INSTALLATION INSTRUCTIONS
3.5 Installing the boiler
3.5.1 Minimum distances
L
X
Y
A
The appliance must be installed exclusively on a
vertical solid wall capable of supporting its weight.
H
The boiler should be fitted within the building unless
otherwise protected by a suitable enclosure i.e.
garage or outhouse. (The boiler may be fitted inside
a cupboard).
B
DISTANC ES [mm]
■ If the boiler is sited in an unheated enclosure then it
X
Y
200
200 495
L
H
A
B
1000
200
500
is recommended to leave the ON/OFF switch always
Fig. 1
in ON position to give frost protection.
A
■ If the boiler is installed in a room containing a bath
or shower reference must be made to the relevant
Balcony
requirements.
1200 m in.
Boilers can be installed externally, in a partially
protected place (balcony – see fig. 2) in
conformity with local Building Regulation and if
the outside minimum temperature is not lower
than –10°C. The manufacturer is not responsible
for external installations where the outside
A
SECTION A-A
temperature is lower than – 10°C or not in
conformity with above instructions.
MINIM UM D ISTANCE mm .
Fig. 2
In order to allow access to the interior of the boiler for
maintenance purposes, it is
important that the
minimum distances indicated in figure 1 are respected.