[Unit]
Access
Default
Min
Max
Format
Reg. Mode
TRAVEL / DC braking
DC current injection can help to stop the motor and ensure that lift car arrives exactly at floor level.
1836
DCbrake cmd src
N/A
RWS
IPA 7125
List 3 PIN
V-F-S-B
IPA 7125 Lift DC Brake mon = Default
It allows to select the origin of the signal to command DC braking function, normally if is controled by lift
sequence. (refer to signals List 3 of Pick List manual)
1833
DCbrake delay
[sec]
RWS
0.1
0.01
30
PP
Delay between the injection command and the injection of the current itself
V-F-S-B
1834
DCbrake duration
[sec]
Duration of the current injection
1835
1837
30
PP
V-F-S-B
DCbrake current
[%]
RWS
100
0
Braking current as a percentage of Drive continuos current
100
PP
V-F-S-B
DCBrake state
N/A
0
non-active
1
active
State of DC Brake functon.
1
DV
V-F-S-B
NOTE!
RWS
R
1
0
0.01
0
Sequence available only when IPA 7105 set as Start fwd/rev.
Lift DC brake mon signal that controls DC current braking is not available.
Speed ref
Speed 0 ref thr
t
DC brake cmd src
Speed 0 ref dly + Brake close dly
Lift DC brake mon
Output current
DC brake
delay
DC brake
duration
A
DC brake current
B
DC brake state
1
0
A
=
DC brake delay + DC brake duration > Spd 0 ref dly + Brake close dly
B
=
DC brake delay + DC brake duration < Spd 0 ref dly + Brake close dly
148 • Chapter 9 Parameter
ARTDriveL Instruction Manual