Download Shallow Borehole EpiSensor
Transcript
DOCUMENT 301934, REVISION B 2. Installation This chapter contains information relevant to the installation of the SBEPI unit. Our Services Group can provide additional expertise and borehole services. This chapter covers the following information: Accessory Kit Electrical Connection Functional check and zero offset measurement Accelerometer adjustment SBEPI installation Accessory Kit The SBEPI is shipped with the following accessories. These items are required for installation of the unit. Please contact Kinemetrics for replacement kits. Table 1: Accessories Kinemetrics P/N Quan. Item Purpose 110393 1 Allen wrench Tool for adjusting the zero offset 700281-142 2 O-ring Seals the sensor to the main housing 870513 2 Backup Ring Seals the sensor to the main housing 110582 1 Spanner wrench Tool for opening unit 700403 2 Desiccant Maintain Humidity Free Interior Inspecting the Cable End Before lowering the instrument into its hole, inspect the unit and the cable end, make sure the cable insulation is not damaged Test the unit by making the electrical connections as follows: SHALLOW BOREHOLE EPI USER GUIDE 5