Download MICROMASTER 440

Transcript
Parameters
r0070
Issue B1
CO: Act. DC-link voltage
Datatype: Float
Min:
Def:
Max:
Unit: V
P-Group: INVERTER
-
Level:
3
Displays (unfiltered) DC-link voltage.
Note:
r0071
Used for process control purposes (in contrast to r0026 (actual DC-link voltage), which is filtered and is
used to display the value on the BOP/AOP).
Level:
CO: Max. output voltage
Min: Datatype: Float
Unit: V
Def:
P-Group: CONTROL
Max: -
3
Displays maximum output voltage.
Dependency:
Actual maximum output voltage depends on the actual input supply voltage.
r0072
Unit: V
Min:
Def:
Max:
-
Level:
Datatype: Float
Unit: %
Min:
Def:
Max:
-
Level:
Datatype: Float
CO: Act. output voltage
P-Group: CONTROL
3
Displays output voltage.
r0074
CO: Actual modulation
P-Group: CONTROL
4
Displays actual modulation index.
r0075
The modulation index is defined as ratio between the magnitude of the fundamental component in the
inverter phase output voltage and half of the dc-link voltage.
Level:
CO: Current setpoint Isd
Min: Datatype: Float
Unit: A
Def:
P-Group: CONTROL
Max: -
3
Displays setpoint of flux generating current component.
Dependency:
Applies when vector control is selected in P1300 (control mode); otherwise, the display shows the value
zero.
Level:
r0076
CO: Act. current Isd
Min: Datatype: Float
Unit: A
Def:
P-Group: CONTROL
Max: -
3
Displays flux generating current component.
Dependency:
Applies when vector control is selected in P1300 (control mode); otherwise, the display shows the value
zero.
Level:
r0077
CO: Current setpoint Isq
Min: Datatype: Float
Unit: A
Def:
P-Group: CONTROL
Max: -
3
Displays setpoint for component of torque generating current.
Dependency:
Applies when vector control is selected in P1300 (control mode); otherwise, the display shows the value
zero.
Level:
r0078
CO: Act. current Isq
Min: Datatype: Float
Unit: A
Def:
P-Group: CONTROL
Max: -
3
Displays component of torque generating current.
r0079
CO: Torque setpoint (total)
Datatype: Float
P-Group: CONTROL
Unit: Nm
Min:
Def:
Max:
-
Level:
3
Displays total torque setpoint.
Dependency:
Applies when vector control is selected in P1300 (control mode); otherwise, the display shows the value
zero.
Level:
r0080
CO: Actual torque
Min: Datatype: Float
Unit: Nm
Def:
P-Group: CONTROL
Max: -
4
Displays actual torque.
20
MICROMASTER 440 Parameter List
6SE6400-5BB00-0BP0