Digital input 1 (requires P0701 to be set to 99, BICO) 722.1 = Digital input 2 (requires P0702 to be set to 99, BICO) 722.2 = Digital input 3 (requires P0703 to be set to 99, BICO) 722.3 = Digital input 4 (requires P0704 to be set to 99, BICO) 722.4 = Digital input 5 (requires P0705 to be set to 99, BICO) 722.5 = Digital input 6 (requires P0706 to be set to 99, BICO) Index: P2228[0] : 1st. Command data set (CDS) P2228[1] : 2nd. Command data set (CDS) P2228[2] : 3rd. Command data set (CDS) P2231[3] Setpoint memory of PID-MOP CStat: CUT P-Group: TECH Datatype: U16 Active: Immediately Unit: QuickComm. No 2 Setpoint memory Settings: 0 PID-MOP setpoint will not be stored 1 PID-MOP setpoint will be stored (P2240 is updated) Index: P2231[0] : 1st. Drive data set (DDS) P2231[1] : 2nd. Drive data set (DDS) P2231[2] : 3rd. Drive data set (DDS) Dependency: If 0 selected, setpoint returns to value set in P2240 (setpoint of PID-MOP) after an OFF command If 1 is selected, active setpoint is 'remembered' and P2240 updated with current value. Details: See P2240 (setpoint of PID-MOP) P2232 Inhibit rev. direct. of PID-MOP CStat: CT P-Group: TECH Datatype: U16 Active: first confirm Unit: QuickComm. No Min: Def: Max: 0 1 1 Level: 2 Inhibits reverse setpoint selection when PID motor potentiometer is chosen either as a main setpoint of additional setpoint (using P1000) Settings: 0 Reserve direction is allowed 1 Reserve direction inhibited Note: Setting 0 enables a change of motor direction using the motor potentiometer setpoint (increase/decrease frequency either by using digital inputs or motor potentiometer up/down buttons. MICROMASTER 440 Parameter List 6SE6400-5BB00-0BP0 143