Download V201-E1-1 - Products
Transcript
Section CompoBus/D Master Function 1-6 Software Switches Bit Not used. Enable Scan List Clear Scan List Clear Communications Error Stoppage Start Remote I/O Communications Stop Remote I/O Communications Status Area IR Area First word + 1 First word + 2 Master Status Area 1 (1 word) Registered Slave Information Area (4 words) First word + 6 Normal Slave Information Area (4 words) First word + 9 DM Area First word + 1 Master Status Area 2 (1 word) First word + 2 Current Communications Cycle Time (1 word) Master Status Area 1 This word contains flags that show the operating status of the network, the results of software switch operations, and current error data. Software switch operation results Operating status Operating status Error Data Bit Not used. Incorrect Switch Settings/ EEPROM Error Node Address Duplication/ Bus Off Error Detected Configuration Error Flag Setup Error Flag Transmission Error Flag Communications Error Flag Verification Error Flag Remote I/O Communications Stopped Status Flag Scan List Operation Completed Flag Scan List Operation Error Flag Communications Stoppage Cleared Flag Message Communications Enabled Flag Scan List Disabled Flag Error/Remote I/O Communications Stopped Flag Remote I/O Communications Flag 18