VME-A24SA [<val>]
VME A24 compare address (default: 0x00)
Defines the slave address of the B5 in A24 mode:
7
6
5
4
0
0
0
0
3
2
1
0
A23..A20
These bits are compared with VMEbus lines A23..A20.
Do not enter odd numbers!
Slave access cannot be disabled!
Note: When the EEPROM contents are modified, the new parameters will have no
effect until the system is restarted.