Transcript
Parameters r0070 Issue B1 CO: Act. DC-link voltage Datatype: Float Min: Def: Max: Unit: V P-Group: INVERTER - Level: 3 Displays (unfiltered) DC-link voltage. Note: r0071 Used for process control purposes (in contrast to r0026 (actual DC-link voltage), which is filtered and is used to display the value on the BOP/AOP). Level: CO: Max. output voltage Min: Datatype: Float Unit: V Def: P-Group: CONTROL Max: - 3 Displays maximum output voltage. Dependency: Actual maximum output voltage depends on the actual input supply voltage. r0072 Unit: V Min: Def: Max: - Level: Datatype: Float Unit: % Min: Def: Max: - Level: Datatype: Float CO: Act. output voltage P-Group: CONTROL 3 Displays output voltage. r0074 CO: Actual modulation P-Group: CONTROL 4 Displays actual modulation index. r0075 The modulation index is defined as ratio between the magnitude of the fundamental component in the inverter phase output voltage and half of the dc-link voltage. Level: CO: Current setpoint Isd Min: Datatype: Float Unit: A Def: P-Group: CONTROL Max: - 3 Displays setpoint of flux generating current component. Dependency: Applies when vector control is selected in P1300 (control mode); otherwise, the display shows the value zero. Level: r0076 CO: Act. current Isd Min: Datatype: Float Unit: A Def: P-Group: CONTROL Max: - 3 Displays flux generating current component. Dependency: Applies when vector control is selected in P1300 (control mode); otherwise, the display shows the value zero. Level: r0077 CO: Current setpoint Isq Min: Datatype: Float Unit: A Def: P-Group: CONTROL Max: - 3 Displays setpoint for component of torque generating current. Dependency: Applies when vector control is selected in P1300 (control mode); otherwise, the display shows the value zero. Level: r0078 CO: Act. current Isq Min: Datatype: Float Unit: A Def: P-Group: CONTROL Max: - 3 Displays component of torque generating current. r0079 CO: Torque setpoint (total) Datatype: Float P-Group: CONTROL Unit: Nm Min: Def: Max: - Level: 3 Displays total torque setpoint. Dependency: Applies when vector control is selected in P1300 (control mode); otherwise, the display shows the value zero. Level: r0080 CO: Actual torque Min: Datatype: Float Unit: Nm Def: P-Group: CONTROL Max: - 4 Displays actual torque. 20 MICROMASTER 440 Parameter List 6SE6400-5BB00-0BP0