IMPORTANT For combined approval types Once a device of multiple approval type is installed, it should not be re-installed using any other approval types. Apply a permanent mark in the check box of the selected approval type on the certification label on the transmitter to distinguish it from unused approval types. 2.4.1 FM Approval a. FM Intrinsically Safe Type Caution for FM intrinsically safe type. (Following contents refer “DOC. No. IFM022-A12”) Note 2. Entity Parameters • Intrinsically Safe Apparatus Parameters [Groups A, B, C, D, E, F and G] Vmax = 30 V Ci = 6 nF Imax = 200 mA Li = 0 µH Pmax = 1 W * Associated Apparatus Parameters (FM approved barriers) Voc ≤ 30 V Ca > 6 nF Isc ≤ 200 mA La > 0 µH Pmax ≤ 1W • Intrinsically Safe Apparatus Parameters [Groups C, D, E, F and G] Vmax = 30 V Ci = 6 nF Imax = 225 mA Li = 0 µH Pmax = 1 W * Associated Apparatus Parameters (FM approved barriers) Voc ≤ 30 V Ca > 6 nF Isc ≤ 225 mA La > 0 µH Pmax ≤ 1 W • Entity Installation Requirements Vmax ≥ Voc or Uo or Vt, Imax ≥ Isc or Io or It, Pmax (or Po) ≤ Pi, Ca or Co ≥ Ci + Ccable, La or Lo ≥ Li + Lcable Note 3. Installation • Barrier must be installed in an enclosure that meets the requirements of ANSI/ISA S82.01. • Control equipment connected to barrier must not use or generate more than 250 V rms or V dc. • Installation should be in accordance with ANSI/ISA RP12.6 “Installation of Intrinsically Safe Systems for Hazardous (Classified) Locations” and the National Electric Code (ANSI/NFPA 70). • The configuration of associated apparatus must be FMRC Approved. • Dust-tight conduit seal must be used when installed in a Class II, III, Group E, F and G environments. • Associated apparatus manufacturer’s installation drawing must be followed when installing this apparatus. • The maximum power delivered from the barrier must not exceed 1 W. • Note a warning label worded “SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY,” and “INSTALL IN ACCORDANCE WITH DOC. No. IFM022-A12” Note 4. Maintenance and Repair • The instrument modification or parts replacement by other than authorized representative of Yokogawa Electric Corporation is prohibited and will void Factory Mutual Intrinsically safe and Nonincendive Approval. [Intrinsically Safe] Hazardous Location Class I, II, III, Division 1, Groups A, B, C, D, E, F, G Class 1, Zone 0 in Hazardous (Classified) Locations AEx ia IIC Pressure Transmitters + Supply – Nonhazardous Location Safety Barrier + + – – General Purpose Equipment + – F0204.ai IM 01C25A01-01E 2 Handling Cautions Note 1. Model EJX/EJA-E Series Differential, gauge and absolute pressure transmitters with optional code /FS1 are applicable for use in hazardous locations. • Applicable Standard: FM3600, FM3610, FM3611, FM3810 • Intrinsically Safe for Class I, Division 1, Groups A, B, C & D. Class II, Division 1, Groups E, F & G and Class III, Division 1, Class I, Zone 0 in Hazardous Locations, AEx ia IIC • Nonincendive for Class I, Division 2, Groups A, B, C & D. Class II, Division 2, Groups F & G and Class I, Zone 2, Groups IIC, in Hazardous Locations. • Outdoor hazardous locations: NEMA TYPE 4X • Temperature Class: T4 • Ambient temperature: –60 to 60°C 7 <2. Handling Cautions>