CHAPTER 11 TROUBLESHOOTING 11.4 Error Code List If the following errors occur on the A/D converter module while data is written to or read from the CPU module, the corresponding error code below is stored in Latest error code (Un\G19). The error is reported to the CPU module also. Error code Description and cause of error (decimal) The input range is set with a value outside the setting range for 10 Switch 1 of the intelligent function module switch setting. The channel with the invalid setting fits in . 11 Action Set a valid value on the intelligent function module switch setting in the parameter setting. Power off and on the module. 111 A hardware failure has occurred on the module. If the error occurs again, a failure might have occurred on the module. Please consult a local Mitsubishi representative. 112 A value other than 0 is set to Switch 5 on the intelligent function Set 0 to Switch 5 on the intelligent function module module switch setting. switch setting in the parameter setting. Check the digital output value. 113*1 The data in the flash memory has a problem. If there is a problem of the digital output value, please consult a local Mitsubishi representative. Start over the offset/gain setting of all channels 120*1 An invalid value is set to the offset/gain setting. The channel where the error has occurred cannot be identified. where the user range setting is used. If the error occurs again, a failure might have occurred on the module. Please consult a local Mitsubishi representative. Start over the offset/gain setting of the channel An invalid value is set to the offset/gain setting. The channel where the error has occurred fits in . where the error has occurred. If the error occurs again, a failure might have occurred on the module. Please consult a local Mitsubishi representative. 161*1*2 The G(P).OGSTOR instruction was executed in the offset/gain Do not execute the G(P).OGSTOR instruction in the setting mode. offset/gain setting mode. • The G(P).OGSTOR instruction has been consecutively 162*1 executed. • For the offset/gain setting, a setting value has been consecutively written to the flash memory more than 25 times. • The G(P).OGSTOR instruction has been executed on a module different from the one on which the G(P).OGLOAD 163*1 instruction was executed. • The G(P).OGSTOR instruction has been executed ahead of the G(P).OGLOAD instruction. 170*1 per module. • Write the setting value into the flash memory only once for each offset/gain setting. • Execute the G(P).OGLOAD and G(P).OGSTOR instructions to the same module. • After executing the G(P).OGLOAD instruction on the module from where data is restored, execute the G(P).OGSTOR instruction on the module to where the data is restored. The offset/gain setting was configured exceeding the maximum No more offset/gain setting is reflected on the number of times. operation successfully. When Channel change request (YB) turns on in the offset/gain 171*1 • Execute the G(P).OGSTOR instruction only once setting mode, a value other than User range setting (uni-polar: current) or User range setting (bi-polar: voltage) is set in the input range setting. Set User range setting (uni-polar: current) or User range setting (bi-polar: voltage) in the input range setting. The averaging time value set in CH Time Average/Count Average/Moving Average/Time lag filter constant (Un\G1 to 20*1 Un\G4) is outside the range of 2 to 5000ms. The channel where the error has occurred fits in . Set the averaging time to a value within the range of 2 to 5000ms. 221 11.4 Error Code List 12 *1