Download CPС152 User Manual
Transcript
CPС152 User Manual 3.1.2 Installation and configuration Purpose of IDE integrated devices: Master or Slave Table 3-3: Jumper Purpose of IDE integrated devices: Master or Slave Description X3 [1-2] Flash-drive: Primary Master Compact Flash: Primary Slave X4 [0-0] X5 [0-0] X3 [0-0] Flash-drive: Primary Slave Compact Flash: Primary Master X4 [1-2] X5 [0-0] X3 [0-0] Flash-drive: deactivated Compact Flash: Primary Master X4 [1-2] X5 [1-2] X3 [0-0] Flash-drive: deactivated Compact Flash: Primary Slave X4 [0-0] X5 [1-2] 3.1.3 Selection of power supply voltage for LCD panel (connection via KIB98102, XP15) Table 3-4: Selection of power supply voltage for LCD panel (connection via KIB98102, XP15) Jumper Description X6[1-2] There was a selection of voltage of +5 V for power supply of LCD panel, connected via KIB98102 module (XP15 connector of CPC152 module) X6[2-3] There was a selection of voltage of +3.3 V for power supply of LCD-panel, connected via KIB98102 module (XP15 connector of CPC152 module) 3.1.4 Switching of Power Fail signals, watchdog timer actuation, remote access to the line of CPU hardware reset Table 3-5: Switching of Power Fail signals, watchdog timer actuation, remote access to the line of CPU hardware reset Jumper Description X7[1-2] Switching of Power Fail signal to the line of CPU hardware reset X8[1-2] Switching of watchdog timer (WDT2) actuation signal to the line of CPU hardware reset (used for automatic switching to the BIOS backup copy in case of a boot failure while booting from the main copy) X9[1-2] Switching of external signal of a remote reset / interrupt (from XP17, XP18 connectors) to the line of CPU hardware reset October 2015 3-3