Download DCON_DLL - kolbinger electronic

Transcript
6.4.3
I-87K series modules
„ DigitalIn_87K
Description:
Obtain the digital input value from I-87K series modules.
Syntax:
DigitalIn_87K (DWORD dwBuf[], float fBuf[], char szSend[], char szReceive[])
Input Parameter:
dwBuf:
fBuf:
szSend:
szReceive:
DWORD Input/Output argument table
Float Input/Output argument table
Command string to be sent to I-87K series modules.
Result string receiving from I-87K series modules.
Return Value:
NoError:
Others:
OK
Error code
dwBuf: DWORD Input/Output Table
dwBuf[0] :
dwBuf[1] :
dwBuf[2] :
dwBuf[3] :
dwBuf[4] :
COM port number, 1 to 255
Module address, from 0x00 to 0xFF
Module ID, 0x87054/55/56/57/60/63/64/65/66/68
0=checksum disable, 1=checksum enable
Time out setting, normal=100, unit=ms.
dwBuf[5] :
dwBuf[6] :
16-bit digital input data
0 Æ no save to szSend & szReceive
1 Æ save to szSend & szReceive
fBuf: Float Input/Output Table
Not used
DCON DLL user’s Manual, 2003 June, Ver. 3.5, 7MS-018-35------ 88 -