Download Galvos specs
Transcript
GMAX M2/M2T 9.5mm XY Open Frame Head 4.2.2.6 Current Cutoff Circuit The circuit described below is sensitive to RMS current only and not coil temperature. It is essential that the user perform the above calculations to prevent malfunction or damage to the scanner. WARNING Should the current cutoff circuit cause the scanner to operate intermittently the user should cease operation immediately and review his input drive command. There is a current cutoff circuit on each driver board which calculates RMS current in the scanner coil and disconnects the driver when the current exceeds 1.7 amps RMS (square wave input) and 1.42 amps RMS (sine wave) steady state for 30 seconds. The power permitted at these currents must be calculated using the coil resistance at the galvo operating temperature. The power at room temperature (25 °C) is calculated using a coil resistance of 4.65 ohms. At 100 °C, the power is calculated using a coil resistance of 6.05 ohms. Since the circuit has a built in delay, the current may exceed these values for periods of time shorter than 30 seconds. For instance, the circuit will permit 2.13 amps (square wave) for 13 seconds. This circuit should prevent coil damage under most long-term over power situations, but does not eliminate the possibility of damage due to brief fault conditions involving significantly higher currents. In summary, this circuit will not prevent damage due to unusual fault conditions during tuning or system debug. 15