Download Foreword
Transcript
NICE2000 User Manual Installation and Wiring Sort Terminal Terminal sign name Function instruction 2. Output voltage specification:0~10V 3. Output current specification:0~2mA DO1-CNICE Analogue output Optocoupler isolation, double polarity open circuit collector output type. Output voltage specification :0~24V Output current specification :0~50mA Digit Note: CME and COM is isolated inside, output FM-COM but CME and COM have jump out (DO1 Reservation default: +24V driven); when DO1 wants to use exterior power drive, the outside jumper between CNICE and COM function setup should be cut off. Normal close T/A-T/B Relay output Normal open T/A-T/C Terminal PG card 3. output Y12, Outside-bring keyboard keyboard, parameter-copy-unit interface I/O extend board terminal configuration CM1 Y1 Y2 RX- RX+ CM2 X 1 30V, 1A Relay PG card special interface Outside bring CN3 250V, 3A, Cosφ=0.4 DC : 28-core terminal, special interface card expansion card J2 interface AC : determined by F5-12 parameters. Function J1 Auxiliary Contact driving capacity: Terminal X 2 X 3 X 4 X 5 Y3 Y4 Y9 X 6 X 7 Y10 X 8 Y5 Y6 Y7 Y8 Y11 X 9 X 10 X 11 X 12 X 13 X 14 DC + D C- 4. Function instruction of I/O expansion board terminal Sort Power supply Sign DC+~DC- Name Function instruction External connect +24V power NICE2000 adopts exterior +24V power, usually used as digit input terminal work power. ‐ 27 ‐