Download UM08010-R3 User Manual J-Link JTAG Isolator Introduction Power

Transcript
User Manual for J- Link JTAG I solat or 1/ 4
UM 0 8 0 1 0 - R3
Use r M a n u a l
J- Link JTAG I solat or
Introduction
The J- Link JTAG I solat or can be connect ed bet ween J- Link ARM and any ARMboard t hat uses t he st andard 20- pin JTAG- ARM connect or t o provide elect rical
isolat ion. This is essent ial when t he developm ent t ools are not connect ed t o
t he sam e ground as t he applicat ion. I t is also useful t o prot ect t he
developm ent t ools from elect rical spikes t hat oft en occur in som e applicat ions,
such as m ot or cont rol applicat ions.
A 20- pin flat cable ( supplied wit h J- Link) is needed t o connect t he t arget .
Power supply
Bot h sides, t arget and em ulat or, are t ot ally isolat ed and separat ely powered.
The t arget side draws power from pins 1 or 2, t he em ulat or side draws power
from pin 19.
Figur e 1 .
J- Link JTAG I sola t or
Re se t LED
Ta r ge t
side
Em u la t or
Side
( J- Link )
Pow e r LED
Pow e r LED
Features
•
•
•
•
•
•
•
1kV DC isolat ion
3.3V and 5V t arget operat ion support ed
Powered from em ulat or and t arget
JTAG st andard 20- pin connect ion support ing TRST, TDI , TMS, TCK, RTCK,
TDO and RESET signals
Power consum pt ion on t arget side: < 50m A
JTAG frequency: Up t o 4MHz
3 LEDs t o indicat e em ulat or power, t arget power and t arget RESET
 2008 SEGGER Microcont roller Gm bH & Co. KG
User Manual for J- Link JTAG I solat or 2/ 4
Connectors and indicators
The I solat or uses high speed opt ocouplers t hat allow a very low propagat ion
t im e bet ween input and out put . I t com es wit h t he following connect ors and
indicat ors:
• 20- pin fem ale EMULATOR connect or which can be plugged direct ly int o JLink
• 20- pin m ale TARGET connect or for connect ion of t he t arget cable
• Green LED indicat ing power on t he em ulat or side
• Green LED indicat ing power on t he t arget side
• Red LED indicat ing RESET
Block diagram
The funct ional block diagram ( Figure 2) illust rat es t he funct ional connect ions
bet ween t he em ulat or and t arget .
Figu r e 2 .
Fu n ct iona l block dia gr a m
POWER
POWER
GND_E
GND_T
RESET
RESET
GND_E
TRST
TRST
EMULATOR
GND_E
TDI
TARGET
TDI
GND_E
TMS
TMS
GND_E
TCK
TCK
GND_E
RTCK
RTCK
GND_T
TDO
GND_E
TDO
GND_T
GND_T
 2008 SEGGER Microcont roller Gm bH & Co. KG
User Manual for J- Link JTAG I solat or 3/ 4
Connecting the Isolator to Target and Emulator
Figu r e 3 .
Con n e ct in g t he I sola t or t o Ta r ge t a n d Em u la t or
Isolator
VCC
1
2
VCC
nTRST
TD I
3
4
5
6
GN D
GN D
TM S
TCK
7
9
Flat cable
CPU
GN D
10 GN D
8
RTCK
11
12
TD O
RESET
13
14
15
GN D
16 GN D
N/ C
N/ C
17
18
19
J-Link
Target
GN D
GN D
20 GN D
Isolator
J-Link
Target
Flat cable
CPU
The Em ulat or side of t he I solat or is plugged direct ly int o t he Em ulat or. The
Target side is connect ed t o t he t arget via a 20- pin flat cable.
Using the Isolator with J-Link
I n order t o use t he I solat or, follow t hese st eps:
•
•
•
•
•
Plug t he I solat or direct ly int o J- Link.
Power J- Link.
Make sure t he green LED on t he em ulat or side is lit . I f it is not , follow t he
inst ruct ion in t he next sect ion.
Connect t he t arget via 20- pin flat cable t o t he t arget side of t he I solat or.
I f t he t arget is powered, t he green LED on t he t arget side should be lit .
The red LED on t he t arget side is lit when a Target RESET is act ive ( low) .
Preparing J-Link to supply power
J- Link needs t o supply 5V power t o t he em ulat or side of t he adapt er on pin 19.
I n order t o do t his, you m ay have t o configure J- Link once as follows:
• Make sure t hat SEGGER J- Link soft ware is inst alled on your m achine.
I t can be downloaded from ht t p: / / www.segger.com / download_j link.ht m l
• St art J- Link Com m ander, which can be found under “ Start -> Programs > SEGGER -> J-Link ARM”
• Ent er t he following com m and: power on perm
• Plug in t he adapt er: The LED on t he em ulat or side should now be lit .
Using the Isolator with an other ARM emulator
The I solat or has been designed for J- Link, but can also be used wit h ot her ARM
em ulat ors wit h t he sam e pin- out . I n t his case, you should m ake sure t hat 5V
are supplied t o pin 19 of t he em ulat or connect or and t hat your em ulat or is not
dam aged when applying 5V t o t his pin. D o t his a t you r ow n r isk !
 2008 SEGGER Microcont roller Gm bH & Co. KG
User Manual for J- Link JTAG I solat or 4/ 4
Disclaimer
Specificat ions writ t en in t his docum ent are believed t o be accurat e, but are not
guarant eed t o be ent irely free of error. The inform at ion in t his m anual is
subj ect t o change for funct ional or perform ance im provem ent s wit hout not ice.
Please m ake sure your m anual is t he lat est edit ion. While t he inform at ion
herein is assum ed t o be accurat e, SEGGER Microcont roller Gm bH & Co. KG
( t he m anufact urer) assum es no responsibilit y for any errors or om issions. The
m anufact urer m akes and you receive no warrant ies or condit ions, express,
im plied, st at ut ory or in any com m unicat ion wit h you. The m anufact urer
specifically disclaim s any im plied warrant y of m erchant abilit y or fit ness for a
part icular purpose.
Copyright notice
You m ay not ext ract port ions of t his m anual or m odify t he PDF file in any way
wit hout t he prior writ t en perm ission of t he m anufact urer.
2008 SEGGER Microcont roller Gm bH & Co. KG, Hilden / Germ any
Trademarks
Nam es m ent ioned in t his m anual m ay be t radem arks of t heir respect ive
com panies.
Brand and product nam es are t radem arks or regist ered t radem arks of t heir
respect ive holders.
Contact address
SEGGER Microcont roller Gm bH & Co. KG
I n den Weiden 11
D- 40721 Hilden
Germ any
Tel.+ 49 2103- 2878- 0
Fax.+ 49 2103- 2878- 28
Em ail: support @segger.com
I nt ernet : ht t p: / / www.segger.com
Revisions
Re vision
0
1
2
3
Date
080104
080109
080118
080827
By
OO
OO
OO
OO
Ex pla n a t ion
I nit ial version
Added / updat ed pict ure for bet t er underst anding.
Updat ed Figure 2 “ Funct inal block diagram ”
Minor changes
 2008 SEGGER Microcont roller Gm bH & Co. KG